확산형 흡수식 냉장고의 사이클 해석 (Cycle Analysis of Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

대두(大豆)에 대한 Ammonia 가스의 영향 (Effects of ammonia gas on soybean plant)

  • 김복영;한기학;김선관
    • 한국토양비료학회지
    • /
    • 제12권2호
    • /
    • pp.109-116
    • /
    • 1979
  • Ammonia 가스를 $0.15mg/{\ell}$, $0.25mg/{\ell}$, $0.5mg/{\ell}$로 대두(大豆)의 영양생장기에 각(各) 1시간(時間)씩 접촉(接觸)시켰고, $0.2mg/{\ell}$의 Ammonia 가스를 1일중시각별(日中時刻別)로 06:00-07:00, 10:00-11:00, 14:00-15:00, 18:00-19:00, 22:00-23:00시(時)에 각각(各各) 1시간(時間)씩 접촉(接觸)시켜 대두(大豆)의 수량(收量), 피해증상, 피해엽율(被害葉率), 체내질소 및 엽록소 함량(含量)을 조사(調査)한 결과(結果)는 다음과 같다. 가. Ammonia 가스농도(濃度)가 증가함에 따라서 유의성(有意性)있는 피해엽율(被害葉率) 및 감수율증가를 가져왔고, 주간(晝間)에 접촉(接觸)한 것이 야간(夜間)에 접촉(接觸)한 것보다 감수(減收)가 컸다. 나. 피해엽율(被害葉率)과 수량간(收量間)에는 고도(高度)의 유의성(有意性) 있는 부(否)의 상관($r=-0.9553^{**}$)이 있었다. 다. $0.2mg/{\ell}$의 Ammonia 가스는 14:00-15:00시(時)에 접촉(接觸)한 것이 피해엽율(被害葉率)이 가장 컸으며 22:00~23:00시에 접촉(接觸)한 것이 가장 적었다. 라. Ammonia 가스농도증가에 따라 식물체내 전질소(全窒素) 및 수용성질소함량(水溶性窒素含量)은 증가하는 경향(傾向)이고 엽록소함량은 감소(減少)하는 경향(傾向)이었으며 엽록소 a는 b보다 감소정도(減少程度)가 컸다. 마. 체내질소함량은 오후(午後)에 접촉(接觸)한 것이 오전(午前)에 접촉(接觸)한 것보다 많았으며 엽록함량은 야간(夜間)에 접촉(接觸)한 것이 주간(晝間)에 접촉(接觸)한 것보다 많았다. 바. 엽록체의 Spectra는 10~11시(時)에 가장 감소(減少)가 컸고 22~23시(時)에 가장 감소(減少)가 적었다.

  • PDF

고농도 암모니아를 함유한 전자 폐수의 암모니아 탈기 실증 연구 (Demonstration Study on Ammonia Stripping in Electronic Industry Wastewater with High Concentrations of Ammonia Nitrogen)

  • 손재현;김영희
    • 청정기술
    • /
    • 제29권4호
    • /
    • pp.297-304
    • /
    • 2023
  • 첨단 전자 제품 산업의 비약적인 발전은 환경적 측면에서 고농도 암모니아 폐수의 증가를 초래했다. 고농도 암모니아 폐수를 안정적으로 처리하기 위해 다양한 방법의 기술이 시도되고 있으나, 지금까지 성공적인 기술이 개발되어 적용되지는 못하고 있다. 본 연구에서는 첨단 전자산업에서 발생하는 고농도 암모니아 함유 폐수에 대하여 밀폐(closed) 순환형 대향류 충전탑 형식의 실증설비를 이용하여 온도, 공기부하율 그리고 폐수부하율 변화에 따른 암모니아성 질소의 제거효율과 제거 특성을 평가하였다. 폐수량 20.8 m3 h-1, 공기량 18,000 Nm3 h-1의 운전 조건에서 온도를 45, 50, 55 그리고 60℃로 변경하여 운전한 결과, 암모니아성 질소(NH3-N)의 제거율은 각각 87.5, 93.4, 96.8 및 98.7%로 온도가 제거율에 미치는 가장 큰 영향 인자임을 알 수 있었다. 공기부하율을 증가시키면 제거율도 증가하나, 흡수탑의 액적(droplet)이 탈기탑으로 유입되어 제거율 증가는 크지 않았다. 폐수 부하율이 변경되어도 제거율은 크게 변하지 않았는데, 이는 제거율에 영향이 없는 것이 아니라, 상대적으로 높은 공기부하율에 기인한 것으로 판단된다. 실증연구를 통해 암모니아 탈기법은 첨단 전자산업에서 발생하는 고농도 암모니아 폐수를 안정적으로 처리할 수 있는 적정한 공법임을 확인할 수 있었다.

Paramecium bursaria와 공생하는 Chlorella와 Chlorella ellipsoidea의 질소대사에 관한 비교연구 (A Comparative Study on the Nitrogen Metabolism of Symbiotic Chlorella from Paramecium bursaria with Chlorella ellipsoidea)

  • 장남기
    • Journal of Plant Biology
    • /
    • 제29권3호
    • /
    • pp.145-156
    • /
    • 1986
  • The excretion of ammonia and glutamine synthetase activities were measured in aposymbiotic Paramecium and symbiotic Paramecium. The uptake of nitrate and ammonia, and specific enzyme activities of nitrate reductase, glutamate dehydrogenase and glutamine synthetase were investigated in symbiotic Chlorella from Paramecium bursaria and Chlorella ellipsoidea. The ammonia concentration in the culture media of aposymbiotic Paramecium was increased according to the growth of the Paramecium but it was not changed in symbiotic Paramecium. Nitrate, the major nitrogen source, was taken up at a rate of 0.635 nmol/ 106 Chlorella/hr in Chlorella ellipsoidea. Most of ammonia was assimilated to glutamine by glutamine synthetase, of which acitivty was 1,467 $\mu$mol/mg protein/min in Chlorella elliposidea. Contrary to Chlorella ellipsoidea, ammonia and glutamine transported from the Paramecium were the nitrogen source of symbiotic Chlorella and ammonia was taken up at a rate of 3.854 nmo./106 Chlorella/hr into synmbiotic Chlorella. Most of ammonia were assimilated to glutamate by glutamate dehydrogenase in symbiotic Chlorella. The glutamate dehydrogenase (GDH/NADH) activity was 0.851 $\mu$mol/mg protein/min.

  • PDF

식품 폐수 처리 시설에서 암모니아성 악취제거 세균의 분리 및 특성 분석 (Isolation and Characterization of Ammonia-removing Bacteria from a Food-wastewater Treatment Facility)

  • 오경희;최인학;조영철
    • 대한환경공학회지
    • /
    • 제30권6호
    • /
    • pp.653-658
    • /
    • 2008
  • RABC 처리 공정을 사용하여 고농도 식품폐수를 처리할 때 악취가 적게 발생하는 기작을 밝히기 위하여, RABC 공정으로 부터 암모니아성 악취의 제거능이 우수한 세균을 분리하고 이의 특성 및 제거능을 평가하였다. 분리된 암모니아 제거 세균 중 제거능이 뛰어난 것으로 밝혀진 5종의 세균은 각각 Citrobacter, Enterobacter, Buttiauxella, Shigella, Aeromonas 속에 속하는 세균과 분류학적으로 가장 근접하였으며, 이들 세균은 모두 동물의 내장에서 발견된 것이다. 따라서 본 연구에서 분리된 세균은 폐수 처리시설에 유입된 돼지의 도축 부산물에서 유래한 것으로 판단된다. 암모니아 제거과정에서 아질산염 또는 질산염이 발생하지 않는 것으로 보아, 분리된 세균은 암모니아 동화과정을 통해 폐수 중 암모니아의 농도를 저감시키는 것으로 판단된다. 분리된 세균의 암모니아 제거능이 매우 뛰어난 것으로 측정되었으며, 이러한 결과로 판단할 때 이들이 RABC 폐수 처리 공정의 악취 제거에 중요한 기여를 하고 있는 것으로 보인다.

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

질화세균을 고정화한 충전층 생물반응기에서 저농도 암모니아성 질소 제거 (Removal of Low Concentration Ammonia Nitrogen using a Packed Bed Bioreactor Immobilized with Nitrifier Consortium)

  • 이창근;김병진;이민수;김용하;서근학
    • 청정기술
    • /
    • 제13권1호
    • /
    • pp.16-21
    • /
    • 2007
  • 본 실험은 질화세균을 고정화한 충전층 생물반응기에서 저농도 암모니아성 질소(total ammonia nitrogen, TAN)의 제거 시 수력학적 체류시간(hydraulic residence time, HRT), 유입수 암모니아성 질소농도 및 온도에 의한 영향을 평가하였다. 수력학적 체류시간이 감소함에 따라 암모니아성 질소의 제거속도는 증가하였고, 암모니아성 질소의 제거 시 최적 수력학적 체류시간은 0.2시간이었다. 수력학적 체류시간이 0.2시간에서 암모니아성 질소의 제거속도는 $226.1\;g/m^3{\cdot}day$, 제거효율은 88.8%을 나타내었다. 유입수 암모니아성 질소 농도가 증가함에 따라 암모니아성 질소의 제거속도는 증가하였다. 온도 $20{\sim}35^{\circ}C$에서 암모니아성 질소의 제거속도와 제거효율은 일정하게 유지했다.

  • PDF

암모니아 탈기공정을 이용한 침출수의 암모니아성 질소제거(I) (Removal of Ammonia-Nitrogen Contained in Landfill Leachate by Ammonia Stripping(I))

  • 이병진;조순행
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1893-1904
    • /
    • 2000
  • 질소제거를 위한 처리기술은 아직까지는 주로 생물학적인 처리기술에 의존하고 있는 실정이다. 그러나 생물학적인 처리기술은 하수 등과 같은 저농도 암모니아성 질소성분을 함유한 폐수에 대해서는 비교적 광범위하게 정립되어 있는 반면, 질소성분외에 난분해성 및 독성물질을 고농도로 함유하고 있는 침출수 및 산업폐수에 생물학적 처리기술을 적용하는 방법은 처리효율면에서 한계가 있다. 따라서 본 연구에서는 질소 처리기술이 비교적 정립되어 있지 않은 고농도의 암모니아성 질소 성분을 함유한 침출수를 대상으로 생물학적 처리공정의 이전에 질소제거를 위한 암모니아 탈기공정의 적용가능성을 타진하고 자원 재활용 측면을 고려하여 처리된 질소성분의 회수 가능성을 조사하는 데 목적을 두었다. 실험결과 암모니아 탈기공정을 위하여 pH를 조정하기 위해서는 NaOH보다 $Ca(OH)_2$를 사용하는 것이 적정한 것으로 조사되었다. 암모니아 탈기에 적정한 pH는 10.5로 조사되었으며, 목표치인 500 mg/L를 만족시키기 위하여 소요되는 반응시간은 $35^{\circ}C$, 10 L/L/min의 조건에서는 2시간, $55^{\circ}C$, 10.0 L/L/min의 조건에서는 1시간이 소요되는 것으로 조사되었다. 이에 따라 생물학적 처리공정의 전단에 air diffused system을 이용한 암모니아 탈기공정의 적용은 고농도의 암모니아성 질소를 함유한 침출수의 처리에 매우 효과적인 것으로 결론지울 수 있었다. 그러나 생물학적 처리공정인 MLE 공정(T-N 최대 제거율: 78%, 암모니아성 질소 제거율: 98~99%)과 혐기성 소화조, 폭기식 라군산화조에서 질소성분을 완전히 제거하기 위하여 이들 공정전에 적용한 암모니아 탈기공정의 운전에 소요되는 약품비를 각각 산출하여 비교한 결과 암모니아 탈기공정이 MLE 공정에 비해 약품 소모비가 약 16% 정도 더 많이 소요되는 것으로 조사되었으므로 암모니아 탈기공정의 경제성을 높이기 위하여 슬러지를 재이용하는 방안 등을 검토하여야 할 것으로 판단되었다.

  • PDF

암모니아수 흡수제를 이용한 이산화탄소 제거 공정에서 침전생성이 조업영역에 미치는 영향 (Effect of Precipitation on Operation Range of the CO2 Capture Process using Ammonia Water Absorbent)

  • 유정균;박호석;홍원희;박종기;김종남
    • Korean Chemical Engineering Research
    • /
    • 제45권3호
    • /
    • pp.258-263
    • /
    • 2007
  • 배가스 이산화탄소 처리를 위한 화학적 흡수공정의 새로운 흡수제로서 암모니아수의 적용 가능성을 고찰하였다. 이산화탄소 흡수용량과 침전 발생의 관점에서 적합한 암모니아수 흡수제 농도와 $CO_2$ 부하(loading, $molCO_2/molNH_3$)를 결정하였다. 이를 위하여 전해액에 대한 Pitzer 모델을 이용하여 암모니아 흡수제 농도에 따른 흡수용량과 침전 발생여부를 계산하였다. $5\;molNH_3/kgH_2O$ 이상의 암모니아수 흡수제를 사용하여 기존 아민류 흡수제 이상의 흡수용량은 얻을 수 있었다. 각 암모니아 흡수제 농도에서 $NH_4HCO_3$ 침전의 발생으로 인하여 조업이 제약되는 $CO_2$ 부하를 구하였다. $5{\sim}14\;molNH_3/kgH_2O$의 암모니아 흡수제는 293, 313 K에서 $CO_2$ 부하 0.5 이상에서 침전이 발행하였다. 침전 생성 $CO_2$ 부하값 이하로 흡수탑을 조업함으로써 고농도 암모니아 흡수제가 배가스 $CO_2$ 처리 공정에 사용될 수 있음을 알 수 있었다. 흡수용량과 침전발생을 고려하여 배가스 이산화탄소 처리를 위한 흡수제 최적온도는 암모니아수 농도에 따라 297~312 K이었다.

Analysis of Free Ammonia Inhibition of Nitrite Oxidizing Bacteria Using a Dissolved Oxygen Respirometer

  • Kim, Dong-Jin;Lee, Dong-Ig;Cha, Gi-Cheol;Keller, Jurg
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.125-130
    • /
    • 2008
  • Free ammonia ($NH_3$-N) inhibition of nitrite-oxidizing bacteria (NOB) has been widely studied for partial nitrification (or nitrite accumulation) and denitrification via nitrite ($NO_2^-$-N) as a low-cost treatment of ammonium containing wastewater. The literature on $NH_3$-N inhibition of NOB, however, shows disagreement about the threshold $NH_3$-N concentration and its degree of inhibition. In order to clarify the confusion, a simple and cheap respirometric method was devised to investigate the effect of free ammonia inhibition of NOB. Sludge samples from an autotrophic nitrifying reactor were exposed to various $NH_3$-N concentrations to measure the maximum specific nitrite oxidation rate ($\hat{K}_{NO}$) using a respirometer. NOB biomass was estimated from the yield values in the literature. Free ammonia inhibition of nitrite oxidizing bacteria was reversible and the specific nitrite oxidation rate ($K_{NO}$) decreased from 0.141 to 0.116, 0.100, 0.097 and 0.081 mg $NO_2^-$-N/mg NOB h, respectively, as the $NH_3$-N concentration increased from 0.0 to 1.0, 4.1, 9.7 and 22.9 mg/L. A nonlinear regression based on the noncompetitive inhibition mode gave an estimate of the Inhibition concentration ($K_I$) of free ammonia to be 21.3 mg $NH_3$-N/L. Previous studies gave $\hat{K}_{NO}$ of Nitrobacter and Nitrospira as 0.120 and 0.032 mg/mg VSS h. The free ammonia concentration which inhibits Nitrobacter was $30{\sim}50\;mg$ $NH_3$-N/L and Nitrospira was inhibited at $0.04{\sim}0.08\;mg$ $NH_3$-N/L. The results support the fact that Nitrobacter is the dominant NOB in the reactor. The variations in the reported values of free ammonia inhibition may be due to the different species of nitrite oxidizers present in the reactors. The respirometric method provides rapid and reliable analysis of the behavior and community of the nitrite oxidizing bacteria.