• Title/Summary/Keyword: and quality assurance measurement system

Search Result 79, Processing Time 0.032 seconds

A Designing Method of Network Quality Assurance Test Bed Design under Next-generation Network Environment (NGN(Next Generation Network)의 네트워크 품질 보증을 위한 테스트베드 모델 설계)

  • Chung, Ji Moon
    • Journal of Digital Contents Society
    • /
    • v.13 no.4
    • /
    • pp.625-629
    • /
    • 2012
  • This paper is presented to prepare NGN quality assurance management process under the quality system test methodology. The process should be drawn for NGN quality measurement framework of multimedia traffic. NGN test bed management process model are QoS measurement metrics, measurement interval meter above, and measuring tools, measuring equipment, measurement methods and measurement results from a series of processes for the analysis and methodology. This model, NGN quality assurance activities should be utilized in the future. Quality target level only when themselves constantly measured and managed, does not guarantee the communication quality of service. It is sensitive to the importance of NGN network technology paradigm for research on quality management in the NGN.

Quality Cost Mitigation Strategy through Satellite's Mission Assurance (임무보증활동을 통한 인공위성 품질비용 저감방안)

  • Kim, You-gwang;Lee, Woo-jun;Baek, Myung-jin;Chun, Young-Sik;Lee, Nak-young
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.41-46
    • /
    • 2015
  • The various risk factors that affected schedule, costs and mission success, etc. in development of the satellite. This paper derives the considerable "Cost of Quality" factors in the satellite development phase through the survey of practical techniques in respect of measurement of quality cost in the commercial products manufacturing, and proposes mitigation strategy of quality cost using the approach that can be minimized it.

Definition and Case Study of Effectiveness Metrics for e-Navigation Usability Testing (e-Navigation 사용성 평가를 위한 유효성 메트릭 정의 및 사례)

  • Jung, Jieun;Lee, Seojeong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1338-1346
    • /
    • 2017
  • To achieve software quality and human-centred design for electronic ship navigation called e-navigation, an international guideline of software quality assurance and human-centred design was approved in 2015. Usability is a common goal of both software quality assurance and human-centred design as developing e-navigation system and software developments. Therefore, research is needed to evaluate the usability of e-navigation systems and software such as metrics that can use usability testing. This paper derives effectiveness metrics for e-Navigation usability testing based on international standards. The research method is to analyses and compares the effectiveness measurement and metrics in ISO 9241-11 for human-centered design and ISO/IEC 25022 and 25023 for software quality to find out measurements and metrics being defined commonly. The derived metrics are applied to Electronic Chart Display and Information System as a case study based on performance standard.

Development of Quality Cost Measurement Items in Service Industry (서비스산업에서의 품질비용 측정 항목 도출에 관한 연구)

  • Lee, Maeng-Jeon;Park, Jung-Oun;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • The purpose of this study is to develop measurement items for quality cost in service industries. Quality cost is necessary in order to evaluate quality management activities. It is clear that the quality cost in service industry is different from manufacturing industry. Generally, in service industries, quality cost is very difficult to assess because it has a unique characteristics. This paper proposes an effective method for measuring quality cost in service industries. Based on the PAF (Prevention, Appraisal, Failure) cost model, we utilizes the concept of five demensions in SERVQUAL which are tangibles, reliability, responsiveness, assurance, empathy. This paper also presents to a standard model for quality cost measurement in service industries.

Design of Video Quality Assurance and Integrated Quality Management System using No Reference QoE (비 참조 QoE를 이용한 영상품질 측정 및 통합품질 관리 시스템의 설계)

  • Kim, Sang-Soo;Park, Dong-Soo
    • The Journal of Information Technology
    • /
    • v.12 no.3
    • /
    • pp.49-57
    • /
    • 2009
  • This Paper provides perceptual metrics for video quality based on properties of human visual system, and audio quality based on human audition. All metrics work without reference signals, allowing non-intrusive, in-service measurements. A simple and easy-to-learn user interface displays the metrics and saves them in popular file formats like CSV. In this paper, proposed method was able to various and corrective measurement for the multimedia service video quality. As that it was able to application to set up service guide line and the methode of measurement and system for the set up standardization of the high quality video service.

  • PDF

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.

A Case Study on Developing a Checking System of Gear Parts (기어 부품의 검사시스템 개발에 관한 사례)

  • Yun, Tae-Hong;Byun, Jai-Hyun
    • IE interfaces
    • /
    • v.21 no.4
    • /
    • pp.378-384
    • /
    • 2008
  • Small sized companies have not been successful in systematically applying statistical process control because of insufficient human resources. In this paper we present a case study of automatic checking system for a small sized company which produces various types of gears. A systematic way of automatically measuring gears is proposed and statistical analysis methods are presented. To reduce variation in the measurement data, a standard operating procedure is also proposed. This case study can be helpful to quality assurance practitioners of small sized companies who are willing to develop checking or inspection systems for their products.

Application of slab and plate width measurement using laser distance meter (Laser를 이용한 후물 판재류 및 Slap폭 측정 적용)

  • 최철호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1076-1078
    • /
    • 1996
  • According to ascending needs for quality assurance of plate by customer and automated measurement of dimension for slab, in plate mill, project is on preceeding to install measuring system to measure width, length and camber of slab and plate using laser distance meter. In this document, I will describe not technical point of view but idea of design for installation system.

  • PDF

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

Development of Prototype Quality Assurance Procedure for Blood Irradiator Using Glass Dosimeter Jig (유리선량계 지그를 이용한 혈액조사기의 정도관리 절차 초안 개발)

  • Jeong, Dong-Hyeok;Kang, Yeong-Rok;Moon, Young-Min;Kim, Hyo-Jin;Kwak, Dong-Won;Kim, Jeung-Kee;Lee, Man-Woo
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.123-126
    • /
    • 2012
  • For the purpose of quality assurance (QA) of the blood irradiator, QA programs for daily, monthly, and yearly were developed. For daily tests, simple items for basically operating the machine are recommended. For monthly and yearly tests, the measurement of dose to assure the dose delivery system are performed by a dosimetry devices (Glass dosimeter jig) developed in this study. The QA program is practical for clinical environment.