• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.023 seconds

A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant (시흥정수장 막여과시설 시범운영)

  • 김한승;김충환;김학철;윤재경;안효원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

Assessment of Bacteria Removal Using Silver Ion Absorbed Ceramic Filter

  • Kim, Woo-Hang;Smith, James
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.901-907
    • /
    • 2012
  • The objective of this study was to evaluate bacteria removal ability of the metallic silver which was baked silver ion impregnated ceramic filter at heating condition. Silver leaking from baked ceramic filter was tested to sustain bacteria removal for a long time. Silver impregnated ceramic filter could remove E. coli completely at $10^{12}$ MPN/100ml to $10^{13}$ MPN/100ml of influent. However, ceramic filter without silver did not remove E. coli completely under the same condition. After baking, the silver impregnated ceramic filter almost didn't leak out the silver ion from filter. Photo of TEM (Transmission Electron Microscopy) showed that absorbed silver ions remained in ceramic filter after baking process and most of silver were less than 10 nm. According to the increase in the amount of silver in the ceramic filter, removal efficiencies of E. coli were increased but turbidity removal was decreased. It can be accounted that increased removal efficiency of E. coli was from disinfection of silver that is in the ceramic filter. Simulated concentrations of bacteria agree well with the observed experimental effluent concentration data. Moreover, first-order decay coefficients increased to 0.0034/min after silver was added in the ceramic filter. Increase of first-order decay coefficient proves that silver-added ceramic filter can remove bacteria easily.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (II) - Assessment of the FDA System through a Site Application - (시설용수 및 영농편의용수 공급시스템 개발 (II) - FDA 시스템 현장적용성 평가 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.101-106
    • /
    • 2009
  • The previous study developed the Filter-Disinfection-Adsorption (FDA) system to provide clean irrigation water for greenhouse cultivation as well as convenience water to farmers. In this study, the field examination was undertaken to assess performance of the FDA system. The field application was made in the suburb of Daegu, one of the large city in Korea. The study area located near by down-stream of Gum-Ho river is suffering low irrigation water quality problems with no water supply service facilities. Four water quality parameters including Suspended Solid (SS), Biological Oxygen Demand (BOD), coliform, and turbidity were selected to test the purification performance of FDA system. Also in order to improve the system, this study investigated the defects of using the FDA system through field monitoring. As results, it was found that this system can be used to supply good quality of irrigation water for greenhouse cultivation and also provide convenience water to farmers in the field areas of no water supply services.

Bidirectional Spreading of Gravity Underflows on an Incline (사면에 발달하는 하층밀도류의 이차원흐름)

  • Choe, Seong-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.1
    • /
    • pp.83-94
    • /
    • 1999
  • In continental margins, turbid underflows which are not confined to a given channel, are free to spread laterally as well as longitudinally. Lateral spreading can reduce substantially the run out distance of flows along continental shelves and slopes. Laboratory experiments with a large tank, employing saline density currents as surrogates for fine-grained turbidity flow, coupled with dimensional analysis, have been used to develop a simple expression for lateral spreading rates of two-dimensional flows on sloping beds. characteristic length and time are determined by the flow discharge and buoyancy flux at the inlet. By knowing the initial width of the flow, the spreading law can be used to estimate the maximum width of the current at different times as well as the longitudinal spreading rate. Predictions for flows compare favorably against observations.

  • PDF

A DISCUSSION ON THE MAIN REASONS CAUSING THE MASS MORTALITY OF CORALS AND BENTHOS IN CONDAO ISLAND DURING OCTOBER 2005.

  • Son, Tong Phuoc Hoang;Khin, Lau Va;Ben, Hoang Xuan;Knee, Tan Chun;Ishizaka, Joji;Ransibrahmanakul, Varis;Tripathy, Sarat Chandra
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.463-466
    • /
    • 2006
  • During Mid October of 2005 a mass mortality of the corals occurred surrounding Con Dao Islands (South Vietnam) where is the recognized as one of the most famous marine parks of Vietnam. Results from the field survey in October 2005 showed that the mass mortality of corals and benthos focused only on the North-West of the islands whereas there was almost no death recorded in the South - East parts. Based on field data it was assumed that an overlap between high water temperature ($>30^{\circ}C$) and low salinity (<25%o) during short term was the impact causing the situation. In this paper, we try to explain this phenomenon based on the hydrographical view together with analyzing ocean colour images. A coral bleaching warning system also is proposed for Condao site.

  • PDF

Three-Dimensional Numerical Simulation of Intrusive Density Currents

  • An, Sangdo
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1223-1232
    • /
    • 2014
  • Density currents have been easily observed in environmental flows, for instance turbidity currents and pollutant plumes in the oceans and rivers. In this study, we explored the propagation dynamics of density currents using the FLOW-3D computational fluid dynamics code. The renormalization group (RNG) $k-{\varepsilon}$ scheme, a turbulence numerical technique, is employed in a Reynold-averaged Navier-Stokes framework (RANS). The numerical simulations focused on two different types of intrusive density flows: (1) propagating into a two-layer ambient fluid; (2) propagating into a linearly stratified fluid. In the study of intrusive density flows into a two-layer ambient fluid, intrusive speeds were compared with laboratory experiments and analytical solutions. The numerical model shows good quantitative agreement for predicting propagation speed of the density currents. We also numerically reproduced the effect of the ratio of current depth to the overall depth of fluid. The numerical model provided excellent agreement with the analytical values. It was also clearly demonstrated that RNG $k-{\varepsilon}$ scheme within RANS framework is able to accurately simulate the dynamics of density currents. Simulations intruding into a continuously stratified fluid with the various buoyancy frequencies are carried out. These simulations demonstrate that three different propagation patterns can be developed according to the value of $h_n/H$ : (1) underflows developed with $h_n/H=0$ ; (2) overflows developed when $h_n/H=1$ ; (3) intrusive interflow occurred with the condition of 0 < $h_n/H$ < 1.

Effect of Varous Physicochemical Factors on the Biodegradation of Explosive 2,4,6-Trinitrotoluene by Stenotropomonas maltophilia (Stenotrophomonas maltophilia에 의한 폭약 2,4,6-Trinitrotoluene의 생분해에 영향을 미치는 물리화학적 요인)

  • 김영진;이명석;조윤석;한현각;김승기;오계헌
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.315-321
    • /
    • 1999
  • The relationships between the explosive 2,4,6-trinitrotoluene (TNT) degradation by Stenotrophomonas maltophilia and several relevant physicochemical environmental parameters were examined. At neutral pH of the cultures, the degradation of TNT proceeded to completion, whereas only about 50% of TNT was utilized when the cultures were adjusted to acidic pH. The effect of various co-substrates (e.g., glucose, fructose, acetate, citrate, succinate) on the degradation of TNT by the test culture of S. maltophilia was evaluated. The results indicated that, among the various co-substrates studies, the test culture that received 2 mM fructose degraded 100 mg/L of TNT completely within 20 days of incubation at ambient temperature, whereas partial degradation of TNT was observed in the test culture with acetate, citrate, or succinate as a co-substrate, respectively. In fact, fructose was the best co-substrate for TNT degradation in this experiment. The effect of supplemented nitrogens [e.g., (NH$_4$)$_2$,SO$_4$, NH$_4$Cl. urea] on the TNT degradation was monitored. All supplemented nitrogens in this study were inhibitory to TNT degradation. Addition of 1% Tween80 accelerated TNT degradation, and showed complete degradation of TNT within 8 days of incubation. Addition of yeast extract resulted higher growth yields, based on turbidity measurement, but it inhibited TNT degradation.

  • PDF

Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam (전자선을 이용한 하수처리장 방류수내 대장균군 살균)

  • Kim, Yuri;Han, Bumsoo;Kim, Jinkyu;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

A Study on the Performance Improvement of Flash-Mixer in Water-Treatment Plant (정수장 급속혼화설비 성능향상에 관한 연구)

  • Cho, In-Jun;Oh, Sang Han;Lee, Sang Wook;Son, Chang Ho;Chung, Wui Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 2011
  • In results of accomplishing fundamental study to improve the flocculant-mixing of the Flash-Mixer in Onsan Water-Treatment Plant at the small cost, We obtained 8.9% of mixing-efficiency from the field data and 3.2% of the characteristic flow-ratio as the available maximum volume-ratio in this Water-Treatment Plant. The optimum elements with the deflector diameter of 400 mm and deflector angle of $145^{\circ}$ at the flow ratio of 3.2% could be obtained from the expanded study on the ground of the fundamental study. Finally, the efficiency could be improved about 510% from 8.9% to 45.4% and the average turbidity could be improved about 14%.

The Effect of Pre-chlorination on the Coagulation of Microcystis aeruginosa (전염소처리가 Microcystis aeruginosa 응집에 미치는 영향)

  • Lee, Tae-Gwan;Jin, Jung-Sook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.505-510
    • /
    • 2000
  • In this study the effects of pre-chlorination on the coagulation of water which contain Microcystis aeruginosa. were investigated on the laboratory scale. We prepared the sample of $10^5cell/mL$ Microcystis aeruginosa and then applied 0.2, 1.0, 10 mg-Cl/L chlorine on the sample After reaction period(1 minute and 1 hour), each sample was coagulated. As a result, after 0.4 mg-Al/L coagulant dose, turbidities of all samples were below 2 mg-Kaolin/L. Turbidity was not affected by chlorine dose. As the dose of chlorine was increased, the residual aluminum was decreased, but result of $UV_{254}$ was adverse.

  • PDF