• Title/Summary/Keyword: anode degradation

Search Result 117, Processing Time 0.026 seconds

Influence of Applied Electric Field on Low Temperature Degradation of Y-TZP (인가 전압이 Y-TZP의 저온열화에 미치는 영향)

  • 장주웅;이홍림;김대준;오남식;이득용
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.12
    • /
    • pp.1254-1260
    • /
    • 1997
  • Influence of applied electric field on the low temperature degradation of 3 mol% YaO3 stabilized tetragonal zirconia polycrystals(3Y-TZP) was investigated using X-ray diffractometry of specimens aged under the dc field of 1.1 kV/mm in silicone oil both of 12$0^{\circ}C$-21$0^{\circ}C$. After the aging, the tetragonal to monoclinic phase transformation was observed only on the specimen surface of 3Y-TZP faced to the anode. This indicated that the surface was overcrowded with oxygen ions as a result of diffusion of oxygen vacancies toward the cathode-sided surface. To elucidate an influence of the applying time of the electric field on the extent of the degradation of 3Y-TZP in air, specimens were aged fore 0-2 hours under the electric field in the oil bath of 12$0^{\circ}C$ and then subsequently aged for 3h at 22$0^{\circ}C$ in air. The longer the specimens were aged under the field, the more extensive the transformation to the monoclinic phase was on the specimen surface faced to the cathode, probably originated from a high diffusion rate of oxygen ions due to a steep oxygen vacancy concentration gradient.

  • PDF

Characteristic of Oxidants Production and Dye Degradation with Operation Parameters of Electrochemical Process (전기화학적 공정의 운전인자에 따른 산화제 생성과 염료 분해 특성)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1235-1245
    • /
    • 2009
  • The purpose of this study is to investigate electro-generation of free Cl, $ClO_2$, $H_2O_2$ and $O_3$ and degradation of Rhodamine B in solution using Ru-Sn-Sb electrode. Electrolysis was performed in one-compartment reactor using a dimensionally stable anode(DSA) of Ru-Sn-Sb/Ti as the working electrode. The effect of applied current (0.5-3 A), electrolyte type (NaCl, KCl, HCl, $Na_2SO_4$ and $H_2SO_4$) and concentration (0.5-2.5 g/L), air flow rate (0-3 L/min) and solution pH (3-11) was evaluated. Experimental results showed that concentration of 4 oxidants was increased with increase of applied current, however optimum current for RhB degradation was 2 A. The generated oxidant concentration and RhB degradation of the of Cl type-electrolyte was higher than that of the sulfate type. The oxidant concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.75 g/L. Optimum air flow rate for the oxidants generation and RhB degradation was 2 L/min. $ClO_2$ and $H_2O_2$ generation was decreased with the increase of pH, whereas free Cl and $O_3$ was not affected by pH. RhB degradation was increase with the pH decrease.

Remediation of Diesel-Contaminated Soil by Electrokinetically Supplied Bacterial Cells

  • 이효상;이기세
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.20-23
    • /
    • 2000
  • The use of electrokinetic injection and transport for the distribution of an NAPLs-degrading microorganism in a sandy soil bed was studied. After the injection of the cell into cathode side of bed, an electric current was applied. The transport of cell though the sandy soil was achieved by electokinetics, mainly by electrophoresis, The pH control in electrode chamber plays un important role to achieve desirable cell transport because H$^{+}$ generated at anode is toxic or inhibits the transport of cells. Electokinetic distribution rate of bacterial cells changed depending on the applied electric current and pH. The degradation of diesel by electrokinetically transport cells were monitored.d.

  • PDF

Performance change of Polymer electrode Membrane operating temperature (PEMFC 고분자 전해질막의 운전온도에 따른 성능변화)

  • Lee, Ho;Shin, Kang-Sup;Park, Kwon-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.180-182
    • /
    • 2007
  • PEMFC의 상용화 진입에 있어서 걸림돌 중의 하나가 열화(degradation)에 의한 성능감소이다. PEMFC 고분자 막의 열화가 PEMFC 성능 감소에 많은 영향을 미친다. 고분자 막의 성능 감소 원인은 여러가지가 있지만 무가습/OCV조건에서 성능 감소가 잘 된다. 그 이유에 대해서는 OCV/무가습 조건에서 과산화수소나 라디칼이 많이 형성될 수 있다는 것과, OCV조건에서 사용되지 못하는 수소와 산소의 gas-crossover 가 많기 때문이라는 것 그리고 무가습 조건에서 수소와 산소의 분압이 높아 gas-crossover 가 유리하고 악의 건조에 따른 물리적인 영향 등등이 거론되고 있다. 본 연구에서는 같은 조건에서 Cell 운전온도가 막열화에 미치는 영향을 실험하였다. OCV 여려 조건 에서 단위전지 실험을 한 후 I-V, 수소 투과도, 임피던스, FER(fluoride emission rate)등을 측정해 그 결과를 검토 분석하였다. OCV/Anode 무가습 조건이 알려진 대로 막열화 가속조건 이었음을 확인하였고, 실험 결과 Cell 운전온도가 $10^{\circ}C$증가 할 때마다 FER(fluroide emission rate)이 즉 막 열화속도가 약 2배정도 증가함을 보였다.

  • PDF

Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Plasma-Enhanced Atomic Layer-Deposited Ultra-Thin Electrolyte (플라즈마 원자층증착 초박막전해질 수소 세라믹연료전지의 초기성능 저하)

  • JI, SANGHOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.340-346
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte fabricated by plasma-enhanced atomic layer deposition method was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~52% for 30 min, which continually decreased as time increased but degradation rate gradually decreased. The open circuit voltage ratio decreased with respect time; however, its behavior was evidently different from the reduction behavior of the peak power density. The activation resistance ratio increased as ~127% for 30 min, which was almost similar with the reduction behavior of the peak power density ratio.

Improving the Stability of Series-Connected Solid Oxide Fuel Cells by Modifying the Electrolyte Composition

  • Kim, Young Je;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.159-165
    • /
    • 2021
  • YSZ based anode supported solid oxide fuel cells (SOFCs) were prepared, and two cells with different electrolyte thicknesses were connected in series for the simulation of a cell-imbalanced fuel cell stack. Pure YSZ cells in a series connection exhibited a rapid degradation when a thick electrolyte cell was operated under a negative voltage. On the other hand, ceria added-YSZ cells in a series connection were stable under similar operating conditions, and the power density and impedance were about the same as those before tests. The improved stability was due to the reduction of internal partial pressure in the electrolyte by locally increasing the electronic conduction. Thus, we propose a new protection method, i.e., the local addition of ceria in the YSZ electrolyte, to extend the lifetime of a cell-imbalanced SOFC stack.

A Study on the degradation mechanism of PAN-LiCLO$_4$ Polymer Electrolyte EC windows (PAN-LIClO$_4$ 계 고분자전해질 EC창의 열화 기구에 관한 연구)

  • 김용혁;김형선;조원일;조병원;윤경석;박인철
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.4
    • /
    • pp.223-230
    • /
    • 1997
  • Tungsten oxide and nickel oxide thin films were deposited onto ITO(Indium Tin Oxide) transparent glass by the E-beam evaporation and were used as a cathode and an anode for the EC(Electrochromic) smart window, respectively. Stoichiometric structures of the deposited films were investigated by the implementation of XPS(X-ray Photoelectron Spectroscopy) analysis and the results were $WO_{2.42}$ and $NiO_{0.44}$. This oxygen deficincy might affect affect the transparency of the thin films. The electrolyte for the EC smart windows was PAN-$LiCIO_4$ conducting polymer. EC(Ethylene Carbonate)and PC(Propylene Carbonate) were added as plasticizer to enhance ion conductivity. When the weight ratio of the EC : PC was 3 : 1, transmission difference and cycle life performance were tested. Polymer EC windows showed 40% $\Delta$T at 1.5V operating volage for 3,200 cycles. Structural degradation was observed by the SIMS(Secondary Ion Mass Spectroscopy) analysis and it was confirmed that structural degradation of polymer caused by the solvent evaporation was the main cause to degrade EC smart windows.

  • PDF

Durability Evaluation of Cathode Open-type Proton Exchange Membrane Fuel Cells Stacks (Cathode 개방형 고분자연료전지 스택 내구성 평가)

  • Yoo, Donggeun;Kim, Hyeonsuck;Oh, Sohyeong;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Cathode open-type PEMFC (Proton Exchange Membrane Fuel Cells) stacks, which are widely used in small transport-type PEMFC, have a problem with poor durability. Through the accelerated durability test of the 13-cell PEMFC stack, we tried to find the cause of the degradation of the stack and to contribute to the improvement of the durability of the cathode open stack. A hydrogen/air boundary is formed during start-up/shut-down (SU/SD) due to the structural problem of the cathode open stack in which the cathode is open to the atmosphere and it is difficult to maintain airtightness, thereby deteriorating the cathode. In this study, it was possible to evaluate the durability in a relatively short time by reducing the 54% of the initial performance by repeating SU/SD 1,800 times on the cathode open stack. After dismantling the stack, each cell was divided into two and the performance was analyzed. Overall, the anode outlet MEA, which facilitates air inflow, showed more severe electrode deterioration than the inlet MEA, confirming that the hydrogen/air boundary formation during SU/SD is the main cause of degradation.

Degradation of MEA and Characteristics of Outlet Water According to Operation Condition in PEMFC (고분자 전해질 연료전지 구동 조건에 따른 MEA 열화 및 배출수 특성)

  • Hwang, Byungchan;Lee, Sehoon;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.478-482
    • /
    • 2017
  • Humidity control of proton exchange membrane fuel cell(PEMFC) is very important control condition during driving. In terms of water management, low humidification conditions are advantageous, and high humidification is advantageous in terms of drainage utilization and energy efficiency. In this study, the characteristics of outlet water in low humidification and high humidification process were studied in terms of utilization of discharged water. Since the impurities in the effluent are generated during the degradation of the membrane and the electrode assembly(MEA), degradation of the MEA under low humidification and high humidification conditions was also studied. The rate of radical generation was high at low humidification condition of the anode RH 0%, which showed that it was the main cause of the degradation of the polymer membrane. Analysis of effluent showed low concentration of fluoride ion concentration of about 20 ppb at high humidification (both electrodes RH 100%) and 0.6 V, which was enough to be used as the feed water for electrolysis. Very low concentration of platinum below 0.2 ppb was detected in the condensate discharged from the high humidification condition.

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(I) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(I))

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.49-60
    • /
    • 2009
  • Fabrication and oxidants formation of 1 and 2 component metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru, Pt, Sn, Sb and Gd) were used for the 1 and 2 component electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1 h. The removed RhB per 2 min and unit W for one component electrode decreased in the following sequences: Ru/Ti>Sb/Ti>Pt/Ti>Gd/Ti>Sn/Ti. The concentration of oxidants generated in 1 and 2 component electrodes was in the order of: $ClO_2$> free Cl>$H_2O_2>O_3$. OH radical was not generated from in entire one and two component electrodes. RhB degradation rate and generated oxidants of the Ru-Sn=9:1 electrode was higher than that of the two component electrode. The exact relationship between the removal of RhB and the generated oxidants concentration was not obvious. However, it was assumed that electrode with high RhB decolorization had high oxidant concentration.