• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.035 seconds

Determination of Sizes of Nano-Particles by Specific Turbidimetry (비혼탁도 법을 이용한 나노 콜로이드 입자의 크기 결정)

  • Lim, Kyung-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.107-114
    • /
    • 2008
  • In this article a reliable and rapid method based on specific turbidimetry is proposed for the determination of sizes of nanoparticles. Conventionally in specific turbidimetry specific turbidities for a colloidal dispersion are measured as a function of light wavelength, and compared to theoretical values calculated from Mie scattering theory for presumed particle sizes. In contrast specific turbidity at a fixed wavelength is measured in the proposed method, and particle sizes are determined from the prepared calibration curve. The calibration curve is a plot of specific turbidity vs particle size and in this case the specific turbidities are measured for a couple of samples of known sizes.

Study of Installation of Sediment Trap Drain Channel to Reduce Soil Erosion from Storm Water Runoff (침사기능 콘크리트 배수로의 유사 유출 저감에 관한 연구)

  • Shin, Hyun-Jun;Won, Chul-Hee;Choi, Yong-Hun;Kim, Tae-Yoo;Choi, Jung-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.95-100
    • /
    • 2010
  • Researchers developed Sediment Trap Drain Channel (STDC) as a solution of the reduction of soil erosion and muddy runoff from a alpine field. The STDC is the one that can take a role of grit chamber by installing the shield made of woods in the concrete channel. The study was conducted 8 kinds of stages according to the amount of soil loss and the inflow. Evaluation factors were ss concentration, turbidity and reduced soil. The results of study showed lessness of ss concentration and turbidity from the lower spot than the upper spot. The average reduction rate of ss concentration was 74 % and the average reduction rate of turbidity was 62 %. It was turned out that the performance related soil loss and muddy runoff of the STDC is effective. The governance was needed to expect the effectiveness of the STDC.

Turbidimetric Measurement for On-line Monitoring of SiO2 Particles

  • Kim, In-Sook;Kim, Yang-Sun;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.801-805
    • /
    • 2004
  • In this work, the fundamental study of on-line monitoring of $SiO_2$ particles in the size range of 40 nm to 725 nm was carried out using turbidimetry. The size of particle was measured using a field emission scanning electron microscope (FE-SEM). The factors affecting on the turbidity were discussed, for example, wavelength, size, and concentration. In order to observe the dependence of turbidity on the wavelength, a turbidimetric system equipped with charged coupled detector (CCD) was built. The shape of the transmitted peak was changed and the peak maximum was shifted to the red when the concentration of particle was increased. This result indicates that the turbidity is related to the wavelength, which corresponds to the characteristic of the Mie extinction coefficient, Q, that is a function of not only particle diameter and refractive index but also wavelength. It is clear that a linear calibration curve for each particle in different size can be obtained at an optimized wavelength.

Coagulation Properties of Granite Particle (화강석 잔사의 응집특성)

  • 홍영호
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2002
  • This study was carried out to investigate the optimal condition for granite particle coagulation process by using various chemical coagulation agents. The coagulation of a suspended granite particle was monitored by using various different coagulants, such as $Al_2(SO_4)_3{\cdot}14H_2O,{\;}FeCl_3{\cdot}6H_2O,{\;}SA-solution(KOH{\;}+{\;}Al(OH)_3{\;}+{\;}K_2CO_3{\;}mixture)$ and jade particle. To accomplish this study, analysis of water quality, removing Turbidity and Packing Density were measured with jar-tester. In the results of this experiment, it was found that the removal rate of the granite particle was increased with the decrease of the pH of the sludge. The turbidity(NTU) at the above coagulants was reduced from 95% to 98%. Removed of Turbidity and Packing Density was more efficiency to the SA-solution than others.

A Study on Turbidity Calibration of Borehole Roughness Measurement System (BKS-LRPS) (굴착공 벽면거칠기 측정시스템(BKS-LRPS)의 혼탁도 보정에 관한 연구)

  • Park, Bong-Geun;Choi, Yong-Kyu;Kim, Myung-Hak;Kwon, Oh-Kyun;Nam, Moon-S.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1-10
    • /
    • 2009
  • Based on recent studies, the side resistance of rock socketed drilled shafts was affected by unconfined compressive strength of rock, socket roughness, rock types and joints, and initial normal stress. Especially, the socket roughness was affected by rock types and joints, drilling methods, and diameters of pile. In this study, a new roughness measurement system (BKS-LRPS, Backyoung-KyungSung Laser Roughness Profiling System) usable in water was developed. Based on the laboratory model tests, an EMD (Effective Measurement Distances) according to various turbidity was proposed as EMD=$1149.2{\times}T^{-0.64}_b$.

  • PDF

TiO2 Removal using Electrocoagulation-electroflotation Two-step Process (전기응집-전기부상 2단계 공정을 이용한 TiO2 제거)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.385-394
    • /
    • 2023
  • There is a need for a method that can effectively remove wastewater containing small-sized particles such as TiO2. In this study, we attempted to remove TiO2 wastewater using electrocoagulation-electroflotation two-step separation. The TiO2 wastewater was effectively removed via batch electrocoagulation-electroflotation separation. However, in the batch process, the simultaneous operation of electrocoagulation and electoflotation was challenging due to the high residual turbidity. In the continuous operation, electrocoagulation and electoflotation reactors were kept separate. The turbidity removal in continuous operation was similar to that in the batch process, nevertheless, the residual Al concentration was high, leading to the conclusion that counterterm ensures against residual Al were necessary.

Outflow Characteristics of Floating Material by Rainfall Intensity in the Upper Stream of Soyang River (소양호(昭陽湖) 상류유역(上流流域)의 강우강도(降雨强度)에 따른 부유물질유출특성(浮游物質流出特性))

  • Choi, Han-kuy;Yoo, Sang-Mo;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.11-18
    • /
    • 2005
  • When it is raining or snowing, floating debris flows into a lake and raises its turbidity. High level of turbidity in the lake often causes eutrophication, which pollutes the water. In order to collect and present some essential information for effective management plan for water quality, we carried out our research at the watershed of Mandae-cheon located at the upstream of Soyang Lake. We examined water quality at the time of rainfall or snowfall to analyze the changes in the amount of suspend soils(SS) in the lake.

  • PDF

Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.761-772
    • /
    • 1998
  • This study was performed to determine the optimum coagulant dosing amount for effective treatment of raw water. The removal rate of turbidity and the variations of water qualities according to various dosage of coagulants such as Alum, PAC and PACS were investigated. The optimum coagulant dosing amount to make the lowest turbidity of water were 35mg/ι t of Alum, 30mg/ι of PAC and 10mg/ι of PACS in case of 5 NTU of raw water turbidity, and 30mg/ι of Alum, 25mg/ι of PAC and 10mg/ι of PACS in case of 10 NTU of that, respectively. The removal rates of turbidity at 4 min. and 8 min. of settling time were 10 and 72% of Alum, 44 and 62% of PAC and 25 and 55% of PACS in case of 5 NTU, and 52 and 70% of Alum, 90 and 95% of PAC and 10 and 28% of PACS in case of 10 NTU, respectively. Judging from the settling capability of floc., the reaction time of floe. formation and removal efficiency of turbidity, PAC was evaluated as more effective coagulant than Alum and PACS. Also PAC was regarded as the most effective coagulant when the water supply was changed sharply and the fluctuation of the surface loading occured with wide and sharp in settling basin. pH and alkalinity of the water were decreased with increasing coagulants dosage. But pH and alkalinity were not decreased below 5.8 which is the standard for drinking water quality, and 10mg/ι which is the limit concentration of floc. breakage, respectively. Residual Al of the treated water was decreased with increasing coagulants dosage in case of 5 and 10NTU of raw water turbidity. $KMnO_4$ consumption of the water was decreased with increasing coagulants dosage. The reduction rate of $KMnO_4$ consumption at the optimum coagulants dosage were 39% of Alum. 18% of PAC and 11% of PACS in case of 5 NTU of raw water turbidity, and 42% of Alum, 27% of PAC and 36% of PACS in case of 10 NTU of that, respectively. Any relationship was not found between the removal rate of turbidity and KMnO$_4$ consumption. TOC of the water was a bit decreased with increasing coagulants dosage up to 30mg/ι but not changed above 30mg/ι of coagulants dosage. The degree of TOC reduction was increased in the order of Alum, PAC and PACS treatment. Zeta potential of the colloidal floe. at the optimum coagulants dosage was in the range of -20~-15mV in case of 5 NTU of raw water turbidity and 0~0.5mV in case of 10 NTU of that. respectively. Although the kinds and dosages of coagulants were different, zeta potential range were fixed under the conditions of the best coagulation efficiency.

  • PDF

Water Quality Assessment and Turbidity Prediction Using Multivariate Statistical Techniques: A Case Study of the Cheurfa Dam in Northwestern Algeria

  • ADDOUCHE, Amina;RIGHI, Ali;HAMRI, Mehdi Mohamed;BENGHAREZ, Zohra;ZIZI, Zahia
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.563-573
    • /
    • 2022
  • This work aimed to develop a new equation for turbidity (Turb) simulation and prediction using statistical methods based on principal component analysis (PCA) and multiple linear regression (MLR). For this purpose, water samples were collected monthly over a five year period from Cheurfa dam, an important reservoir in Northwestern Algeria, and analyzed for 12 parameters, including temperature (T°), pH, electrical conductivity (EC), turbidity (Turb), dissolved oxygen (DO), ammonium (NH4+), nitrate (NO3-), nitrite (NO2-), phosphate (PO43-), total suspended solids (TSS), biochemical oxygen demand (BOD5) and chemical oxygen demand (COD). The results revealed a strong mineralization of the water and low dissolved oxygen (DO) content during the summer period. High levels of TSS and Turb were recorded during rainy periods. In addition, water was charged with phosphate (PO43-) in the whole period of study. The PCA results revealed ten factors, three of which were significant (eigenvalues >1) and explained 75.5% of the total variance. The F1 and F2 factors explained 36.5% and 26.7% of the total variance, respectively and indicated anthropogenic pollution of domestic agricultural and industrial origin. The MLR turbidity simulation model exhibited a high coefficient of determination (R2 = 92.20%), indicating that 92.20% of the data variability can be explained by the model. TSS, DO, EC, NO3-, NO2-, and COD were the most significant contributing parameters (p values << 0.05) in turbidity prediction. The present study can help with decision-making on the management and monitoring of the water quality of the dam, which is the primary source of drinking water in this region.

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.