• 제목/요약/키워드: analysis for smoke control

검색결과 131건 처리시간 0.022초

제트 팬 설치 위치에 따른 직선터널 내의 제연해석 (Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel)

  • 변주석;임효재;강신형;이진호
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.662-668
    • /
    • 2007
  • In this study, jet fans are installed with 4 cases in the straight long tunnel; inlet-side setup, middle-side setup, outlet-side setup, and dispersion setup. A bus is selected as fired car, of which fire size is 20MW. And fired car locates at 100m, 700m, 1500m position from tunnel inlet, respectively. FLUENT, commercial finite-volume code, is used to analyze the performance. The velocity profile, $CO_2$ concentration, temperature distribution are examined for analysis. Performance of smoke control is compared by the backlayering length. Consequently, inlet-side setup of jet fans is a little more efficient than other cases considering the fire occurrence frequency in tunnel.

안전체험 시뮬레이터 개발에 관한 연구 (The study of Safety education, safe experience for students to develop research simulreyiteo)

  • 김태환
    • 한국재난정보학회 논문집
    • /
    • 제6권1호
    • /
    • pp.46-59
    • /
    • 2010
  • In this study, the safety training of comparative analysis of the realities of Korea's safety training and international experience and practical training for the safety experience of a virtual reality simulator, the development of safe conduct as a controlled motion simulator system, image H / W and the control system works, sound effects H / W and the control system works, 4D special effects (smoke, heat, wind, vibration) and a control system integration, mission control system for the selection and evaluation of the proposal, and safety training on Game S / W of development as we have never experienced an earthquake action plan and evacuate to escape the power of experience and the experience of an earthquake (vibration + video), Also the collapse and a fire escape on the experience of following second disaster, the building collapsed during an escape experience in the field, in case of fire According to the initial fire suppression and fire extinguisher usage experience - experience of smoke and heat to escape in, Moreover, the Daegu subway fire in public places such as subway and evacuated to escape the experience, considering the suggested Simulator.

지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구 (A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform)

  • 유지오;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제24권4호
    • /
    • pp.327-339
    • /
    • 2022
  • 본 연구에서는 지하철 승강장에서 열차화재가 발생하는 경우, 승강장 제연풍량 및 제연모드(급기 또는 배기)에 따른 정량적 위험도 평가를 통해 안전확보에 효과적인 제연풍량 및 모드를 제시함을 목적으로 한다. 이를 위해 중앙계단을 갖는 상대식 승강장을 모델로 하여 화재발생 시나리오를 작성하였으며, 시나리오별 화재해석을 수행하여 연기전파특성과 ASET을 비교·분석하고 대피해석을 수행하여 사망자수를 예측하였다. 또한, 시나리오별로 화재사고 발생률(F)/사망자수(N)선도(F/N선도)를 작성하여 제연풍량 및 제연모드에 따른 위험도를 비교·평가하였다. 소방시설 등의 성능위주 설계 방법 및 기준에서 정하는 유해요소(일산화탄소, 온도, 가시거리)에 대한 ASET 분석에서는 가시거리의 영향이 가장 크게 나타나고 있으며, 화재열차의 승강장 진입지연을 고려하지 않은 경우에 풍량을 4 × 833 m3/min할 때 ASET은 약 800초 정도로 분석되었다. 예상사망자수는 화재차량위치에 따라 큰 차이가 있으며, 계단부에 인접한 차량에서 화재가 발생하는 경우에 선두부 차량대비 3배 까지 증가하는 것으로 나타나고 있다. 또한 제연풍량이 증가하면 사망자수가 감소하며 배기 보다는 급기방식이 감소율이 증가한다. 급기풍량이 4 × 833 m3/min일 때 예상 사망자수는 제연을 수행하지 않는 경우 대비 13%수준으로 감소하는 것으로 나타났다. 위험도 평가결과, 제연을 수행하는 경우에는 현행 사회적 위험도 평가기준을 만족하는 것으로 나타나고 있으며, 예상사망자수는 제연을 수행하지 않는 경우, 10,000년에 29.9명에서 제연을 수행하는 경우에는 풍량이 4 × 833 m3/min일 때 4.36명으로 감소하는 것으로 분석되었다.

정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구 (A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment)

  • 이보훈;홍서희;백두산;이호형
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.539-552
    • /
    • 2022
  • 열차 정거장의 경우 연기배출이 제한된 지하공간이라는 특수성으로 인해 적절한 제연 설비가 갖추어지지 않는다면 화재 발생시 화재연기로 인한 피해가 확대될 우려가 있다. 이에 지하 정거장의 대피 안전성을 확보하기 위한 대책의 필요성이 부각되었으며, 화재시 승강장 이용객의 안전한 대피를 위한 연구가 국내외에서 지속적으로 수행되고 있다. 하지만 현재 열차 승강장에는 제연 경계벽과 PSD (Platform Screen Door)등에 의해 제연구역을 구획하여 제연설비를 설치하고 있으나, 화재시 제연구역별 제연방법(급기 또는 배기) 즉, 제연모드에 관한 기준은 제시되어 있지 않은 실정이다. 본 연구에서는 열차 정거장 화재시 제연모드에 따른 화재위험을 정량적으로 평가하기 위해서 화재해석 및 대피해석을 수행하여 사망자수를 추정하고 F/N선도를 도출하였으며, 이를 통해 최적 제연모드를 검토한 결과, 화재 구역 배기 및 인접구역 급기인 경우에 총 위험도가 가장 낮은 것으로 분석됐다.

난연성 폴리 올레핀 케이블 절연재료의 내화특성 (Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant)

  • 윤헌주;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

난연성 폴리 올레핀 케이블 절연재료의 내화특성 (Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant)

  • 윤헌주;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

대규모 실내경기장의 소방방재설비 적용현황 분석 (A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium)

  • 최동호;김춘동;양정훈;조영흠
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.135-145
    • /
    • 2010
  • 본 논문은 사례조사를 통해 국내외 대규모 실내경기장의 소방방재계획상의 특정을 분석함으로서 향후 국내에 건립될 대공간 건축물의 소방방재계획 수립에 활용될 기초자료를 도출코자 하였다. 본 논문에서는 국내의 소방방재설비관련 법규 검토와 국내 3개, 국외 8개의 대규모 실내경기장을 대상으로 화재감지설비 소화설비 배연설비 피난계획 적용현황을 조사하여 대공간의 소방방재시스템의 동향을 파악하고 이들을 비교, 분석하였다. 연구 결과 대규모 실내경기장의 화재감지설비는 공간특성에 적합한 적외선화재감지기, 염감지기 등이 유력한 화재감지설비로 사용되며, 소화설비는 건식살수설비, 방수총소화설비 등이 채택되었으며 배연에서는 축연시스템이 적극 활용됨을 확인하였다.

  • PDF

환기 및 소방용 복합댐퍼의 설계인자에 관한 연구 (A Study on the Design Factors of Complex Damper for Ventilation and Fire Protection)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.42-47
    • /
    • 2011
  • 본 연구에서는 환기 및 소방용 복합댐퍼의 개발을 위한 기초 연구의 일환으로 복합댐퍼의 설계인자에 관한 연구를 수행하였다. 본 연구는 복합댐퍼의 프로세스와 운동 메커니즘, 기구 모델링을 바탕으로 복합댐퍼의 설계 및 해석이론을 제시하였고, 설계 및 해석이론을 바탕으로 한 운동해석 시뮬레이션을 통해 복합댐퍼의 각 요소를 설계할 수 있는 엔지니어링 데이터 구축과 원천기술을 확립하였다. 따라서 본 연구를 통해 환기 및 소방용 복합댐퍼 개발에 폭넓게 응용할 수 있는 결과를 얻었다. 본 연구를 바탕으로 복합댐퍼가 개발되면 환기풍도로부터 유입되는 연기제어와 기술적 대책을 마련할 수 있을 것으로 본다.

중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성 (Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel)

  • 백두산;이승철
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.9-17
    • /
    • 2016
  • 중규모 도로터널의 경우 제연설비 설치가 의무화 되어있지 않기 때문에 화재가 발생할 경우 이용객들이 많은 피해를 입을 수 있다. 따라서 본 연구에서는 연장 1,000 m 2차로 일방통행방식의 도로터널을 대상으로 3차원 수치해석, 정량적 위험도 평가를 통해 제연경계벽이 설치되지 않을 때와 설치간격이 100, 150, 200, 250 m일 때 화재에 의하여 발생되는 연기류 등이 시간에 따른 확산을 분석하였다. 그 결과 중규모 도로터널에 제연경계벽을 설치할 경우 설치하지 않은 경우보다 화재로부터 발생되는 고온의 공기와 독성가스의 확산이 지연되는 것을 확인할 수 있었다. 또한 수치해석 대상 중에서 제연경계벽의 설치간격이 100 m인 경우 화재로 인해 발생된 고온의 공기와 독성가스의 확산이 다른 경우보다 많이 지연되어 터널 이용객이 피난하는데 가장 적합한 것으로 나타났다.