• Title/Summary/Keyword: and plasma display panel

Search Result 632, Processing Time 0.031 seconds

A Study on the Vibrational Reduction Evaluation and the Relative Displacement in the External Vibration of Precision Measuring System (초정밀 측정/가공 장비의 외부진동에 대한 상대변위의 추출과 진동성능 평가에 관한 연구)

  • 전종균;엄호성;김강부;원영재
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.1
    • /
    • pp.65-72
    • /
    • 2002
  • Generally, there are laser operating equipments( aligner, stepper) and electronic microscope( SEM, TEM) as a high precision manufacturing and inspection equipment in semiconductor production companies, precision examination and measuring laboratories. Mostly, these equipments are characterized by projection and target part. The relative displacements between projection and target part are dominant roles in vibrational problem in these precision equipments. These relative displacements are determined by the position of incoming vibration and the difference of vibration response in projection and target part. In this study, the allowable vibrational limits are suggested and the vibrational reduction plans are proposed by measurement and analysis of vibration phenomenon in the Clean Room in PDP(plasma display panel) production building. The vibration performance is evaluated by comparison relative displacements between projection and target part before/after the vibration isolation plan.

A study on optimal drive waveform and optimal gas mixing ratio of Plasma Display Panel (AC 플라즈마 디스플레이 패널에서의 최적 구동 파형 및 최적 가스 흔합비에 관한 연구)

  • Choi, Hoon-Young;Park, Hun-Gun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1721-1723
    • /
    • 1997
  • In AC Plasma Display Panel(PDP), serious problems are low radiation brightness and very high discharge voltage. To solve these problems, it is necessary to obtain optimal frequency of drive waveform and optimal gas mixing ratio. This paper presents firing voltage and sustain voltage as frequency of waveform and gas mixing ratio, and proposes optimal frequency of drive waveform and optimal gas mixing ratio.

  • PDF

Low Cost Power System Design for Plasma Display Panel(PDP)

  • Yoo, Kwang-Min;Lee, Jun-Young;Lim, Sung-Kyoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.250-255
    • /
    • 2006
  • A low cost PDP sustain power supply is proposed based on flyback topology using Boundary Conduction Mode(BCM) to control input current regulation. This method guarantees DCM condition to regulate the input current harmonics under all load conditions. An excessive voltage stress due to the link voltage increase can be suppressed by removing link capacitor and adjusting transformer turns ratios, which makes it possible to be used for universal line applications. The proposed converter is tested with a 400W(200V-2A output) prototype circuit.

  • PDF

Development of High-definition PDP(Plasma Display Panel) Barrier Ribs Using Watersoluble UV-curing Resin (수용성 UV경화성 수지를 이용한 고품질 PDP용 격벽제작 기술 개발)

  • Nam, Su-Yong;Woo, Jin-Ho;Lee, Mi-Young;Lee, Gab-Hee;Kim, Goang-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2003
  • Barrier ribs for PDP(plasma display panel) are commonly utilized to have uniform height and width and to prevent opical crosstalk between adjacent cells. The requirements for such barrier ribs are uniform height and shape, low outgassing rate and low porosity, high aspect ratio, and fine resolution. In this study, we are studied about that to make efficiency of material and high quality barrier ribs for PDP. As a result, could got high barrier ribs of $140{\mu}m$ evenly in 1th phenomenon using watersoluble UV curing resin and know that flatness of upper part is also very good.

  • PDF

A new high efficiency splitted sustaining driver for plasma display panel (PDP) (새로운 고효율 플라즈마 디스플레이 패널 분할 서스테인 구동 드라이버)

  • Yi Kang-Hyun;Choi Seong-Wook;Moon Gun-Woo;Park Jung-Pil;Jung Nam-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.91-93
    • /
    • 2006
  • A new High Efficiency splitted sustaining driver for Plasma Display Panel (PDP) is proposed. The proposed circuit is suitable for the large screen PDP. The features of the proposed circuit are zen voltage switching (ZVS) of all main power switches, the reduction of reaction power loss for energy recovering, the stable light emission and simple structure.

  • PDF

A new high performance energy-recovery circuit for a plasma display panel (PDP을 위한 새로운 고성능 에너지 회로 회수)

  • Kim, Tae-Sung;Han, Sang-Kyoo;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.399-401
    • /
    • 2005
  • A new high performance energy-recovery circuit (ERC) for a plasma display panel (PDP) is proposed. Two different ERCs are employed on both sides of the PDP, and slow falling and fast rising times are applied. It features a zero voltage switching (ZVS), low electromagnetic interference (EMI), low current stress, high efficiency, no severe voltage notch, reduced sustaining voltage, and high energy-recovery capability.

  • PDF

Sputtering of Magnesium Oxide this film for Plasma Display Panel Application (PDP용 MgO 박막의 스퍼터 연구)

  • Choi, Young-Wook;Kim, Jee-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1732-1734
    • /
    • 2003
  • An MgO thin film sputtering system for the PDP (Plasma Display Panel) applications has been developed. This system was manufactured with a vertical In-Line type of 42 inch, which has the length of 520 mm and the width of 900 mm. A reactive magnetron discharge for this sputtering was generated using an unipolar pulsed power supply which has functions of constant voltage (Max. 500 V) and current (Max. 15 A) control, frequency of $10{\sim}100$ kHz and duty ratio of $10{\sim}60$ %. The experiment was conducted under various conditions : $3{\sim}10$ mTorr of pressure, the ratio of $O_2$/Ar = $0.1{\sim}0.5$, 50 % of duty and power of $0.5{\sim}1.7$ kW. From the experiment, the deposition rate of a static state and a moving state were measured to be about 45 nm/min and 6 nm m/min at the distance of 50 mm between the target and the substrate, respectively.

  • PDF

Optical Diagnostics for Pulse-discharged Plasma by Marx Generator and Its Application for Modifications of Hemoglobin and Myoglobin Proteins

  • Park, Ji Hoon;Attri, Pankaj;Hong, Young June;Park, Bong Sang;Jeon, Su Nam;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.176.2-176.2
    • /
    • 2013
  • Property of optical diagnostics for pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is 0.5 ${\mu}F$, to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of 0.5 ${\mu}F$. High voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ~ 1 ${\mu}s$ between the two electrodes of anode-cathode whose material is made of tungsten pin, which are immersed into the liquids. We have investigated the emitted hydrogen lines for optical diagnostics of high voltage pulsed plasma. The emission line of 656.3 nm from $H-{\alpha}$ and 486.1 nm from $H-{\beta}$ have been measured by a monochromator. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium conditions, the electron temperature and density of the high voltage pulsed plasma in liquid could be obtained by the Stark broadening of optical emission spectroscopy. For the investigation of the influence of pulsed plasma on biological proteins, we have exposed it onto the proteins such as hemoglobin and myoglobin. The structural changes in these proteins and their analysis have also been obtained by circular dichroism (CD) and ultraviolet (UV) visible spectroscopy.

  • PDF

Real time Image Processor for Reproduction of Gray Levels in Dark Areas on Plasma Display Panel (PDP) (플라즈마 디스플레이 패널의 어두운 영역에서의 계조 재현을 위한 실시간 영상처리기)

  • Lee, Chang-Hun;Park, Seung-Ho;Gang, Jin-Gu;Kim, Chun-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.46-54
    • /
    • 2002
  • Plasma Display Panel (PDP) is required to be both the determination of white point of each gray level and the inverse gamma correction since no-balanced RGB cell and linear property of PDP, respectively. However, these two methods cause degradation of grey level representation and undesirable false contour in the dark areas on PDP. In this paper, we implemented real time image processor of the proposed error diffusion algorithm and unsharp masking operation to protect the blurring image caused by the error diffusion. Experimental results showed drastic improvements of gray level representation and reduction of undesirable false contour.

A new Driving Algorithm Design and Implementation for High Efficiency and High Image Quality in PDP (PDP 고효율 고화질 구동 알고리즘 설계 및 FPGA 구현)

  • Cha, Soo-Ik;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes the new subfield method to erase reverse gray levels and low gray level contour in AC plasma display panel(PDP). In the conventional method, it is supposed that output luminance levels of a PDP increase regularly. But actual output luminance levels of a PDP increase irregularly. Therefore, conventional methods are unable to effectively reduce low gray-level contours and reverse gray levels. Accordingly, a new subfield method is applied to improve the low gray-level expression in PDP. Conclusively this paper clear proof that a new subfield method can suppress low gray-level contours and reverse gray levels more effectively than conventional methods.

  • PDF