• 제목/요약/키워드: angle-only measurement

Search Result 198, Processing Time 0.029 seconds

Tilt Angle Measurement Based on Arrayed Eddy Current Sensors

  • Chao, Xuewei;Li, Yang;Nie, Jing
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.524-528
    • /
    • 2016
  • Eddy current (EC) sensor works based on the electromagnetic induction principle and has been widely applied in the industrial testing and evaluation due to its robustness and environmental adaptability. Meanwhile, tilt angle measurement is mainly based on the laser or visual method, which is strict with the measurement environment and not suitable for the industrial applications. In this paper, a novel tilt angle measurement method based on arrayed EC sensors is proposed. Both the simulation and experiments indicate that the measured error is approximately linear with tilt angle and the accuracy after compensation is $0.25^{\circ}$. In conclusion, this research cannot only broaden the scope of EC application, but also overcome the shortcomings of existing angle measurement methods.

TECHNIQUE OF SEPARATE MEASURING SIDE SLIP FOR TOE ANGLE AND CAMBER ANGLE

  • Nozaki, H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.6
    • /
    • pp.681-686
    • /
    • 2006
  • The current flat type side slip tester measures only the total side slip. Therefore, measurement techniques which can be used to determine the side slip for each alignment element were examined. Because the side slip related to the camber angle varies depending on the unit load per travel wheel while the side slip related to the toe angle does not on the unit per travel wheel, but depends only on the direction of the tire, the side slip for each alignment element can be determined separately.

Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor (토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가)

  • Jung, Chang Jin;Jo, Jung Hee;Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

Design of Linear Interferometer Antenna Regarding Beamwidth (빔폭을 고려한 선형간섭계 안테나 설계)

  • Choi, Ik-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.693-700
    • /
    • 2016
  • In this paper, it is represented that equations for design of linear interferometer antenna when the 3 dB beamwidth is only region of interest. Using the equations, relationships between angle measurement ambiguity and element antenna spacings are described. And then, operating frequency, angle measurement accuracy, beamwidth, correct measurement probability are calculated for five antennas interferometer to measure azimuth and elevation angle. The interferometer antenna was designed and fabricated using the calculated parameters. The angle measurement accuracy were $0.01^{\circ}$ and $0.016^{\circ}$ for azimuth and elevation axes with 99 % probability of doing measurements correctly which means that ambiguous solution did not occur more than 1 % of the time. These results validated the equations and design procedures.

Rapid Prototyping of Head-of-Bed Angle Measurement System using Open-Source Hardware (오픈소스하드웨어를 이용한 침상머리각도 측정 시스템의 래피드 프로토타이핑)

  • Jo, Bong-Un;Park, Yeong-Sang;Seo, Sugkil;Kim, Jin-Geol;Lee, Young-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1038-1043
    • /
    • 2015
  • When the study on the relationship between the Head-of-Bed (HOB) angle and ventilator-associated pneumonia is performed, the fact that the HOB angle can only be measured intermittently imposes a significant limitation on the study. Therefore, there has been demand for the development of a device that can measure the HOB angle continuously. In this paper, we propose the rapid prototyping of an HOB measurement system using open-source hardware and software. The proposed system helps to maintain the HOB angle at a particular angle by displaying the angle and helps the medical study of pneumonia patients by enabling continuous data acquisition. Firstly, we eliminate the process of making an MCU board by utilizing an open-source hardware mbed LPC1768. Secondly, we reduce the software development time by using libraries and hence enabling the easy use of peripherals. Thirdly, for rapid prototyping, we build the enclosure of the proposed system using a 3D printer. The proposed system can be attached and detached to and from a bed. Therefore, we can attach it to the bed of a patient for whom measurement of the HOB angle is necessary. Finally, we check the measurement performance and the validity of the proposed system through an experiment utilizing an incremental encoder.

Two-Site Optical Observation and Initial Orbit Determination for Geostationary Earth Orbit Satellites

  • Choi, Jin;Choi, Young-Jun;Yim, Hong-Suh;Jo, Jung-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.337-343
    • /
    • 2010
  • Optical observation system provides angle-only measurement for orbit determination of space object. Range measurement can be directly acquired using laser ranging or tone ranging system. Initial orbit determination (IOD) by using angle- only data set shows discrepancy according to the measurement time interval. To solve this problem, range measurement data should be added for IOD. In this study, two-site optical observation was used to derive the range information. We have observed nine geostationary earth orbit satellites by using two-site optical observation system. The determination result of the range shows the accuracy over 99.5% compared to the results from the satellite tool kit simulation. And we confirmed that the orbit determination by the Herrick-Gibbs method with the range information obtained from the two-site observation is more accurate than the orbit determination by Gauss method with the one-site observation. For more accurate two-site optical observation, a baseline should satisfy an optimal condition of length and more precise observation system needed.

Performance Analysis of Adaptive Extended Kalman Filter in Tracking Radar (추적 레이더에서 적응형 확장 칼만 필터의 성능 분석)

  • Song, Seungeon;Shin, Han-Seop;Kim, Dae-Oh;Ko, Seokjun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.223-229
    • /
    • 2017
  • An angle error is a factor obstructing to track accurate position in tracking radars. And the noise incurring the angle error can be divided as follows; thermal noise and glint. In general, Extended Kalman filter used in tracking radars is designed with considering thermal noise only. The Extended Klaman filter uses a fixed measurement error covariance when updating an estimate state by using ahead state and measurement. But, a noise power varies according to the range. Therefore we purposes the adaptive Kalman filter which changes the measurement noise covariance according to the range. In this paper, we compare the performance of the Extended Kalman filter and the proposed adaptive Kalman filter by considering KSLV-I (Korean Satellite Launch Vehicles).

Defects Length Measurement using an Estimation Algorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup;Kang, E-Sok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1452-1457
    • /
    • 2004
  • In this paper, a method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed to an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle to the image normal to the wall and thus, it enables the accurate measurement of the defect lengths only by using a single camera and a laser slit beam.

  • PDF

Indoor Positioning System using Incident Angle Detection of Infrared sensor (적외선 센서의 입사각을 이용한 실내 위치인식 시스템)

  • Kim, Su-Yong;Choi, Ju-Yong;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.991-996
    • /
    • 2010
  • In this paper, a new indoor positioning system based on incident angle measurement of infrared sensor has been suggested. Though there have been various researches on indoor positioning systems using vision sensor or ultrasonic sensor, they have not only advantages, but also disadvantages. In a new positioning system, there are three infrared emitters on fixed known positions. An incident angle sensor measures the angle differences between each two emitters. Mathematical problems to determine the position with angle differences and position information of emitters has been solved. Simulations and experiments have been implemented to show the performance of this new positioning system. The results of simulation were good. Since there existed problems of noise and signal conditioning, the experimented has been implemented in limited area. But the results were acceptable. This new positioning method can be applied to any indoor systems that need absolute position information.

Two Unresolved Target Angle Estimation in Phase Comparison Monopulse Radar (위상비교모노펄스를 이용한 근접한 두 표적 분리에 관한 연구)

  • Lee, Seung-Phil;Cho, Byung-Lae;Kim, Young-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.539-544
    • /
    • 2016
  • This paper improves Sherman's two-pulse method for angle estimation of two unresolved targets in phase comparison monopulse radar. The proposed method provides the angle information with only a single-pulse measurement instead of two pulses. The proposed method can estimate a single-target angle by single-target indicator, in contrast with previous techniques. The accuracy of angle estimation for proposed method is demonstrated by simulations.