• Title/Summary/Keyword: angular deformity

Search Result 41, Processing Time 0.023 seconds

Comparison of Angle Measurements on Hallux Valgus with Two Different Methods Using Digital Images (디지털 영상을 이용한 무지 외반증 변형각 측정에서 서로 다른 두 계측 방법의 비교)

  • Sung, Il-Hoon;Kim, Ki Chun;Sung, Chang-Ho;Seo, Woo-Young;Lee, Doo-Yeon;Cho, Young A
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • Purpose: To study inter- and intra-observer reliabilities of computerized measurements of the angular parameters of hallux valgus deformity, using two different kinds of software tools for angle measurement on the digital radiography. Materials and Methods: On 35 digital radiographies of standing foot anteroposterior view of hallux valgus, two observers (A, B) independently measured hallux valgus angle (HVA) and 1-2 intermetatarsal angle ($IMA_{1-2}$) twice, using two methods. In method I, an angle was determined from duplicated lines to longitudinal axes made for bisecting line on the target bones with software tool. In method II, an angle was calculated automatically and directly from bisecting lines (longitudinal axes) made on the target bones. We compared two methods using paired t-test to determine significance of differences. Inter- and intraobserver reliabilities were evaluated using the intraclass correlation coefficients (ICC). Results: There were no significant differences between measurements of method I and II for each observer (p>0.05) and intraobserver reliability were good. (ICC>0.9) Inter-observer reliability for method I and II was good of the HVA (ICCs, 0.912 and 0.905) and moderate of the $IMA_{1-2}$ (ICCs, 0.505 and 0.537). There were interobserver differences in HVA of method I and II. Conclusion: No significant difference was found statistically between measurements of method I and II. Both methods I and II would be acceptable to measure angular parameters of hallux valgus deformity.

Radiological Analysis of the Degenerative Arthritis of the Ankle (족관절 퇴행성 관절염의 방사선학적 분석)

  • Lee, Woo-Chun;Kang, Yeong-Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.2
    • /
    • pp.135-139
    • /
    • 2005
  • Purpose: This study was performed to investigate the radiological characteristics of the degenerative arthritis of the ankle using the standing radiographs. Materials and Methods: From June 2001 to May 2005, 36 patients (56 ankles) who were treated for osteoarthritis of ankle were analysed. Angle of tibial shaft and tibial joint surface on AP view (TSA), angle of tibial joint surface on lateral view (TLS), tibial and medial malleolus angle (TMM) and talo-1st metatarsal angle were checked on standing radiograph. The patients with medial joint and total joint involvement were categorized into three stages according to the location of involvement. The degree of joint space narrowing was categorized into two groups. Results: There were no significant differences in TSA, TLS, TMM and talo-1st metatarsal angle with regard to the stage of arthritis. However, the difference between the less severe group and the severe group existed. Conclusion: Angular deformity was not correlated with stage, but correlated with severity. The deformity of distal tibial articular surface does not seem to be a cause of primary osteoartiritis, but rather a result from it.

  • PDF

Application of External Skeletal Fixations to Correct the Growth Deformities in a Dog (개에서 외골격 고정을 이용한 성장 기형의 교정)

  • 김영삼;변예은;윤성진;오태훈;박옥지;임지혜;최민철;권오경
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.410-412
    • /
    • 2003
  • A male, 11-month-old, Shih-tzu dog weighing 5.2kg showing knuckling secondary to severe cranial bowing of left antebrachium with valgus deformity of the carpus was presented to the Veterinary Medicine Teaching Hospital of Seoul National University. Radiographic findings were a premature closure of the distal ulnar physis, a cranial bowing of the radius, subluxation of the elbow joint, and degenerative changes in the carpal joint. The patient was treated by performing an oblique osteotomy of the radius and ulna, followed by application of External Skeletal Fixations. At 18 weeks postoperatively, the radius was healed. An incongruency of the elbow joint and radial angular deformity was corrected.

Effects of Osteotomy Angle on Tibial Angulation and Torsion During CORA-Based Leveling Osteotomy in Toy Breed Dogs: A Computer Modeling-Based Study

  • Jeong, Youngeun;Jeong, Jaemin;Cho, Cheongwoon;Jeong, SeongMok;Lee, Hae Beom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.175-179
    • /
    • 2020
  • The objective of this study was to determine the effect of osteotomy angle and tibial proximal segment rotation angle on angular and torsional tibial deformities and to assess the trends of these deformities during the rotation of the tibial proximal segment in a center of rotation of angulation (CORA)-based leveling osteotomy (CBLO) by performing computer modeling of the tibia. Four tibias of toy breed dogs with no history of lameness were used in this study. Osteotomies were performed in the proximal tibias at angles of 0°, 10°, 20°, -10°, and -20°, perpendicular to either the proximodistal or craniocaudal tibial axes. The mechanical medial proximal tibial angle (mMPTA) and transcondylar (TC) and distal cranial tibial (CnT) axes were used to measure angular and torsional deformities, respectively. All tibias showed an increase in angular and rotational deformities with an increase in the tibial plateau rotation angle. The tibia with osteotomies performed in the proximodistal and craniocaudal directions showed the highest magnitude of torsional and angular deformities, respectively. The results of this study revealed a tendency of occurrence of angular and torsional deformities with osteotomy performed along the proximodistal and craniocaudal directions in the CBLO.

A PHOTOMETRIC STUDY OF THE FACIAL PROFILES OF KOREAN ADULT WOMAN (한국 성인 여성의 안모에 대한 실물 사진 계측학적 연구)

  • Park, Moo-Chull;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.1_2
    • /
    • pp.54-64
    • /
    • 1992
  • The balance of facial sop tissue is important factor for the treatment of maxillofacial deformity patients. There are many cephalometric analysis of facial bone but a few soft tissue analysis of face for the orthognathic surgery, especially in the oriental people. This study aimed at examining the mean value of the soft tissue measurement of 120 Korean adult women with the linear and angular measurement and comparing with Caucasian. The results ere as follows. 1. In the frontal linear measurement, Korean women have larger interocular distant and width of nose, but the width of mouth appeared less than Caucasian. 2. In the frontal angular measurement, Korean women have larger inclination of the eye than Caucasian. 3. In the lateral linear measurement, Korean women have more prominent upper and lower lip position than Caucasian and have longer upper facial height comparing with lower facial height than Caucasian. 4. In the lateral angular measurement, Korean women have more convex facial profile and less nasolabial and geniolabial angle. 5. In the lateral facial ratio, Korean women have larger proportion in the lower department below the stomion.

  • PDF

Determination of Femoral and Tibial Joint Reference Angles in Small-breed Dogs

  • Kim, Jooho;Heo, Suyoung;Na, Jiyoung;Kim, Namsoo;Kim, Minsu;Jeong, Seongmok;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.340-345
    • /
    • 2016
  • The present study determined the normal reference ranges for the femoral and tibial joint orientation angles of small-breed dogs. For this purpose, 60 each of cadaveric canine femurs and tibias from normal small-breed dogs (Maltese, Poodle, Shih Tzu, Yorkshire Terrier) were examined with radiographs and photographs. Axial and frontal radiographs and photographs of each bone were obtained, from which anteversion and inclination angles, anatomic lateral proximal and distal femoral angles (aLPFA and aLDFA), mechanical lateral proximal and distal femoral angles (mLPFA and mLDFA), and mechanical medial proximal and distal tibial angles (mMPTA and mMDTA) were measured. The 95% CI for radiographic values of all femurs and tibiae were anteversion angle, $23.4-27.4^{\circ}$; inclination angle, $128.4-130.4^{\circ}$; aLPFA, $117.8-122.1^{\circ}$; aLDFA, $93.7-95.2^{\circ}$; mLPFA $113.8-117.3^{\circ}$; mLDFA $99.2-100.5^{\circ}$; mMPTA $96.8-98.5^{\circ}$; mMDTA $89.4-90.7^{\circ}$. The Maltese had a larger anteversion angle than the Poodle and the Yorkshire Terrier and a larger mLPFA than the Poodle. In the comparison between the radiographs and the photographs, significant differences were found in the anteversion angle, mLPFA, mMPTA, and mMDTA. The established normal reference values might be useful for determining whether a valgus or varus deformity of the femur or the tibia is present and if so, the degree of angular correction needed.

Comparison of Clinical and Radiologic Results between Expandable Cages and Titanium Mesh Cages for Thoracolumbar Burst Fracture

  • Lee, Gwang-Jun;Lee, Jung-Kil;Hur, Hyuk;Jang, Jae-Won;Kim, Tae-Sun;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.142-147
    • /
    • 2014
  • Objective : A thoracolumbar burst fracture is usually unstable and can cause neurological deficits and angular deformity. Patients with unstable thoracolumbar burst fracture usually need surgery for decompression of the spinal canal, correction of the angular deformity, and stabilization of the spinal column. We compared two struts, titanium mesh cages (TMCs) and expandable cages. Methods : 33 patients, who underwent anterior thoracolumbar reconstruction using either TMCs (n=16) or expandable cages (n=17) between June 2000 and September 2011 were included in this study. Clinical outcome was measured by visual analogue scale (VAS), American Spinal Injury Association (ASIA) scale and Low Back Outcome Score (LBOS) for functional neurological evaluation. The Cobb angle, body height of the fractured vertebra, the operation time and amount of intra-operative bleeding were measured in both groups. Results : In the expandable cage group, operation time and amount of intraoperative blood loss were lower than that in the TMC group. The mean VAS scores and LBOS in both groups were improved, but no significant difference. Cobb angle was corrected higher than that in expandable cage group from postoperative to the last follow-up. The change in Cobb angles between preoperative, postoperative, and the last follow-up did not show any significant difference. There was no difference in the subsidence of anterior body height between both groups. Conclusion : There was no significant difference in the change in Cobb angles with an inter-group comparison, the expandable cage group showed better results in loss of kyphosis correction, operation time, and amount of intraoperative blood loss.

Computerized Measurement on Angular Parameters for Hallux Valgus: Comparison of 100% and 150% Magnified Digital Radiography (무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교)

  • Sung, Il-Hoon;Lee, Doo-Yeon;Sung, Chang-Ho;Seo, Woo-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • Purpose: To study computerized measurements of angular parameters on 100% and 150% resized digital radiography of hallux valgus deformity Materials and Methods: 30 digital radiography of standing foot anteroposterior view of hallux valgus patients were included. Two observers(A, B) independently measured hallux valgus angle (HVA), 1-2 intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) in two times on both 100%-size and 150% magnified images respectively, using computerized measurement software tools. The results were interpreted with the statistical software program, Statistical Analysis System, version 9.2. Results: In repeated measurements of each observer, measurements on 150% magnified image showed no differences of all three parameters and with 100%-size image, there were differences of HVA (observer A) and 1-2 IMA (observer B) (p>0.05). When testing interobserver reliability, both observers showed differences in measurement of HVA and DMAA (p<0.05), but no differences in measurement of 1-2 IMA in both images. Within the 95% confidence interval, limits of error of measurements between two observers on HVA, IMA and DMAA were $2.7^{\circ}$ $1.4^{\circ}$ and $5.0^{\circ}$ respectively in 100%-size images, and $2.6^{\circ}$, $1.6^{\circ}$ and $4.7^{\circ}$ respectively in 150% magnified images. Conclusion: In computerized measurements for angular parameters of hallux valgus with digital radiography, 150% magnified images showed intraobserver reliability. Both 100% and 150% magnified images failed to show interobserver reliability. Measurement of 1-2 IMA in both 100% and 150% images showed less interobserver error.

Analysis of Facial Asymmetry in Deformational Plagiocephaly Using Three-Dimensional Computed Tomographic Review

  • Moon, Il Yung;Lim, So Young;Oh, Kap Sung
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.3
    • /
    • pp.109-116
    • /
    • 2014
  • Background: Infants with deformational plagiocephaly (DP) usually present with cranial vault deformities as well as facial asymmetry. The purpose of this study was to use three-dimensional anthropometric data to evaluate the influence of cranial deformities on facial asymmetry. Methods: We analyzed three-dimensional computed tomography data for infants with DP (n=48) and without DP (n=30, control). Using 16 landmarks and 3 reference planes, 22 distance parameters and 2 angular parameters were compared. This cephalometric assessment focused on asymmetry of the orbits, nose, ears, maxilla, and mandible. We then assessed the correlation between 23 of the measurements and cranial vault asymmetry (CVA) for statistical significance using relative differences and correlation analysis. Results: With the exception of few orbital asymmetry variables, most measurements indicated that the facial asymmetry was greater in infants with DP. Mandibular and nasal asymmetry was correlated highly with severity of CVA. Shortening of the ipsilateral mandibular body was particularly significant. There was no significant deformity in the maxilla or ear. Conclusion: This study demonstrated that the cranial vault deformity in DP is associated with facial asymmetry. Compared with the control group, the infants with DP were found to have prominent asymmetry of the nose and mandible.

Total Deformity Angular Ratio as a Risk Factor for Complications after Posterior Vertebral Column Resection Surgery

  • Lee, Byoung Hun;Hyun, Seung-Jae;Han, Sanghyun;Jeon, Se-Il;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.723-730
    • /
    • 2018
  • Objective : The aim of the present study was to identify whether the deformity angular ratio (DAR) influences the occurrence of complications after posterior vertebral column resection (PVCR) and to establish the DAR cut-off value. Methods : Thirty-six consecutive patients undergoing PVCR from December 2010 to October 2016 were reviewed. The relationships between the total, sagittal, and coronal DAR and complications were assessed using receiver operator characteristics curves. The patients were divided into two groups according to a reference value based on the cut-off value of DAR. Demographic, surgical, radiological, and clinical outcomes were compared between the groups. Results : There were no significant differences in the patient demographic and surgical data between the groups. The cut-off values for the total DAR (T-DAR) and the sagittal DAR (S-DAR) were 20.2 and 16.4, respectively (p=0.018 and 0.010). Both values were significantly associated with complications (p=0.016 and 0.005). In the higher T-DAR group, total complications (12 vs. 21, p=0.042) and late-onset complications (3 vs. 9, p=0.036) were significantly correlated with the T-DAR. The number of patients experiencing complications (9 vs. 11, p=0.029) and the total number of complications (13 vs. 20, p=0.015) were significantly correlated with the S-DAR. Worsening intraoperative neurophysiologic monitoring was more frequent in the higher T-DAR group (2 vs. 4) than in the higher S-DAR group (3 vs. 3). There was no difference in neurological deterioration between the groups after surgery. Conclusion : Both the T-DAR and the S-DAR are risk factors for complications after PVCR. Those who had a T-DAR >20.2 or S-DAR >16.4 experienced a higher rate of complications after PVCR.