• Title/Summary/Keyword: and VP9

Search Result 211, Processing Time 0.032 seconds

Effective dose from direct and indirect digital panoramic units

  • Lee, Gun-Sun;Kim, Jin-Soo;Seo, Yo-Seob;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • Purpose: This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Materials and Methods: Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. Results: The effective doses of the 4 digital panoramic units ranged between $8.9{\mu}Sv$ and $37.8{\mu}Sv$. By using the head phantom, the effective doses from the direct digital panoramic units ($37.8{\mu}Sv$, $27.6{\mu}Sv$) were higher than those from the indirect units ($8.9{\mu}Sv$, $15.9{\mu}Sv$). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. Conclusion: To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

Simultaneous infection with rabbit hemorrhagic disease virus and Pasteurella multocida in rabbits

  • Lee, Yun Chan;Oh, Yeonsu;Choi, Sang Ho;Chae, Mi Kyung;Na, Ki Bok;Yook, Sim Yong;Han, Jeong Hee
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • Rabbit infectious hemorrhagic fever has been reported in rabbits worldwide. The disease is also frequently reported on Korean rabbit farms, and the pathological study of 9 rabbits on such disease-occurring farms was attempted to identify the pathogen. Clinical signs were torticollis and ear ulceration. Most rabbit died with bloody nasal discharges. At necropsy, multiple hemorrhages and inflammation were observed in heart, lung, liver and uterus. The main histopathologic features were hemorrhagic suppurative meningoencephalitis, fibrinous bronchointerstitial pneumonia, bacteremia, liver cell necrosis, multifocal hemorrhages in kidney and disseminated intravascular coagulopathy. The viral VP60 gene of RHDV was identified by Reverse Transcriptase PCR. Pasteurella multocida organisms were cultured, identified by biochemical test and serotyped as A by multiplex capsular typing PCR. In conclusion, the fatal hemorrhagic disease was due to combined infection with both RHDV and P. multocida in rabbits. To our knowledge, this is the first case report about co-infection with both RHDV and P. multocida in rabbits in Korea.

Studies on the production and characterization of monoclonal antibodies against bovine rotaviruses isolated in Korea (소 로타바이러스(국내분리주)에 대한 단크론항체 생산 및 특성에 관한 연구)

  • Ahn, Jae-moon;Cho, Sun-hee;Kang, Shien-young
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.2
    • /
    • pp.395-403
    • /
    • 1996
  • Monoclonal antibodies(MAbs) against field isolates of the bovine rotavirus A strain(G6), V strain(G10) and reference I-801 strain(G8) were produced and characterized. Six MAbs(4C2, 4D9, 5E1, 5E7, 5D5, 3E4) against A strain had neutralizing activity and reacted only with the G6 bovine rotaviruses determined by fluorescence focus neutralization (FFN) test. Otherwise, five neutralizing MAbs(1G2, 2G6, 5E2, 5E12, 5H7) against I-801 strain neutralized the G6 and G8 bovine rotaviruses. Five non-neutralizing MAbs(5F12, 7F12, 5E11, 2A11, 2B12) were VP6-specific and cross-reacted with all bovine and porcine rotaviruses examined by fluorescence antibody(FA) test. None of the MAbs reacted with bovie viral diarrhea virus(BVDV) and bovine coronavirus(BCV) determined by FA and FFN test.

  • PDF

Evaluating polyester resin as a viable substitute for PMMA in computed tomography dosimetry phantoms

  • A. Khallouqi;A. Halimi;O. El rhazouani
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3758-3763
    • /
    • 2024
  • The current study aimed to evaluate the suitability of polyester resin as an alternative material to polymethyl methacrylate (PMMA) for computed tomography (CT) dosimetry phantoms using the GEANT4/GATE Monte Carlo simulation platform. Cylindrical phantoms (32 cm diameter) constructed of polyester resin and PMMA were simulated and compared in terms of atomic composition, effective atomic number, electron density, mass density, and photon interaction mechanisms. Weighted CT dose index (CTDIw) values were calculated for each phantom at 80, 110, and 130 kVp tube voltages based on measurements of CTDI100,c and CTDI100,p. Results demonstrated that the physical properties of polyester closely matched those of PMMA, and the polyester phantom displayed equivalent dosimetric behavior to the PMMA phantom at all tube voltages tested. CTDIw values from the polyester phantom were within 1.4 % of the PMMA phantom across all tube voltages. Conversion coefficients were derived to equate polyester CTDIw values to PMMA dose equivalents. This study found that a polyester resin phantom exhibited radiation dosimetry commensurate with the standard PMMA phantom for CT dose assessment. Consequently, polyester resin represents a viable substitute material when PMMA is unavailable for construction of CT dosimetry phantoms.

A Study on Removal Performance of $NH_3$ Odor Gas Using High Frequency Surface Discharge Body (고주파 연면방전체를 이용한 $NH_3$ 처리성능에 관한 연구)

  • 이주상
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 1996
  • The purpose of this study was to evaluate the decomposition efficiency of $NH_3$ odor gas using high frequency surface discharge body. The results from this study are as follows; 1, Voltage and frequency of electric elements have effects on removal of $NH_3$ odor. The higher these two elements were set up, the more efficiently deodorizing processing worked. In this experiment, the optimum voltage and frequency applicable were observed around AC 6.0 kVp-p and 24.0 kHz respectively. 2. The temperature, humidity and residence time were observed strong variables for NH$_3$ removal process. Its performance had limits at high temperature and humidity conditions. The longer the residence time continued, the more efficiently deodorization process worked. The experimental results showed that the deodorization was efficiently processed under such conditions as $30.0^{\circ}C$ in temperature, 60rh% in humidity and 0.3 sec in residence time. 3. It was observed that in deodorization experiment, $NH_3$ odor gas was perfectly decomposed under the concentration condition below 15.0ppm. Moreover it was considered as economic and practical in terms of maintenance cost when compared with other deodorization methods.

  • PDF

The Study on Quantum Efficiency of $CaWO_4$ Screen with Diagnostic X-ray (진단 X선에 대한 $CaWO_4$ 증감지의 양자효율 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.379-382
    • /
    • 2002
  • Lately, intensifying screen of the $CaWO_4$ is used to medical treatment and diagnosis of the image. In this paper, we investigated transmission fraction and mass attenuation coefficient of $CaWO_4$ screen about diagnostic x-ray of low energy using MCNP 4C code. Experimentally, for 0.9 mm-$CaWO_4$ screen, the absorbable rate of diagnostic x-ray is more than 95%. according to kVp, the experimental value of mass attenuation coefficient is in a1most agreement with an corrected estimate value of MCNP and the deviation of experimental values is less than ${\pm}7%$. Using the MCNP code through this paper, we can make an estimate of signal and design for construction of the CaWO4/a-Se based digital x-ray image detector and make a good use of the foundation data for development of other materials.

  • PDF

An empirical study on the X-ray attenuation capability of n-WO3/n-Bi2O3/PVA with added starch

  • Oliver, Namuwonge;Ramli, Ramzun Maizan;Azman, Nurul Zahirah Noor
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3459-3469
    • /
    • 2022
  • Matrix composites of n-WO3/n-Bi2O3/PVA with different loadings of n-WO3/n-Bi2O3 mixtures (0-15 wt%) and starch (0 and 3 wt%) were fabricated by using melt-mixing method. The X-ray attenuation capability were evaluated based on mass attenuation coefficient (μ/⍴) using a general diagnostic X-ray machine at 40-100 kVp. The effect of starch addition on the dispersion of the fillers in the PVA matrix were observed by using FESEM through morphological analysis. The fabricated samples have shrunken and caused their thickness to be decreased (0.35 mm-0.55 mm) after the drying process even though fixed thickness (2.0 mm) was set initially. The density and HVL values of the samples with 3 wt% starch was seen lower than samples without starch (0 wt%), however the former have provided improvement in filler dispersion and better X-ray attenuation capability compared to the latter. As conclusion, the matrix composite of n-WO3/n-Bi2O3/PVA with 15 wt% of n-Bi2O3, 8 wt% of n-WO3 and 3 wt% starch can be selected as the best promising candidate for X-ray shielding materials.

Analyze of Hepatitis A Virus Genotypes in Eastern Area of Jeonnam, Korea

  • Seo, Min-Young;Lee, Hyeok-Jae;Han, Weon-Dong
    • Biomedical Science Letters
    • /
    • v.17 no.1
    • /
    • pp.27-37
    • /
    • 2011
  • Hepatitis A virus (HAV) is a causative agent of triggering acute hepatitis which is transmitted by person-to-person contact and or fecal-oral route. In previous studies, most hepatitis A virus (HAV) isolates had been genotype IA in Korea. Recently, a small number of different genotypes were reported with an upsurge of acute hepatitis by HAV. Therefore, the distribution of HAV genotypes was investigated. RNA was extracted from anti-HAV IgM positive sera which were collected from February to August 2009, at a tertiary care hospital in eastern Jeonnam, Korea. Nested reverse transcription PCR and direct sequencing for VP1/P2A region of the HAV were performed. A total of 365 cases with suspected acute hepatitis were tested for anti-HAV IgM and positive results were obtained in 24 sera (9.0%), which were collected 2 to 15 days (median, 7 days) after the onset of symptoms. Of the 24 seropositive samples, 14 (58.3%) samples were positive for HAV RNA, among which 4 isolates (28.6%) were genotype IA and the other 10 (71.4%) were genotype IIIA. Both IA and IIIA genotypes were isolated from 5~6 neighboring administrative districts throughout the year without geographic or seasonal restrictions. HAV genotypes (IA and IIIA) were observed from the eastern Jeonnam for the studied.

A Study on Application of Non-Destructive Equation for the Estimation of Concrete Strength (콘크리트의 압축강도 추정을 위한 비파괴시험식의 활용성 검토에 관한 연구)

  • Kim, Moo-Han;Kwon, Young-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.129-136
    • /
    • 1999
  • In this paper, the new non-destructive equation will be proposed and evaluated in comparison to the other foreign's non-destructive equation. Through the comparisons cores strength of mock structure with compressive strength obtained from new non-destructive equation ; rebound hammer, ultra-sonic pulse velocity and combined method, it will be analyzed about application of non-destructive equation. The results are following. The new non-destructive equations follow ; (1) $F_c=9.5R{\cdot}N+62.5$ (2) $F_c=243Vp-739$ (3) $F_c=8.1R_o+205.3V_p-802$ where, $F_c$ : Compressive Strength, $R_o$ : Rebound Number. $V_p$ : Ultra-Sonic Pulse Velocity Trough the result of mock structure test, the combined method is superior to rebound method and ultra-sonic pulse velocity method in the estimation of concrete strength. In order to apply the non-destructive equation of concrete strength to the structures, it is necessary that we should be made process study on the non-destructive equation for estimation of concrete strength in the range, time and strength of application under long-term.

  • PDF

Design and Implementation of IP-TV Set-Top Box for IP-TV Service (IP-TV서비스를 위한 IP-TV Set-Top Box설계와 구현)

  • Park, Hyung-Do;Lee, Kyoung-Won;Ahn, Chang-Won;Kim, Dae-Jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.171-174
    • /
    • 2006
  • 본 논문에서는 IP-TV 보금을 위해서 고성능 저가의 IP-TV(Internet Protocol TV) 셋탑박스의 필요성을 감안하여 TV를 통한 인터넷 컨텐츠 이용에 최적화된 IP-TV 셋탑박스를 제조업체(Ninelanes)와 공동으로 개발하였다. 개발된 셋탑박스는 브로드밴드를 이용한 VOD서비스, 1Mbps급의 DVD급 화질을 지원하고 스트리밍 비디오와 저장된 콘텐츠를 직접 재생할 수 있다. 개발된 셋탑박스는 VHS(450kbps), DVD급(750kbps), DVD(1.2Mbps), MP3, AC3, MPEG-2/4, VP4/5/6, WMV9, DVIX 등의 다양한 디지털 미디어 재생 포맷을 지원 할 수 있도록 개발되어 가격경쟁력 향상 및 멀티미디어 지원환경 구축, 인코더방식의 코덱 전환이 가능하다. 또한 고집적, 저전력, 고성능, 저가형 개발 개념으로 개발된 이 셋탑박스는 각종 IP-TV기능을 펌웨어나 소프트웨어 수정으로 시스템 변경이 가능하여 IP-TV 셋탑박스 보급에 크게 기여할 것으로 기대된다.

  • PDF