• 제목/요약/키워드: antenna measurement

검색결과 746건 처리시간 0.039초

GPS를 이용한 자세결정에서 Unscented Kalman Filter를 이용한 성능 향상 (Performance Improvement in GPS Attitude Determination Using Unscented Kalman Filters)

  • 천세범;이은성;강태삼;지규인;이영재
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.621-626
    • /
    • 2005
  • With precise GPS carrier positioning result, we can get attitude information if GPS antenna has adequate attaching position on the vehicle. In this case, baseline length information can be bandied as an additional measurement or constraint. In this paper, we have proposed a method to improve the attitude accuracy. To overcome nonlinearity of baseline observation model, we analyze attitude estimation result using existing estimation method like a least square method and Kalman filter, and apply a new nonlinear estimation method an unscented Kalman filter Finally we confirm the improvement of attitude estimation result in the case of appling the unscented Kalman filter.

다중경로페이딩 경감을 위한 원편파 다이버시티 시스템 제작 및 성능 평가 (The Fabrication and Performance Estimation of Circularly Polarization Diversity System for Multipath Fading Reduction)

  • 이주현;김판신;안재성;김태홍;고연화;김흥진;하덕호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.609-612
    • /
    • 2003
  • For combating multipath fading in wireless radio environment, diversity schemes is useful. In this paper, for performance improvement of polarization diversity system, we analyzed a two-branch polarization diversity at the receiving end of a mobile link when the transmitter emits a circularly polarized wave. And In order to calculate the correlation coefficient considering the XPD(cross polarization discrimination) between the received signals for the two diversity branches, a simple theoretical model of circular polarization diversity is adopted and calculate correlation coefficient. From the analysis results, it is seen that the correlation coefficient of circular polarization diversity evaluated by the XPD is less than that of vertical polarization diversity. And also, we designed and fabricated circular polarization diversity system with microstrip antenna. we analyzed data measured in indoor NLOS environment using fabricated circular polarization diversity system. From the measurement results, it is clearly seen that the diversity effect of circular polarization diversity system is higher 3dB than vertical polarization diversity system.

  • PDF

방사전자파의 주파수분석에 의한 배전반 진단기술 (Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave)

  • 박대원;김선재;정광석;길경석;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

측정 Array Manifold를 적용한 입사 신호의 공간 스펙트럼 추정 (Spatial Spectrum Estimation of Incident Signal Via Measured Array Manifold)

  • 강흥용;이성윤;김영수;김창주;박한규
    • 한국전자파학회논문지
    • /
    • 제15권3호
    • /
    • pp.223-230
    • /
    • 2004
  • 입사 신호에 대한 배열 안테나의 응답인 array manifold를 측정에 의해 생성하는 방법을 기술하였으며, 기술된 방법에 의해 실측된 등간격 원형 배열 안테나의 array manifold를 MUSIC 알고리즘에 적용하여 배열 안테나로 입사되는 300 MHz tone 신호의 공간 스펙트럼을 추정하였다. 측정 array manifold를 이용한 공간 스펙트럼 추정은 이상적인 배열 안테나를 가정한 계산 array manifold 대비 월등한 성능을 보인다.

절연진단을 위한 기중방전에서의 방사전자파 측정과 분석 (The Measurement and Analysis The Electromagnetic Wave by Discharge in Air for Insulation Diagnosis)

  • 이상훈;이현동;이춘하;윤영대;김기채;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.141-144
    • /
    • 1999
  • This paper offer fundamental ones about insulation diagnosis with electromagnetic wave, when discharges occurred. To simulate Partial-Discharge(PD), It is used needle-plane electrode in air. As the voltages applied, measure the electromagnetic wave with monopole antenna and analysis its fundamental characteristics, then, acquired data were operated. The results presented as the form of graph, and the magnitude of charge when occurred PD simultaneously. In conclusion, when the magnitude of charge over 100[pC], the electric field strength changed, and then the magnitude of charge and the electric field strength increased samely.

  • PDF

기중방전 진전에 따른 방사전자파의 주파수 스펙트롬 특성 (The Characteristic of Frequency Spectrum of Electromagnetic Waves Radiated from Discharge in Air)

  • 박광서;윤대희;박창기;주재현;최병주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.285-289
    • /
    • 1999
  • Insulation diagnosis techniques of power equipments for the stable power supply and prevention from accidents are of high importance. Diagnosis techniques is able to prevent from large accidents before they happen by finding signs of the accidents. From this point of view, this paper simulated discharge progress and partial discharge using needle-plan electrode system in air, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study, the new method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with discharge progress in air, Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

  • PDF

The improvement of cut-off probe for measuring plasma density at hard conditions

  • 김대웅;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Diagnostics of plasma density is a key factor for monitoring plasma processing. Various probes are invented to measure plasma density and cut-off probe is a one of the most promising diagnostics tool for measuring plasma density. However, at the low density or high pressure the cut-off probe cannot clearly resolve the cut-off peak. Several reasons make this problem: Cut-off likes peaks caused by cavity resonances and weaken transmission spectrum signal at high pressure. Recently, You et al., have researched mechanism of cut-off probe and we improve the cut-off reliability and sensitivity base on that research. Modified cut-off antenna is adapted and bias cut-off probe method is tried. These experiment results have good agreement with the previous study and show good measurement characteristics.

  • PDF

Lynx Mobile Mapper를 이용한 레이저스캐너 기반 차량 MMS의 캘리브레이션 (Calibration of Laser scanning Mobile Mapping System using Lynx Mobile Mapper)

  • 정태준;윤홍식;황진상;김용현;이하준
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.207-208
    • /
    • 2010
  • In this paper, we carried out calibration of laser scanning MMS(Mobile Mapping System) using Lynx Mobile Mapper, a new MMS developed at Optech Incorporated. Laser scanning MMS could be defined as an integration of several subsystems. Subsystems are composed of laser scanner, gps receiver and antenna, INS(Inertial Navigation System), DMI(Distance Measurement Instrument). These are obtained 3D spatial information by direct-georeferencing technology. To obtain 3D spatial information, calibration of laser scanning MMS is required prior to operation system, it is similar to airborme lidar system. 145 checkpoints were used to accuracy estimation. The accuracy results are about 5cm(RMSE) for calibration in all directions(east, north, ellipsoidal height).

  • PDF

연속파 테라헤르츠 포토믹수를 위한 폴디드 공진 안테나 (Resonant Folded Dipole Antennas for Continuous-Wave Terahertz Photomixer)

  • 문경식;박홍규;김정회;정은아;이경인;한해욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.181-182
    • /
    • 2006
  • Photoconductive three-wire folded dipole antennas for terahertz photomixers have been developed. The folded antennas are characterized by a free space time-domain measurement technique, and the measured data are in good agreement with the simulation results. The folded dipole antennas have much higher antenna resistance than other resonant dipole antennas, implying that they can be used for higher output power of THz photomixers.

  • PDF

LC 공진을 이용한 원격측정용 실리콘 압력센서 (Telemetry Silicon Pressure Sensor Using LC Resonance)

  • 김순영;박진성;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2254-2256
    • /
    • 2000
  • This paper presents an implantable telemetry LC resonance-type pressure sensor for the measurement of the ventricle pressure. This sensor consists of a capacitor and an inductor. This resonant circuit is magnetically coupled with an external antenna coil. The resonance frequency of the circuit decreases as the sensor capacitance is increased by the applied pressure. The inductance and the capacitance are 428nH and 0.98${\mu}F$, respectively. The resonance frequency is 245.7MHz when the differential pressure is zero. The sensitivity of the sensor is 9.477kHz/Pa.

  • PDF