• Title/Summary/Keyword: application test

Search Result 9,405, Processing Time 0.036 seconds

A Study on the Effect of Cooperative Computer-Assisted Instruction by Previous Achievement Level (사전 성취 수준에 따른 협동적 컴퓨터 보조 수업의 효과)

  • No, Tae-Hui;Cha, Jeong-Ho;Yun, Seon-Ae;Gang, Seok-Jin
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.377-384
    • /
    • 2002
  • In this study, the effect of cooperative computer-assisted instruction upon students' conceptual under-standing,application ability, and learning motivation were investigated by a previous achievement level. The treatment and the control groups (2 classes) were selected from a middle school in Seoul, and taught about the motion of molecule for 5 class periods. Prior to the instructions, a learning motivation test was administered and used as covariate. The scores of a previous achievement test were also used as covariate. The scores of the mid-term science examination were used as blocking variable. After the instructions, the conceptions test, the application test, and the learning motivation test were administered. Two-way ANCOVA results revealed that there were no significant differences in the scores of the con-ceptions test and the application test. However, the scores of the treatment group were found to be significantly higher than those of the control group in the learning motivation test.

VALIDATION AND UTILIZATION OF THE SKINTEXTM SYSTEM

  • Gordon, V.C.;Realica, B.;Tolstrup, K.;Puls, B.
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.17 no.1
    • /
    • pp.64-80
    • /
    • 1991
  • The SKINTEX Method is based on a two-compartment physico-chemical model which includes a Biomembrane Barrier in compartment one and an organized macromolecular matrix in compartment two. Test samples absorb onto or permeate through the keratin/collagen Biomembrane Barrier and then can interact with the organized macromolecular matrix. Changes in the integrity of the barrier release a dye indicator: Changes in the matrix can alter its transparency. The sum of these two responses is read spectrophotometrically at 470nm. An early investigation of 950 chemicals and formulations in the SKINTEX System produced results which were 89% concordance to in vivo Draize dermal irritation results obtained with 24-hour occluded application of test samples with-out abrasion and standard scoring. Alkaline materials were analyzed in a specialized SKINTEX AMA Protocol. In this early study, the model did not distinguish nonirritant test materials and formulation with PDII(Primary Dermal Irritation Index)in the range from 0 to 1.2, A High Sensitivity Assay Protocol(HSA)was developed to amplify the changes in both compartments of this model and provide more accurate calibration of these changes. A study of 60 low irritation test samples including cosmetics, household products, chemicals and petro-chemicals distinguished nonirritants with PDII $\leq$ 0.7 for 26 of 30 nonirritants. A second protocol was developed to evaluate the SKINTEX model predictability with respect to human irritation. The Human Response Assay (HRA )has been optimized based on differences in penetration and irritation responses in humans and rabbits. An additional 32 test materials with different mechanisms and degrees of dermal toxicity were evaluated by the HRA. These in vitro results were 86% concordant to human patch test results. In order to further evaluate this model, a Standard Chemical Labelling (SCL) Protocol was developed to optimize this system to predict Draize dermal irritation results after a 4-hour application of the test material. In a study of 52 chemicals including acids, bases, solvents, salts, surfactants and preservatives, the SCL results demonstrated 85% concordance to Draize results for a 4-hour application of test samples on non-abraded rabbit skin. The SKINTEX System, including three specialized protocols, provided results which demonstrated good correlation to the endpoint of dermal irritation in man and rabbits at different application times.

  • PDF

Geotechnical Characteristics and Field application of Soil Mixed with Waste Lime (부산석회 혼합토의 지반공학적 특성 및 현장 적용 사례)

  • 정하익;홍승서;김상근;홍성완;유홍기;임병익
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.217-222
    • /
    • 2003
  • This study was carried out to investigate the geotechnical characteristics and field application of soil mixed with waste lime. Waste lime used in this study is producted as a by-product in the manufacturing process of making Na$_2$CO$_3$from local chemical factory in Incheon. Currently about 320 milton tons of waste lime are accumulated and annually 100,000 tons are producted. In this study, feasible use of waste lime mixed with granited whathered soil, clay, crushed rock was invesigated through laboratory tests including specific gravity test, sieve analysis, hydrometer analysis, compaction test, CBR test. Field investigations were conducted on the road construction site in Incheon.

  • PDF

Traction System Combined Test of KHST for Propulsion System Performance Verification (한국형 고속전철 추진성능 검증을 위한 추진시스템 통합시험)

  • Ryoo H.J.;Kim J.S.;Kim Y.J.;Knoh A.S.;Jung E.S.;Choi J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.886-890
    • /
    • 2003
  • This paper introduces the combined test results of the traction system for KHST(Korean High Speed Train: hereafter refer to KHST). The main purpose of this combined test is to verify the performance of the traction system that is designed to operate up to maximum 350km/h speed. Combined test system consists of a traction transformer, two AC-DC PWM converters, a PWM Inverter, two traction motors and flywheel system. Flywheel system represents equivalent model of the train inertia. Also traction control system and MASCON Interfaces are included. Various kinds of experiments are performed to prove total traction system performance and detail waveforms are described

  • PDF

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

ETRI Protocol Test Architecture and Its Application to CCS Network Service Part Protocols (ETRI 프로토콜 검증구조와 CCS망 서비스부 프로토콜에의 응용)

  • Gang, Yeong-Man;Cheon, Dae-Nyeong;Cha, Yeong-Hwan;Baek, Yeong-Sik;Choe, Yang-Hui
    • ETRI Journal
    • /
    • v.10 no.2
    • /
    • pp.3-12
    • /
    • 1988
  • Several ISDN (Integrated Services Digital Network) protocols have implemented at ETRI (Electronics and Telecommunications Research Institute) in an experimental network so that functional characteristics of the protocols under test could be certified against their protocol specifications with the help of the ETRI protocol test facilities. This paper describes ETRI protocol test architecture and its application to testing the NSP (Network Service Part) protocols : MTP (Message Transfer Part) level 3 and SCCP (Signalling Connection Control Part) of the CCITT CCS (Common Channel Signalling ) system No. 7 The test architecture presented here allows tests for two different protocol classes : peer-to-peer and multipeer protocolos. Some extensions are made to the conventional test architectures, namely the test coordination, test result transfer and network state observation method.

  • PDF

A STUDY ON THE APPLICATION OF FIELD TESTS TO WEAK GROUND (연약지반에 대한 현장시험 적용에 관한 연구)

  • Lee, Seung-Rae;Jeong, Han-Jung;Kim, Jun-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.10a
    • /
    • pp.145-148
    • /
    • 1992
  • This paper reports the application of field tests to weak ground. In this study, field and laboratory tests were performed in the west seashore of KOREA(Ildo, Sore, Kunsan, Youngam). Applied tests are standard penetration test, cone penetration test, dilatometer test, field vane test, unconsolidated undrained test, oedometer test and other fundametal material properties tests. The results of in-situ test are used to estimate soil types and undrained shear strengths of five clay local deposits. SPT results showed low reliability and FVT war also demonstrated the best field test to weak clayey deposits.

  • PDF

AN ANALYSIS OF LEARNING ABILITY IN CALCULUS BASED ON THE SELECTION OF TEST AREAS IN THE COLLEGE SCHOLASTIC ABILITY TEST

  • RHEE, HYANG JOO
    • Korean Journal of Mathematics
    • /
    • v.23 no.4
    • /
    • pp.643-654
    • /
    • 2015
  • This study analyses the cross-application system, one of the diversified college admission processes, based on the entrance examination system by the reorganization of the education curriculum. In addition, this study suggests an improvement direction of mathematics education for students who cross-apply by comparing and analysing academic results in Calculus for those students entering universities through the cross-application system.

Durablity Test and Field Application of Marine Concrete (항만콘크리트의 내구실험과 현장적용)

  • 강희철;정원기;이규정;박우선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.676-681
    • /
    • 2000
  • This paper covers durability and field application of marine concrete which have been enhanced the resistance against deterioration in seawater. Fly ash concrete is applied to make the concrete with good durability. It is well known fly ash in concrete has a good performance preventing fro a sulphate attack and a steel corrosion. Several durability tests were performed to find characteristics of marine concrete which is proposed in this paper comparing with normal concrete. Field application was executed to compare results with laboratory test and to give a reliability to engineers. The project was supported by Ministry of Marine Affairs and Fisheries for two years.

  • PDF