• Title/Summary/Keyword: ammonia solution

Search Result 365, Processing Time 0.03 seconds

Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators (암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석)

  • Ji, Je-Hwan;Jeong, Eun-Soo;Jeong, Si-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

Continuous Decomposition of Ammonia by a Multi Cell-Stacked Electrolyzer with a Self-pH Adjustment Function (자체 pH 조정 기능을 갖는 다단 전해조에 의한 암모니아의 연속식 분해)

  • Kim, Kwang-Wook;Kim, Young-Jun;Kim, In-Tae;Park, Geun-Il;Lee, Eil-Hee
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • This work has studied the changes of pH in both of anodic and cathodic chambers of a divided cell due to the electrolytic split of water during the ammonia decomposition to nitrogen, and has studied the continuous decomposition characteristics of ammonia in a multi-cell stacked electrolyzer. The electrolytic decomposition of ammonia was much affected by the change of pH of ammonia solution which was caused by the water split reactions. The water split reaction occurred at pH of less than 8 in the anodic chamber with producing proton ions, and occurred at pH of more than 11 in the cathodic chamber with producing hydroxyl ions. The pH of the anodic chamber using an anion exchange membrane was sustained to be higher than that using a cation exchange membrane, which resulted in the higher decomposition of ammonia in the anodic chamber. By using the electrolytic characteristics of the divided cell, a continuous electrolyzer with a self-pH adjustment function was newly devised, where a portion of the ammonia solution from a pHadjustment tank was circulated through the cathodic chambers of the electrolyzer. It enhanced the pH of the ammonia solution fed from the pH-adjustment tank into the anodic chambers of the electrolyzer, which caused a higher decomposition yield of ammonia. And then, based on the electrolyzer, a salt-free ammonia decomposition process was suggested. In that process, ammonia solution could be continuously decomposed into the environmentally-harmless nitrogen gas up to 83%, when chloride ion was added into the ammonia solution.

Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane (관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성)

  • Ahn, Yong-Tae;Hwang, Yu-Hoon;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.353-358
    • /
    • 2011
  • In this study, ammonia removal characteristics in membrane contactor system under various operating conditions were evaluated. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with the tubular PTFE membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on ammonia removal mechanism. Overall ammonia removal rate was not significantly affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of strip solution. Membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

Analysis of Falling-film Generator in Ammonia-water Absorption System (암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석)

  • 김병주;손병후;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

Release of Ammonia Odor from AAFA (Ammonia Adsorbed Fly Ash) by Installation of NOx Reduction System

  • Kim, Jae-kwan;Park, Seok-un;Lee, Hyun-dong;Chi, Jun-wha
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.437-445
    • /
    • 2016
  • This paper discussed the effect of ammonia concentration adsorbed on fly ash for the ammonia emission as AAFA (Ammonia Adsorbed Fly Ash) produced from coal fired plants due to operation of NOx reduction technologies was landfilled with distilled or sea water at closed and open systems, respectively. Ammonia bisulfate and sulfates adsorbed on fly ash is highly water soluble. The pH of ammonium bisulfate and sulfate solution had significant effect on ammonia odor emission. The effect of temperature on ammonia odor emission from mixture was less than pH, the rate of ammonia emission increased with increased temperature when the pH conditions were kept at constant. Since AAFA increases the pH of solution substantially, $NH_3$ in the ash can release the ammonia order unless it is present at low concentration. $NH_4{^+}$ ion is unstable in fly ash and water mixtures of high pH at open system, which is changed to nitrite or nitrate and then released as ammonia gas. The proper conditions for < 20 ppm of ammonia concentration released from the AAFAs landfilled in ash pond were explored using an open system with sea water. It was therefore proposed that optimal operation to collect AAFA of less than 168 ppm ammonia at the electrostatic precipitator were controlled to ammonia slip with less than 5 ppm at SCR/SNCR installations, and, ammonia odor released from mixture of fly ash of 168 ppm ammonia with sea water under open system has about 20 ppm.

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

Mass transfer in adiabatic rectifier of ammonia-water absorption system (암모니아-물 흡수식 시스템에서 단열정류기의 물질 전달)

  • 김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.414-421
    • /
    • 1999
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and liquid interface. In the present work, the adiabatic rectification process of ammonia-water vapor on the vertical plate was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer in each phases were investigated. The stripping of water in vapor mixture occurred new the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer in falling film.

  • PDF

The Geochemical Interpretation of Phase Transform and Fe-leaching Efficiency for Pyrite by Microwave Energy and Ammonia Solution (마이크로웨이브 에너지에 의한 황철석의 상변환과 암모니아 용액에 의한 Fe-용출 효율에 관한 지구화학적 해석)

  • Kim, Bong-Ju;Cho, Kang-Hee;Choi, Nag-Choul;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.139-150
    • /
    • 2013
  • In order to effectively leach Fe from pyrite, the application of microwave energy and ammonia solution has been conducted. Pyrite transforms into hematite and pyrrhotite when treated with microwave radiation for 60 minutes, and in this time the highest amount of Fe was leached by the ammonia solution. Up to 99% of the Fe was leached when the experimental conditions were: 325-400 mesh particle size for the pyrite and 60 min. was the microwave exposure time. The ammonia leaching conditions were 0.3 M sulfuric acid, 2.0 M ammonium sulfate and 0.1 M hydrogen peroxide concentration. The pyrite, hematite, and pyrrhotite were not detected using XRD analysis from the solid-residues treated by the ammonia solution except for quartz.

Estimation of Residual Biomass, PHB, and Nutrient Concentrations by Supplied Amount of Ammonia Solution in Fermentation of Alcaligenes latus

  • Lee, Yong-Woo;Tsuneo Yamane
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.5
    • /
    • pp.554-561
    • /
    • 1999
  • A novel estimation method was investigated for determining the concentrations of residual biomass, poly-3-hydroxybutyrate (PHB), and main nutrients including carbon and nitrogen sources, phosphate, and mineral ions from the supplied amount of ammonia solution used for a pH-control solution and nitrogen source in a PHB fermentation. The estimation equations for a batch culture and a fed-batch culture were derived from the relationship between the growth rate of residual biomass and the feed rate of the pH-control solution, and then were applied to the batch culture and the fed-batch cultures of Alcaligenes latus. This method was successfully applied to estimate the concentrations of residual biomass, PHB, and nutrients.

  • PDF

Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas (고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가)

  • Bae, Byung-Uk;Choi, Ki-Seung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.