• 제목/요약/키워드: anatomical landmark

검색결과 40건 처리시간 0.034초

Morphologic Diversities of Sacral Canal in Children;Three-Dimensional Computed Tomographic Study

  • Kim, Dae Wook;Lee, Seung Jun;Choi, Eun Joo;Lee, Pyung Bok;Jo, Young Hyun;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • 제27권3호
    • /
    • pp.253-259
    • /
    • 2014
  • Background: Caudal block is a common technique in children for reducing postoperative pain, and there have been several reports on the variations of the sacral canal in children. However, previous studies have mainly focused on the needle trajectory for caudal block, and there is limited information on the structural variations of the sacrum in children. The purpose of this study was to analyze the anatomic variations of sacral canals in children. Methods: Three-dimensional computed tomographic images were analyzed. The data from the images included (1) fusion of the sacral vertebral laminae and the sacral intervertebral space (2) existence of the sacral cornua and (3) the types of sacral hiatus. The types of sacral hiatus were classified into 3 groups: group I (fusion of S3 or S4 vertebral laminae), group II (unfused vertebral arch with the distance of the S3 and S4 vertebral laminae < 50% of the distance between the cornua), and group III (unfused vertebral arch with the distance of the S3 or S4 vertebral laminae ${\geq}50%$ of the distance between the cornua). Results: A total of 143 children were included in this study. All of the sacral vertebral arches were not fused in 22 children (15.4%). Cornua were not identified bilaterally in 5 (3.5%) and unilaterally in 6 (4.2%) children. In the sacral hiatus, group II and group III were identified in 22 (15.4%) and 31 (21.7%) children, respectively. Conclusions: The sacral canal has various anatomical variations in children. Careful attention must be paid to identify the correct anatomic landmark.

New insight into the vasto-adductor membrane for safer adductor canal blockade

  • Yanguk Heo;Miyoung Yang;Sung Min Nam;Hyun Seung Lee;Yeon-Dong Kim;Hyung-Sun Won
    • The Korean Journal of Pain
    • /
    • 제37권2호
    • /
    • pp.132-140
    • /
    • 2024
  • Background: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB). Methods: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume. Results: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery. Conclusions: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.

한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석 (Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean)

  • 최성;지승민;황성문;신동주
    • 대한정형외과학회지
    • /
    • 제56권6호
    • /
    • pp.498-503
    • /
    • 2021
  • 목적: 컴퓨터 단층 촬영 영상을 이용하여 한국인에서 상완골 근위부 골절 치료에 적용되는 직선형 전향적 상완골 골수 내 금속정의 이상적 삽입점 위치를 알아보고 해부학적 적합성을 분석하고자 한다. 대상 및 방법: 2014년 5월부터 2016년 10월까지 견관절 외상으로 컴퓨터 단층 촬영을 시행한 환자 중 건측 견관절을 동시에 촬영한 한국인 74예를 대상으로 하였으며, 평균 나이는 64.5세(범위, 22-95세)였다. 영상의학적 평가는 건측 근위 상완골의 컴퓨터 단층 촬영 영상을 이용하여 다면 재구성(multiplanar reconstruction) 기법을 이용하였다. 직선형 골수정의 이상적 삽입점은 상완골 골수강 내 중심축과 상완골두가 만나는 점으로 선정하였으며 삽입점과 국소 해부학적 위치와의 거리를 측정하였다. 삽입점에서 극상건 부착부의 가장 내측까지의 관상면상 거리를 임계거리(critical distance)로 정의하고 이를 이용하여 삽입점과 회전근개 부착부와의 근접성을 평가하였다. 회전근개의 손상을 피하고 충분한 고정력을 얻기 위한 임계거리는 Euler 등이 제시한 대로 8mm 이상 확보 되어야 하며, 8 mm 미만인 경우를 위험형(critical type)으로 정의하였다. 임계거리와 성별, 나이, 키, 몸무게, 신체용적지수(body mass index)와의 통계적 유의성을 확인하였다. 결과: 이 연구에서 이상적인 삽입점의 위치는 이두구 외측연에서 시상면상 거리인 전후 거리는 평균 11.5 mm (범위, 4.0-16.6), 대결절의 가장 외측연에서 관상면상 거리인 내외 거리는 평균 20.5 mm (범위, 16.3-27.4)였다. 이상적 삽입점에서 극상건 부착부의 가장 내측까지의 관상면상 거리인 임계거리는 평균 8.0 mm (범위, 4.1-16.6)이며, 임계거리가 8 mm 미만인 위험형(critical type)ㅏ이은 74예 중 41예(55.4%)였다. 결론: 한국인에서 직선형 전향적 상완골 골수 내 금속정의 사용시, 상완 이두구의 외측연에서 후방으로 11.5 mm, 대결절 외측연에서 내측으로 20.5 mm 지점이 평균적인 이상적 삽입점의 위치였다. 하지만 55.4%의 경우에서 이상적 삽입점의 위치로 삽입할 경우 회전근개의 손상을 줄 수 있는 위험형(critical type)이였으므로, 술 전 치료방법의 선택 과정에서 환자 개개인의 해부학적 특성을 충분히 고려하여야 한다.

원위부 전대뇌 동맥류 수술의 실마리 (Surgical Clues of Distal Anterior Cerebral Artery(DACA) Aneurysms)

  • 김승범;이형중;김재민;백광흠;김충현;오석전
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1555-1562
    • /
    • 2000
  • 목 적 : 원위부 전대뇌 동맥에 발생하는 동맥류는 모동맥의 확보가 힘들고 재출혈 및 수술중 조기출혈의 빈도가 높으며, 익숙치 않은 수술적 접근법이 필요하다든지 하는 몇 가지 독특한 문제점이 있다. 따라서 전대뇌 반구간열 주변의 해부학적 구조물과 박리 시작점에 대한 수술전 지식을 요한다. 저자들은 박리 시작점에 대한 일관된 외부표식자를 이용하여 전두 기저부 대뇌반구간열 접근법 수술을 시행하였고 이를 심부 구조물들에 대한 접근 지표로 삼고자 하였다. 대상 및 방법 : 1995년 11월부터 1999년 6월까지 동맥류경을 결찰한 총 131명의 뇌동맥류파열 환자 중에서 원위부 전대뇌 동맥류 9명에 대하여 혈관조영술, 의무기록지, 수술소견을 통해 임상적, 수술소견을 조사하였다. 결 과 : 원위부 전대뇌동맥류의 빈도는 6.3%였고, 6례에서 뇌량 연변 동맥이 기시하는 뇌량 주위 동맥에서 발생하였고, 3례에서는 전두극동맥이 기시하는 뇌량 주위 동맥에서 발생하였다. 동반된 다른 혈관기형 및 다른 동맥류는 각각 3예에서 발견되었다. 술전 환자 상태는 일반적으로 불량했다. 조기수술은 7예에서 실시되었으며, 전두 기저부 대뇌반구간열 접근법으로 동맥류 결찰을 시행한 경우도 7예였다. 술후 심한 혈관연축과 흡인성 폐렴으로 인한 사망이 각각 1례씩이었으며 그 이외에는 신경학적 소견은 정상이었다. 결 론 : 원위부 전대뇌 동맥류의 조기수술시에 전두 기저부 대뇌반구간열 접근법이 유용하였다. 이 방법으로 뇌견인을 최소화할 수 있었으며 동맥류의 조기파열을 방지할 수 있었다. 저자들은 대뇌반구 간열의 박리 시작점으로 첫번째 교정맥(전두극 정맥)이 상시상 정맥동으로 유출되는 지점을 기준으로 하여 뇌량 및 뇌량 주변부 원위부 전대뇌동맥류에 접근할 수 있었다.

  • PDF

PET/CT 장치의 감마선 검출과정 (Gamma Ray Detection Processing in PET/CT scanner)

  • 박성옥;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.125-132
    • /
    • 2006
  • SPECT camera와 PET scanner 그리고 PET/CT 장치는 감마선을 검출하여 얻어진 자료(data)를 정보화 한다. 특히 PET/CT 장치는 PET영상에서 나타나는 해부학적 불선예함을 CT로 보완하여 선예한 해부학적 구조의 영상 묘출능력이 뛰어나 양질의 진단정보를 제공하고 있게 되었다. 신속 정확한 자료의 획득과 정보화를 위하여 우선적으로 검출기(detector)에서의 효율적인 감마선검출은 매우 예민하고 중요한 역할 중의 하나이다. 섬광체(scintillator)의 개발과 함께 data 처리를 위한 software의 발전은 영상재구성처리시간의 단축은 물론 영상의 질적인 향상을 초래하였다. PET scanner에서는 SPECT camera의 $100{\sim}200\;keV$와는 달리 511 keV의 고에너지 감마선을 검출한다. 섬광체 GSO, LSO는 PET scanner의 섬광체로 비교적 많이 이용되고 있다. 고에너지 감마선에너지를 빛으로 전환하여 여러 단계를 거쳐 정보화하는 과정은 결과적으로 고화질의 영상을 비롯한 정확하고 신속한 진단정보획득에 목적을 두고 있다. 화질의 질적향상은 획득한 정보량에 대한 영상의 재구성 방법과 기술에 따라 영향을 받는다. 본 연구는 PET/CT 장치에서 특히 PET부분에서 섬광체(scintillator)의 특성과 감마선의 검출과정에서부터 영상 재구성단계까지 문헌적 고찰을 통하여 요약 설명하였다.

  • PDF

대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단 (Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9)

  • 장대환;최덕주;이범우;박원;한창순;김학산;김종순
    • 대한핵의학회지
    • /
    • 제22권1호
    • /
    • pp.83-92
    • /
    • 1988
  • The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  • PDF

Radiologic assessment of the optimal point for tube thoracostomy using the sternum as a landmark: a computed tomography-based analysis

  • Jaeik Jang;Jae-Hyug Woo;Mina Lee;Woo Sung Choi;Yong Su Lim;Jin Seong Cho;Jae Ho Jang;Jea Yeon Choi;Sung Youl Hyun
    • Journal of Trauma and Injury
    • /
    • 제37권1호
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose: This study aimed at developing a novel tube thoracostomy technique using the sternum, a fixed anatomical structure, as an indicator to reduce the possibility of incorrect chest tube positioning and complications in patients with chest trauma. Methods: This retrospective study analyzed the data of 184 patients with chest trauma who were aged ≥18 years, visited a single regional trauma center in Korea between April and June 2022, and underwent chest computed tomography (CT) with their arms down. The conventional gold standard, 5th intercostal space (ICS) method, was compared to the lower 1/2, 1/3, and 1/4 of the sternum method by analyzing CT images. Results: When virtual tube thoracostomy routes were drawn at the mid-axillary line at the 5th ICS level, 150 patients (81.5%) on the right side and 179 patients (97.3%) on the left did not pass the diaphragm. However, at the lower 1/2 of the sternum level, 171 patients (92.9%, P<0.001) on the right and 182 patients (98.9%, P= 0.250) on the left did not pass the diaphragm. At the 5th ICS level, 129 patients (70.1%) on the right and 156 patients (84.8%) on the left were located in the safety zone and did not pass the diaphragm. Alternatively, at the lower 1/2, 1/3, and 1/4 of the sternum level, 139 (75.5%, P=0.185), 49 (26.6%, P<0.001), and 10 (5.4%, P<0.001), respectively, on the right, and 146 (79.3%, P=0.041), 69 (37.5%, P<0.001), and 16 (8.7%, P<0.001) on the left were located in the safety zone and did not pass the diaphragm. Compared to the conventional 5th ICS method, the sternum 1/2 method had a safety zone prediction sensitivity of 90.0% to 90.7%, and 97.3% to 100% sensitivity for not passing the diaphragm. Conclusions: Using the sternum length as a tube thoracostomy indicator might be feasible.

자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화 (Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer)

  • 박원;허승재;이정은
    • Radiation Oncology Journal
    • /
    • 제21권2호
    • /
    • pp.135-142
    • /
    • 2003
  • 목적: 자궁경부암으로 진단 받고 근치적 방사선치료를 받은 환자에서 방사선 치료 전과 치료 중 자기공명영상을 비교함으로써 삼차원입체조형치료나 강도변조방사선치료의 효과에 영향을 미칠 수 있는 자궁의 크기 및 위치 변화를 알아보았다. 대상 및 방법: 1997부터 2000년까지 삼성서울병원에서 자궁경부암으로 근치적 방사선치료를 시행 받은 환자 중 방사선치료 전과 치료 중간에 자기공명영상 촬영을 시행한 47명의 환자를 대상하였다. 방사선치료는 전골반조사와 강내조사가 시행되었는데 전골반조사는 골반 전체에 통상적 4문 조사법으로 매일 1.8 Gy씩, 주 5회 실시하며 총선량 50.4$\~$55.8 Gy (30.6$\~$45 Gy 이후에 골반중심부차폐) 조사하였고, 강내조사는 A점에 4 Gy씩, 매주 2회 시행하여 총선량 24 Gy까지 시행하였다. 자기공명영상 촬영은 방사선치료 시작 전과 치료 시작 후 3$\~$4주경 강내조사와 골반중심차폐를 하기 전에 실시되었다. 방사선치료 전과 치료 중 촬영된 자기공명영상의 T2 강조 시상면 영상과 축면 영상에서 자궁의 변화를 알기 위하여 자궁경관 크기, 자궁 크기, 자궁체부 크기, 자궁경관 굴곡각, 자궁체부 굴곡각, 과 자궁체부 회전각을 측정하였다. 결과: 자궁경관 크기는 치료 전에 평균 36.7 mm에서 치료 후 27.8 mm로 감소하였고, 자궁체부 크기는 평균 2.5 mm 감소하였으며, 자궁크기 차이는 평균 6.4 mm였다. 자궁경부에서 자궁저부까지의 거리 차이는 평균 15.2 mm였으며, 이 중 6예에선 30 mm 이상 크기가 줄었는데 이 경우에 종양의 크기가 모두 4 cm 이상이었다. 자궁경관 굴곡각은 평균 13.2$^{\circ}$, 자궁체부 굴곡각은 평균 16.9$^{\circ}$ 자궁체부 회전각은 평균 13.1$^{\circ}$ 차이가 있었다. 회전이나 굴곡 중 어느 하나라도 30$^{\circ}$이상 변화된 경우가 전체 환자 중 9예(19.1$\%$)가 있었다. 연령과 자궁경관 굴곡각의 차이는 통계적으로 유구한 연관이 있었고, 종양 크기에 따라 자궁경관 크기, 자궁 크기, 자궁체부 크기와 자궁경관 굴곡각은 모두 유의한 변화가 있었다. 그리고, 종양 크기가 4 cm 이상인 경우에 자궁경관의 크기, 자궁 크기와 자궁체부의 크기 변화가 모두 통계적으로 의미있는 차이를 보였다. 또한, 자궁경부로부터 자궁저부까지 거리 차이는 종양 크기가 4 cm 미만인 경우는 5.3 mm였으나 4 cm 이상일 때는 19.4 mm로 현저한 변화를 보였다. 자궁경관 굴곡각은 60세 미만인 경우 60세 이상보다 8$^{\circ}$ 정도 더 변화가 있었고, 종양 크기가 4 cm 이상일 때 미만일 때보다 2배 이상 굴곡 변화가 있었다. 결론: 자궁경부암 환자에서 근치적 방사선치료 시 치료에 따른 자궁 크기 및 위치 변화가 다양하고 개별적으로 예측하기 쉽지 않으므로, 특히, 60세 미만이거나 종양 크기가 4 cm 이상인 경우, 삼차원입체조형치료나 강도변조 방사선치료를 이용한 근치적 방사선치료 시 치료 중 개별환자의 계획용표적체적의 변화를 반드시 고려해야 한다고 생각한다.

무치악 환자를 위한 참고점들의 효용성에 대한 연구 (A study on the validity of reference points for edentulous patient)

  • 박정재;김명주
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.310-317
    • /
    • 2015
  • 목적: 한국 성인 유치악자를 대상으로 치아와 안모 사이의 크기 및 형태적인 상관관계, 구강 내 해부학적 기준점들과 치아배치 양상 사이의 관계를 조사하여 총의치 제작 시 무치악 환자 치료에 사용되는 기준점들의 효용성을 평가하고자 하였다. 대상 및 방법: 서울대학교 치의학 대학원생을 대상으로 상악 6전치가 정상적으로 배열되어 있는 성인 남성 270명 여성 280명을 선정하여 연구를 수행하였다. 악안면부의 해부학적 구조를 크게 변화시킬 수 있는 외과적 치료를 받은 경우, 교정치료를 받은 경우, 선천적으로 상악 전치부 치아 형태 및 수에 이상이 있는 경우, 상악 전치부 치관의 변형을 초래할 수 있는 수복치료를 받은 경우는 연구대상에서 제외하였다. 연구항목은 안모의 외형, 협골궁 폭경, 안모의 길이, 상악중절치의 형태 및 장경, 상악6전치의 치관 폭경, 견치간 거리, 절치유두 중심에서 중절치 순면까지의 거리, 절치유두 중심에서 양견치 첨단을 지나는 선까지의 수직거리이었다. 이를 바탕으로 안면계측항목과 모형계측항목간의 비율 및 상관관계를 통계적으로 분석하였다. 결과: 본 연구의 한계 내에서 다음과 같은 결과를 얻었다. 1) 안모의 외형과 상악 중절치의 형태가 일치하는 비율은 남성 55.56%, 여성 46.43%, 전체 50.91%이었다. 1) 협골궁 폭경과 상악중절치 폭경, 상악6전치 연합폭경의 비율은 각각 16.8 : 1, 3.0 : 1이며 통계적으로 양의 상관관계가 있었다. 2) 상모학상 안모의 길이(Trichion-Gnathion)와 상악중절치 치관 장경, 코뿌리점-턱끝융기점간 거리(Nasion-Gnathion)와 상악중절치 장경과의 비율은 각각 19.7 : 1, 11.6 : 1이었고 남성에서는 코뿌리점-턱끝융기점간 거리가, 여성에서는 안모의 길이가 더 큰 상관관계가 있었다. 3) 절치유두 중심과 양 견치첨단을 연결하는 선 사이의 수직거리는 $1.33{\pm}1.08mm$이었다. 4) 절치유두 중심에서 중절치 순면까지의 거리는 $9.23{\pm}1.20mm$이었다. 결론: 총의치 제작에 사용되는 기준점들은 한국 성인 유치악자의 경우에도 통계적으로 효용성을 가지며, 중요한 해부학적 지표가 임상적으로 의미를 가진다고 할 수 있다. 그러나 통계적으로 수치에서 차이를 보이고 개별적인 편차를 가지므로 인공치아의 선택이나 배열 후 환자의 동의를 받는 과정이 필수적이라고 할 수 있다.

Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사 (Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement)

  • 김원;김승미;김효정;송은영;이시호;오남식
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.175-184
    • /
    • 2011
  • Computer-guided system은 술 전에 임플란트 위치를 계획하고 이와 일치하도록 구강 내에 임플란트를 식립할 수 있게 하는 방법이다. 하지만 이렇게 임플란트를 식립한다 할지라도 실제 매식된 임플란트의 위치는 원래 계획하였던 위치와 차이가 있을 수 있다. 이 연구의 목적은 실제 임상에서 computer guided system을 이용하여 임플란트를 식립한 환자들의 경우 계획한 위치와 실제 식립된 임플란트 사이에 발생하는 변위량의 범위를 알아보고 그 임상적 적합성을 평가하는 것이다. 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)을 이용하여 Br${\aa}$nemark MK III Groovy RP (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)임플란트 식립을 시행 받은 다섯 명의 환자를 선정하였다. 수술용 형판에 지대주 유사체를 연결한 후 술 전 측정 모형을 제작하였고 최종 보철물 제작 시 최종 인상을 채득하여 술 후 측정 모형을 제작하였다. 두 측정 모형의 CT 방사선 사진을 촬영 후 3차원적으로 재현하였고 재현된 모델 상에서 식립된 임플란트 위치를 지정하였다. 각 임플란트는 임플란트 경부와 첨단의 중심점을 연결하여 임플란트 축을 설정하였으며 두 축 간의 각도가 측정되었다. 임플란트 간 거리는 각 임플란트의 경부에서, 설정된 임플란트 축이 지나가는 중심점 간의 거리를 측정하였다. 총 5명 환자의 58개 부위의 임플란트 간 술 전과 술 후 임플란트 거리와 각도 변위량이 기록되었으며 평균 및 최대 변위값을 산출하였다. 술 전과 술 후 임플란트 위치 간 거리의 변위량은 평균 0.41 mm였고 최대 1.7 mm의 범위 하에 있었다. 술 전과 술 후 임플란트 간 위치의 각도의 변위량은 평균 $1.99^{\circ}$를 나타냈으며 최대 각도 변위량은 $6.7^{\circ}$를 나타내었다. 술 전 계획된 임플란트와 술 후 식립된 임플란트 간의 길이와 각도에 따른 평균 변위량은 computer-guided implant system을 실제 임상에 적용하는 데 있어 큰 문제가 존재하지 않고 '수동적 적합(passive fit)'을 얻기에 무리가 없을 허용 가능할 만한 값을 나타냈다.