• Title/Summary/Keyword: and materials

Search Result 97,664, Processing Time 0.124 seconds

Development of Korean Version of Heparin-Coated Shunt (헤파린 표면처리된 국산화 혈관우회도관의 개발)

  • Sun, Kyung;Park, Ki-Dong;Baik, Kwang-Je;Lee, Hye-Won;Choi, Jong-Won;Kim, Seung-Chol;Kim, Taik-Jin;Lee, Seung-Yeol;Kim, Kwang-Taek;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • Background: This study was designed to develop a Korean version of the heparin-coated vascular bypass shunt by using a physical dispersing technique. The safety and effectiveness of the thrombo-resistant shunt were tested in experimental animals. Material and Method: A bypass shunt model was constructed on the descending thoracic aorta of 21 adult mongrel dogs(17.5-25 kg). The animals were divided into groups of no-treatment(CONTROL group; n=3), no-treatment with systemic heparinization(HEPARIN group; n=6), Gott heparin shunt (GOTT group; n=6), or Korean heparin shunt(KIST group; n=6). Parameters observed were complete blood cell counts, coagulation profiles, kidney and liver function(BUN/Cr and AST/ ALT), and surface scanning electron microscope(SSEM) findings. Blood was sampled from the aortic blood distal to the shunt and was compared before the bypass and at 2 hours after the bypass. Result: There were no differences between the groups before the bypass. At bypass 2 hours, platelet level increased in the HEPARIN and GOTT groups(p<0.05), but there were no differences between the groups. Changes in other blood cell counts were insignificant between the groups. Activated clotting time, activated partial thromboplastin time, and thrombin time were prolonged in the HEPARIN group(p<0.05) and differences between the groups were significant(p<0.005). Prothrombin time increased in the GOTT group(p<0.05) without having any differences between the groups. Changes in fibrinogen level were insignificant between the groups. Antithrombin III levels were increased in the HEPARIN and KIST groups(p<0.05), and the inter-group differences were also significant(p<0.05). Protein C level decreased in the HEPARIN group(p<0.05) without having any differences between the groups. BUN levels increased in all groups, especially in the HEPARIN and KIST groups(p<0.05), but there were no differences between the groups. Changes of Cr, AST, and ALT levels were insignificant between the groups. SSEM findings revealed severe aggregation of platelets and other cellular elements in the CONTROL group, and the HEPARIN group showed more adherence of the cellular elements than the GOTT or KIST group. Conclusion: Above results show that the heparin-coated bypass shunts(either GOTT or KIST) can suppress thrombus formation on the surface without inducing bleeding tendencies, while systemic heparinization(HEPARIN) may not be able to block activation of the coagulation system on the surface in contact with foreign materials but increases the bleeding tendencies. We also conclude that the thrombo-resistant effects of the Korean version of heparin shunt(KIST) are similar to those of the commercialized heparin shunt(GOTT).

  • PDF

Gene Expression Profiles in Cervical Cancer with Radiation Therapy Alone and Chemo-radiation Therapy (자궁경부암의 방사선치료 및 방사선항암화학 병용치료에 따른 유전자발현 조절양상)

  • Lee Kyu Chan;Kim Meyoung-kon;Kim Jooyoung;Hwang You Jin;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.54-65
    • /
    • 2003
  • Purpose : To analyze the gene expression Profiles of uterine ceulcal cancer, and its variation after radiation therapy, with or without concurrent chemotherapy, using a CDNA microarray. Materials and Methods :Sixteen patients, 8 with squamous ceil carcinomas of the uterine cervix, who were treated with radiation alone, and the other 8 treated w14h concurrent chemo-radiation, were Included in the study. Before the starling of the treatment, tumor biopsies were carried out, and the second time biopsies were peformed after a radiation dose of 16.2$\~$27 Gy. Three normal cervix tissues were used as a control group. The microarray experiments were peformed with 5 groups of the total RNAs extracted individually and then admixed as control, pre-radiation therapy alone, during-radiation therapy alone, pre-chemoradiation therapy, and during-chemoradlation therapy. The 33P-iabeled CDNAS were synthesized from the total RNAs of each group, by reverse transcription, and then they were hybridized to the CDNA microarray membrane. The gene expression of each microarrays was captured by the intensity of each spot produced by the radioactive isotopes. The pixels per spot were counted with an Arrayguage, and were exported to Microsoft Excel The data were normalized by the Z transformation, and the comparisons were peformed on the Z-ratio values calculated. Results : The expressions of 15 genes, including integrin linked kinase (ILK), CDC28 protein kinase 2, Spry 2, and ERK 3, were increased with the Z-ratio values of over 2.0 for the cervix cancer tissues compared to those for the normal controls. Those genes were involved In cell growth and proliferation, cell cycle control, or signal transduction. The expressions of the other 6 genes, Including G protein coupled receptor kinase 5, were decreased with the Z-ratio values of below -2.0. After the radiation thorapy, most of the genes, with a previously Increase expressions, represented the decreased expression profiles, and the genes, with the Z-ratio values of over 2.0, were cyclic nucleotlde gated channel and 3 Expressed sequence tags (EST). In the concurrent chemo-radiation group, the genes involved in cell growth and proliferation, cell cycle control, and signal transduction were shown to have increased expressions compared to the radiation therapy alone group. The expressions of genes involved in anglogenesis (angiopoietln-2), immune reactions (formyl peptide receptor-iike 1), and DNA repair (CAMP phosphodiesterase) were increased, however, the expression of gene involved In apoptosls (death associated protein kinase) was decreased. Conclusion : The different kinds of genes involved in the development and progression of cervical cancer were identified with the CDNA microarray, and the proposed theory is that the proliferation signal stalls with ILK, and is amplified with Spry 2 and MAPK signaling, and the cellular mitoses are Increased with the increased expression oi Cdc 2 and cell division kinases. After the radiation therapy, the expression profiles demonstrated 4he evidence of the decreased cancer cell proliferation. There was no sigificant difference in the morphological findings of cell death between the radiation therapy aione and the chemo-radiation groups In the second time biopsy specimen, however, the gene expression profiles were markedly different, and the mechanism at the molecular level needs further study.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

A Study of the Impractical Area and Boundary of an Outer Royal Garden "Hamchunwon" Attached to Gyeonghuigung Palace (경희궁 별원(別苑) 함춘원의 실지(實地) 경역 고찰)

  • Jung, Woo-Jin;Hong, Hyeon-Do;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.26-42
    • /
    • 2022
  • The purpose of this study is to examine and understand the area and the original outer boundaries of Hamchunwon(含春苑), which was the outer royal garden of Gyeonghuigung Palace, which existed before the site of the Russian legation. The results of the study are as follows. First, examining the 3 types of drawings prepared for securing the Russian legation's site and constructing a new building, it was confirmed that two low peaks, which appear to be the original terrain of Hamchunwon, existed in the north and south directions inside the site. According to the initial plan of the of the legation's site, it appears that the entrance of the legation building is connected to the Saemunan-ro in the northwest. However, according to the report made at the time when the Russian temporary minister Veber purchased the legation's site, it was recorded that the site already had a narrow entrance and a dirt road in place, and hence, it was connected to Saemunan-ro. This fact makes it possible to learn that the line of movement for officials and the original gate were located to the northwest of the site planned as the entrance of the legation building towards Hamchunwon. Second, the site was created by cutting the top of the high hill at the time of the construction of the legation building, and as a result, a two tiered staircase typed terrace was built. The ground on which the main building and the secretary's building, etc., were erected was made by cutting the highest peak and solidifying it flat, and a large quantity of soil was used for grading. In the case of the northern area of the main building, the traces of leveling the terrain by cutting the mountains are apparent, and an observation typed garden with a walking path and pavilion was formed by utilizing the physical environment equipped with an easy view. This may be considered as a use which is consistent with the topographical conditions of creating an outer royal garden to block the civilian views on a high terrain overlooking the palace. Third, Hamchunwon's fences were partially exposed in the photos from the 1880s through the 1890s, which demonstrate the spatial changes made around the US, UK, and the Russian legations. As a result of the photo analysis performed, Hamchunwon occupies the northern area of the Russian legation's site, and it is estimated that the north, west, and east walls of the legation resembled those of Hamchunwon. The area to the south of the Russian legation was originally a place made available for civilian houses, and it was possible to examine the circumstances of purchasing dozens of civilian houses and farmlands according to various materials. Fourth, Hamchunwon, which was formed as the outer royal garden of Gyeongdeokgung Palace of Lord Gwanghaegun, lost its sense of place as an outer royal garden when the entire building of Gyeonghuigung Palace was torn down and used as a construction members during the reconstruction of Gyeongbokgung Palace, and faded away as the site was sold to Russia around 1885. The area where Hamchunwon used to be located transformed into a core space of the Russian legation where the main building and garden were located after the construction of the new building. Hence, Hamchunwon, which was limited to the northern area of the Russian legation, does not carry the temporal and spatial context with Gyeongungung Palace and Seonwonjeon which were constructed after 1897, and it is determined that the view of Seonwonjeon as Baehoorim or Baegyeongrim is not valid.

Influence of Nutritional Supplementation to the Substrate on Vegetative and Reproductive Growth of Winter Mushroom, Flammulina velutipes (Curt. ex Fr.) Sing. and Chemical Changes of the substrates Produced during Growth of the Fungus (톱밥 배지(培地)에 대(對)한 영양첨가(營養添加)가 팽이버섯의 생장(生長)및 배지(培地)의 화학적(化學的) 성분(成分) 변화(變化)에 미치는 영향(影響))

  • Chang, Hak-Gil
    • The Korean Journal of Mycology
    • /
    • v.4 no.1
    • /
    • pp.31-44
    • /
    • 1976
  • The studies were carried out to examine the effects of supplementation of nutritional substances and physical conditions in substrate on the mycelial growth and yield of fresh sporophores of winter mushroom, Flammulina velutipes(Curt. ex Fr.) Sing. and to obtain further informations on the nutritional requirements of the fungus with reference to improvement of substrate through [analysis of chemical composition of the substrates during the cultivation period. The results obtained are summarized as follows: 1. The best yield of fresh sporophores, 84.4 g per 280 g substrate in a bottle, was obtained from the mixture of poplar sawdust 10 and rice bran 3 by volume when Flammulina velutipes was cultivated on the poplar sawdust supplemented by rice bran, wheat bran, cattle manure and various combinations of these materials as nutrient sources. The substrates of poplar sawdust 10 plus rice bran 3 and 2 or wheat bran 3 with a higher yield of fresh sporophores showed a comparatively higher content of total nitrogen. total sugar, and potassium. 2. The mycelial growth of the fungus was compared on the substrates of poplar sawdust supplemented by the several nutrient sources and poplar sawdust alone. The fastest linear growth occurred on substrates of poplar sawdust alone and poplar sawdust plus cattle manure deficient in sugar and nitrogen sources, but mycelial density was more sparse on the substrates. Also, growth in a solution extracted from these substrates was very meager. 3. In the substrates which varied with bulk density and moisture content optimum bulk density and moisture content for mycelial growth was 0.2g/cc and 72% on a dry weight basis, respectively, but the highest yield of fresh sporophores was obtained at the bulk density of 0.3g/cc and moisture content of 67%. 4. By increasing the ratio of rice bran in poplar sawdust the loss of total weight and ash, content at each stage was increased, and during the cultivation period of 75 days, loss of total weight of the substrates at inoculation was 17.8 to 28.8% and ash content increased about 12%. 5. 11 to 14% of the cellulose and 3 to 4% of the lignin content per original substrate were decreased without a great difference depending of the mixing ratio of rice bran. The soluble glucose concentration in the substrates was increased during the same period. 6. In the process of vegetative and reproductive growth of the fungus upon the substrates, the total nitrogen was increased in quantity per dry weight of sample but was reduced in absolute quantity to a minute extent. There is no great changes in content of organic nitrogen including amino acid nitrogen, and hydrolysable ammonium nitrogen during the vegetative growth period, but occurrence of sporophores resulted in a decrease in the nitrogen content of these forms. On the one hand, by an increase of additive amounts of rice bran, nitrogen contents of these forms were higher and the reduction range during the reproductive growth period became wider. 7. Mycelial growth of the fungus was accelerated in various liquid media supplemented with organic nitrogen sources such as peptone and yeast extract in comparison with addition of inorganic nitrogen sources. Furthermore, mycelial growth was mere vigorous in the media with higher content of organic nitrogen sources.

  • PDF

Meteorological Constraints and Countermeasures in Rice Breeding -Breeding for cold tolerance- (기상재해와 수도육종상의 대책 - 내냉성품종육성방안-)

  • Mun-Hue Heu;Young-Soo Han
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.4
    • /
    • pp.371-384
    • /
    • 1982
  • Highly cold tolerant varieties are requested not only at high latitute cool area but also tropical high elevated areas, and the required tolerance is different from location to location. IRRI identified 6 different types of cold tolerance required in the world for breeding purpose; a) Hokkaido type, b) Suweon type, c) Taipei 1st season type, d) Taipei 2nd season type, e) Tropical alpine type and, f) Bangladesh type. The cold tolerance requested in Korea is more eargent in Tongil group cultivars and their required tolerance is the one such as the physiological activities at low temperature are as active as in Japonica group cultivars at least during young seedling stage and reproduction stage. With conventional Japonica cultivars, such cold tolerant characters are requested as short growth duration but stable basic vegetative growth, less sensitive to high temperature and less prolonged growth duration at low temperature. The methods screening for cold tolerance were developed rapidly after the Tongil cultivar was reliesed. The facilities of screening for cold tolerance, such as, low temperature incubator, cold water tank, growth cabinet, phytotron, cold water nursery in Chuncheon, breeding nursery located in Jinbu, Unbong and Youngduk, are well established. Foreign facilities such as, cold water tank with the rapid generation advancement facilities, cold nurseries located in Banaue, Kathmandu and Kashimir may be available for the screening of some limitted breeding materials. For the reference, screening methods applied at different growth stages in Japan are introduced. The component characters of cold tolerance are not well identified, but the varietal differences in a) germinability, b) young seedling growth, c) rooting, d) tillering, e) discolation, f) nutrition uptake, g) photosynthesis rate, h) delay in heading, i) pollen sterility, and j) grain fertility at low temperature are reported to be distinguishable. Relationships among those traits are not consistent. Reported studies on the inheritance of cold tolerance are summarized. Four or more genes are controlling low temperature germinability, one or several genes are controlling seedling tolerance, and four or more genes are responsible for the pollen fertility of the rice treated with cold air or grown in the cold water nursery. But most of those data indicate that the results may come out in different way if those were tested at different temperature. Many cold tolerant parents among Japonicas, Indicas and Javanicas were identified as the results of the improvement of cold tolerance screening techniques and IRTP efforts and they are ready to be utilized. Considering a) diversification of germ plasm, b) integration of resistances to diseases and insects, c) identification of adaptability of recommending cultivars and, d) systematic control of recommending cultivars, breeding strategies for short term and long term are suggested. For short term, efforts will be concentrated mainly to the conventional cultivar group. Domestic cultivars will be used as foundation stock and ecologically different foreign introductions such as from Hokkaido, China or from Taiwan, will be used as cross parents for the adjustment of growth durations and synthsize the prototype of tolerances. While at the other side, extreme early waxy Japonicas will be crossed with the Indica parents which are identified for their resistances to the diseases and insects. Through the back corsses to waxy Japonicas, those Indica resistances will be transfered to the Japonicas and these will be utilized to the crosses for the improvement of resistances of prototype. For the long term, efforts will be payed to synthsize all the available tolerances identified any from Japonicas, Indicas and Javanicas to diversify the germ plasm. The tolerant cultivars newly synthsized, should be stable and affected minimum. to the low temperature at all the growing stages. The resistances to the diseases and insects should be integrated also. The rapid generation advancement, pollen culture and international cooperations were emphasized to maximize the breeding efficiency.

  • PDF

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF