• Title/Summary/Keyword: antenna measurement

Search Result 750, Processing Time 0.025 seconds

Design of a 0.5~2 GHz Cavity-Backed Spiral Antenna (0.5~2 GHz 캐비티 백 스파이럴 안테나 설계)

  • Jeon, Nam-Du;Shin, Dong-Hoon;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.269-277
    • /
    • 2010
  • In this paper, the design of a 0.5~2 GHz cavity-backed spiral antenna is described. Combined arm pattern with a log spiral in the inner region and an Archimedean spiral in the outer region, a backing cavity, and a Marchand coaxial balun for feeding are designed. Termination resistors are used to improve antenna characteristics at the lower frequency of the operation frequency. VSWR, axial ratio, gain and HPBW(Half Power Beam Width) characteristics are simulated using CST's MWS. Finally, the validity of these approaches is verified by comparing the simulated results with the measured ones. Also, the measurement results are compared with the performance of a commercial spiral antenna.

Development of Microstrip Antenna for Satellite Broadcasting Receptions Based on the Sierpinski Equilateral Triangular Patch and SSFIP (slot­strip­foam­inverted patch) structures (Sierpinski 프랙탈 구조를 가지는 정삼각형 패치와 SSFIP 구조에 의한 위성방송 수신용 마이크로스트립 안테나의 개발)

  • 심재륜
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1598-1603
    • /
    • 2003
  • A microstrip array antenna is designed and tested for satellite broadcasting receptions. The Sierpinski equilateral triangular patch and SSFIP(slot­strip­foam­inverted patch) structures are used. The Sierpinski geometry is composed of 3 equilateral triangular patch and is easy to generate a circular polarization by sequential rotation array techniques. This 1${\times}$3 Sierpinski equilateral triangular patch antenna is extended to 8${\times}$2 array antenna for satellite broadcasting receptions. The measurement results of the reflection coefficients and the radiation patterns of the manufactured array antenna show good agreements with the simulation results.

A Study on the Characteristic Analysis of Passive Intermodulation among Highpower Radiostations (고출력 무선국간의 수동 상호변조시 특성분석에 대한 연구)

  • Kim Yung-Duk;Jo Hak-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.176-179
    • /
    • 2006
  • As spurious emission strength is normally measured at the antenna feeder, It is required that the measurement method on passive Intermodulation occurred on the latter part of antenna feeder be made. through the tests and the analyses of passive Intermodulation between radiostations of adjacent frequency bands, the possibility of occurrence of passive Intermodulation was testified in this study. The purpose of this study is to propose the measurement method of spurious emission strength in order to prevent the bad effect by passive Intermodulation.

Feasibility Study for the Development of a Device for Detecting Pathological Tissues (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko, Chea-Ok;Park, Min-Young;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.421-424
    • /
    • 2005
  • X-ray is currently most effective method in detecting small malignant breast tumors but has the several problems due to suppressing breast, ionizing radiation and not detecting small cancer. In this paper, a new method is proposed by using dielectric characteristics of pathological tissues and time delay of backscattered response. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna is a key element of such detection system. Further study is ongoing to develop a commercial system.

  • PDF

Measurement of Transient Electric Field Emission from a 245 kV Gas Insulated Substation Model during Switching

  • Rao, M. Mohana;Thomas, M. Joy;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.306-311
    • /
    • 2007
  • The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

A Study on the Partial Discharge Measurement using Antenna in Metal-Enclosed Switchgear (폐쇄형 배전반내의 안테나를 이용한 부분방전측정에 관한 연구)

  • Kim, Young-No;Lee, Young-Suk;Seo, In-Chul;Hong, Jong-Suk;Kim, Jae-Chul;Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.534-536
    • /
    • 2000
  • This paper describes measurement and diagnosis methods for enclosed switchboards using antenna. In the laboratory partial discharges are generated on a needle-plate electrode configuration, the detected electromagnetic wave is analyzed by FFT. The detected electromagnetic wave in real enclosed switchboards is also analyzed by FFT, which is compared with frequency spectra of the laboratory to detect the partial discharge. The relationship between the partial discharge characteristics and the electromagnetic wave has been discussed.

  • PDF

Analysis of Absorption Loss by a Human Body in On-to-Off Body Communication at 2.45 GHz

  • Jeon, Jaesung;Lee, Sangwoo;Choi, Jaehoon;Kim, Sunwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.2
    • /
    • pp.97-103
    • /
    • 2015
  • This paper investigates the effect of absorption loss by a human body to the received signal strength with respect to on-body transmitting antenna positions in on-to-off wireless body area networks. This investigation is based on measurement results obtained from experiments performed on human bodies (male and female) using planar inverted-F antennas in an anechoic chamber. The total absorption loss by the human body is also presented through the SEMCAD-X simulations. Our investigation showed that the received signal strength becomes lower when the transmitting antenna is mounted at a specific position where more absorption loss is experienced. The statistical analyses of on-to-off body channel characteristics based on the measurement results are presented.

Magnetic Field Strength Measurement using Circular Loop Antenna (환상 루-프 안테나를 이용한 자기장 세기의 측정)

  • 박병권;강찬구;김정환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.6
    • /
    • pp.566-573
    • /
    • 1991
  • For the evaluation of the magnetic field strengthmeasured by standard field method with that measured by standard antenna method. The compared results are in good agreement within the error limit. As the Result of this research, the calibration service for magnetic field strenth measurement can be provided whtin the uncertainty of about 1 dB in the frequency range of 10 kHz to 30MHz.

  • PDF

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • v.15 no.1
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.