• Title/Summary/Keyword: amplitude difference

Search Result 652, Processing Time 0.024 seconds

Nonlinear Analysis on Dynamic Behavior of a Rotor-Bearing System Under External Disturbances (외란을 받는 축-베어링 시스템의 동적 거동에 대한 비선형 해석)

  • 노병후;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.334-339
    • /
    • 2001
  • The nonlinear vibration characteristics of hydrodynamic journal bearings with a circumferentially groove are analyzed numerically when the external sinusoidal disturbances are given to the rotor-bearing system continuously. Also, the cavitation algorithm implementing the Jakobsson-Floberg-Olsson boundary condition is adopted to predict cavitation regions in the fluid film more accurately than conventional analysis which uses the Reynolds condition. It is found that the difference between linear and nonlinear analysis is much more remarkable as the amplitude of external disturbance increases, and it depends upon the excitation frequency of external disturbance. It is also shown that the cavity region in the fluid film is increased as the amplitude or excitation frequency of external disturbance increases. The whirling center of the steady state orbit moves closer to the bearing center as the amplitude or the excitation frequency of the external disturbance increases because of smaller range of full film region.

  • PDF

Geometric Effects on Pressure Distribution in Mechanical Face Seals (기계평면시일의 기하학적 형태가 압력분포에 미치는 영향에 관한 연구)

  • 김청균;이일권
    • Tribology and Lubricants
    • /
    • v.5 no.2
    • /
    • pp.48-54
    • /
    • 1989
  • The effects of angular misalignment, coning and the temperature difference between the primary seal ring and the seal seat on the pressure distribution in mechanical face seals are analyzed. The modified Reynolds equation for the temperature dependent viscosity was solved by a finite difference approximation and Gauss-Seidel method. It is shown that the amplitude of pressure is significantly affected by the misalignment of the seals and a large temperature difference between the rotor and the stator.

Effects of stimulus similarity on P300 amplitude in P300-based concealed information test (P300-기반 숨긴정보검사에서 자극유사성이 P300의 진폭에 미치는 영향)

  • Eom, Jin-Sup;Han, Yu-Hwa;Sohn, Jin-Hun;Park, Kwang-Bai
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.541-550
    • /
    • 2010
  • The present study examined whether the physical similarity of test stimuli affects P300 amplitude and detection accuracy for the P300-based concealed information test (P300 CIT). As the participant pretended suffering from memory impairment by an accident, own name was used as a concealed information to be probed by the P300 CIT in which the participant discriminated between a target and other (probe, irrelevant) stimuli. One group of participants was tested in the easy task condition with low physical similarity among stimuli, the other group was tested in the difficult task condition with high physical similarity among stimuli. Using the base-to-peak P300 amplitude, the interaction effect of task difficulty and stimulus type was significant at $\alpha$=.1 level (p=.052). In the easy task condition the difference of P300 amplitude between the probe and the irrelevant stimuli was significant, while in the difficult task condition the difference was not significant. Using peak-to-peak P300 amplitude, on the other hand, the interaction effect of task difficulty and stimulus type was not significant with significant differences of P300 amplitude between the probe and the irrelevant stimuli in both task difficulty conditions. The difference of detection accuracy between task conditions was not significant with both measures of P300 amplitude although the difference was much smaller when peak-to-peak P300 amplitude was used. The results suggest that the efficiency of P300 CIT would not decrease even when the perceptual similarity among test stimuli is high.

  • PDF

F-Wave Analysis in Patients with Clinically Diagnosed Carpal Tunnel Syndrome (임상적으로 진단된 수근관증후군 환자에서 F파 분석)

  • Kim, Seong-Hee;Yoo, Bong-Goo;Kim, Kwangsoo;Yoo, Kyung-Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.2
    • /
    • pp.108-113
    • /
    • 2002
  • Background and Objective : Carpal tunnel syndrome (CTS) is the most common mononeuropathy encountered in clinical practice. No single procedure or group of procedures has demonstrated adequate sensitivity. F-wave study in CTS is very rarely reported. To determine the diagnostic usefulness of new parameters of F-wave and comparative study of F-wave parameters of median and ulnar nerves in patients with CTS. Methods : F-wave responses of median and ulnar nerves were analyzed from 27 patients with clinically diagnosed CTS and 22 age and gender-matched normal control. Conventional F-wave parameters were studied. Also, the usefulness of new parameters such as mean and maximal ulnar-median F-wave latency differences, ulnar-median F-wave persistence and chronodispersion differences, median/ulnar F-wave amplitude ratio, and F-wave conduction velocity (FCV) using mean and maximal latency were assessed. Results : Compared with controls, median F-wave minimal, maximal and mean latencies, mean F-wave amplitude/M-wave amplitude, minimal, mean and maximal ulnar-median F-wave latency differences, and FCVs using minimal, maximal and mean latency were significant (P<0.05~0.001). Median F-wave minimal, maximal and mean latencies, mean ulnar-median F-wave latency difference, and FCVs using minimal, maximal and mean latency showed high sensitivity and specificity. Mean ulnar-median F-wave latency difference and FCVs using maximal and mean latency were new parameters. Conclusion : New F-wave parameter including mean ulnar- median F-wave latency difference and FCVs using maximal and mean latency may be a useful to assess the CTS. Also, median F-wave minimal, maximal and mean latencies, and FCV using minimal latency may be included in routine diagnostic tests in CTS.

  • PDF

The Phase Difference Measurement Module Development for Amplitude Modulated Range Measurement System (진폭 변조 거리 측정 시스템을 위한 정밀 위상차 측정부 개발)

  • Noh, Hyoung-Woo;Park, Jeong-Ho;Kang, Il-Heung;Choi, Mun-Gak;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • A amplitude modulation(AM) range measuring system utilizes the phase difference of the modulated envelope of the reflected signal to measure the distance. It is known that the AM system has a problem in accuracy due to antenna leakage signals and spurious reflection signals, but an AM range measurement system using an active reflector, which shifts the frequency bands, has been proposed in order to minimize the measurement errors due to spurious signals. In this paper, a new phase measurement module for the AM range measurement system, which enables to measure long distance with good accuracy, is proposed. The modulation frequency is alternatively selected between 8 and 1 MHz, and the measured distance range with this module is up to 150 m within 2 cm accuracy. A JK flip-flop circuit is used for higher phase accuracy, and an XOR circuit is used to cover long distance.

Effects of Tropospheric Mapping Functions on GPS Data Processing

  • Won, Ji-Hye;Park, Kwan-Dong;Ha, Ji-Hyun;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.21-30
    • /
    • 2010
  • In processing space geodetic data, mapping functions are used to convert the tropospheric signal delay along the zenith direction to the line of sight direction. In this study, we compared three mapping functions by evaluating their effects on the tropospheric signal delay and position estimates in GPS data processing. The three mapping functions tested are Niell Mapping Function (NMF), Vienna Mapping Function 1 (VMF1), and Global Mapping Function (GMF). The tropospheric delay and height estimates from VMF1 and GMF are compared with the ones obtained with NMF. The differences among mapping functions show annual signals with the maximum occurring in February or August. To quantitatively estimate the discrepancies among mapping functions, we calculated the maximum difference and the amplitude using a curve fitting technique. Both the maximum difference and amplitude have high correlations with the latitude of the site. Also, the smallest difference was found around $30^{\circ}N$ and the amplitudes increase toward higher latitudes. In the height estimates, the choice of mapping function did not significantly affect the vertical velocity estimate, and the precision of height estimates was improved at most of the sites when VMF1 or GMF was used instead of NMF.

Electromyography Activity of Lower Leg Muscles After Ankle Sprain (발목 관절 염좌 후 하퇴근 근활성도의 특성)

  • Ha, Sung-Hee;Lee, Hyun-Ok;Kim, Suhn-Yeop;Kim, Jong-Soon
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.621-631
    • /
    • 2005
  • The purpose of this study was to measure magnitude of lower leg muscle activity during dynamic stability tests performed on an unstable board by subjects with sprained lateral ankles. Fifteen lateral ankle sprain subjects(8 male, 7 female) participated in this study. The muscle activity was measured at gastrocnemious, tibialis anterior, peroneus longus during dynamic stability tests performed on Biodex stability system as surface EMG. The EMG amplitude of each muscle was normalized to the amplitude in the maximal voluntary isometric contraction(MVIC) of each muscle. As results, peroneus longus evidenced significant difference at stable and unstable grade comparing injured with uninjured sides. Gastrocnemious and tibialis anterior evidenced no significant difference. Change of muscle activity with stable and unstable grade evidenced no significant difference on injured and uninjured sides. The data provided information on peroneus longus contributes to dynamic stability after lateral ankle sprains. Peroneus longus training program may have to be emphasized after an ankle sprain.

  • PDF

Modification of Retinal Function by Hypothermia and Hyperthermia

  • Chon, Young-Shin;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.7 no.4
    • /
    • pp.161-167
    • /
    • 2000
  • Temperature-dependent electroretinogram responses were investigated in the dark adapted bullfrog eyes within the physiological temperature range 0-40$\^{C}$. In hypothermic process(25→0→25$\^{C}$), the amplitude of b-and c-wave decreased with lowering the temperature again. Both b-wave amplitude and threshold responses were maximal around 15$\^{C}$ during the temperature increment. Upon warming to room temperature again (25$\^{C}$), the b-wave amplitude was approximately doubled as compared to that of control without temperature changes. During the hyperthermic process (25→40→25$\^{C}$), however, the responses decreased with warming, and the wave amplitude failed to recover by cooling to 25$\^{C}$ again. As describe above, the recoveries of ERG in both processes show the striking difference. The hypothermia induces the amplification of the b-wave, that is, enhances the retinal function with the temperature recovery toward room temperature. While the hypertherima produces the decrease of the b-wave even though recovered to room temperature, which indicates an irreversible retina. The morphological alteration is shown both hypothermic and hyperthermic process, such as an appearance of large vacuoles and degenerating outer segments, more intense in hyperthermia, similar to light induced damage.

  • PDF

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

Mapping of the lost riprap in shallow marine sediments using SBP (SBP를 이용한 해저 천부에 유실된 사석의 조사)

  • Shin, Sung-Ryul;Kim, Chan-Su;Yeo, Eun-Min;Kim, Young-Jun;Ha, Hee-Sang
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.220-221
    • /
    • 2005
  • Sub-bottom profiler(SBP) has been used extensively for the mapping of basement in the foundation design of offshore structure, for pre- and post-dredging operations within harbors and channels, for selection of pipeline routes, sitting of drilling platforms, and in the exploration for an aggregates such as sands and gravels. During the construction of Siwha embankment for irrigation water and the expansion of arable land, the breaking of an embankment unfortunately occurred so that a lot of riprap was swept away and widely dispersed by the tide and strong current. The feasibility study for the construction of the tidal-powered electric plant in Siwha embankment was performed quite recently. Therefore we made use of SBP survey to investigate the distribution of the lost riprap. We could successfully map out the distribution of the lost riprap from the reflection amplitude characteristics of the sediments in SBP data set. We demonstrated the variation of reflection amplitude versus the sediments with and/or without riprap by means of the numerical modeling of acoustic wave equation using finite difference method. Also we examined an amplitude anomaly of the ripraped area through the physical modeling using ultrasonic.

  • PDF