• Title/Summary/Keyword: ammonia and phosphorus removal

Search Result 54, Processing Time 0.024 seconds

Effects of phosphorus concentration and nitrogen sources on photoautotrophic microalgae Scenedesmus dimorphus applied wastewater treatment (인 농도 및 질소원이 광합성 미세조류인 Scenedesmus dimorphus를 이용한 하수고도처리에 미치는 영향)

  • Kim, Tae-Hyeong;Cho, Yong-Beom;Park, Jeong-Eun;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.325-329
    • /
    • 2013
  • A result of estimating the effects of initial phosphorus concentration and nitrogen sources on removal of nitrogen and phosphorus in wastewater treatment using Scenedesmus dimorphus shows that there was no difference in microalgae growth amount and nitrogen removal amount by phosphorus concentration(5 ~ 60 mg/L). On the other hand, as initial phosphorus concentration increased, phosphorus removal amount was increased by luxury uptake of microalgae. Scenedesmus dimorphus preferred to ammonia when ammonia(40 mg/L) and nitrate(40 mg/L) are simultaneously presented and nitrogen removal rate of ammonia was high at approximately 20 mg/L/day.

Treatment of Piggery Wastewater by Anoxic-Oxic Biofilm Process (준혐기-호기 생물막 공정을 이용한 돈사폐수 처리)

  • 임재명;한동준
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 1997
  • This research aims to develop biofilm process for the nutrient removal of piggery wastewater. The developed process is the four stage anoxic-oxic biofilm process with recirculation of the final effluent. In summery, the results are as follows: 1. Nitrification in the piggery wastewater built up nitrite because of the high strength ammonia nitrogen. The nitrification of nitrobacter by free ammonia was inhibited in the total ammonia nitrogen loading rate with more than 0.2 kgNH$_{3}$-N/m$^{3}$·d. 2. The maximal total ammonia nitrogen removal rate was obtained at 22$\circ $C and without being affected by the loading rate. But total oxidized nitrogen production rate was largely affected by loading rate. 3. Autooxidation by the organic limit was a cause of the phosphorus release in the aerobic biofilm process. But the phosphorus removal rate was 90 percent less than the influent phosphorus volumetric loading rate of above 0.1 kgP/m$^{3}$·d. Therefore, the phosphorus removal necessarily accompanied the influent loading rate. 4. On the anoxic-oxic BF process, the total average COD mass balance was approximately 67.6 percent. Under this condition, the COD mass removal showed that the cell synthesis and metabolism in aerobic reactor was 42.8 percent and that the denitrification in anoxic reactor was 10.7 percent, respectively.

  • PDF

Nitrification of low concentration ammonia nitrogen using zeolite biological aerated filter (ZBAF)

  • Kim, Jin-Su;Lee, Ji-Young;Choi, Seung-Kyu;Zhu, Qian;Lee, Sang-Ill
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.554-560
    • /
    • 2020
  • This study focuses on nitrification through a biological aerated filter (BAF) that is filled with a zeolite medium at low concentrations of ammonia. The zeolite medium consists of natural zeolite powder. The BAF is operated under two types of media, which are a ball-type zeolite medium and expanded poly propylene (EPP) medium. Nitrification occurred in the zeolite BAF (ZBAF) when the influent concentration of ammonia nitrogen was 3 mg L-1, but the BAF that was filled with an EPP medium did not experience nitrification. The ammonia nitrogen removal efficiency of ZBAF was 63.38% and the average nitrate nitrogen concentration was 1.746 mg/L. The ZBAF was tested again after a comparison experiment to treat pond water, and municipal wastewater mixed pond water. The ZBAF showed remarkable ammonia-nitrogen treatment at low concentration and low temperature. During this period, the average ammonia nitrogen removal efficiency was 64.56%. Especially, when water temperature decreased to 4.7℃, ammonia nitrogen removal efficiency remained 79%. On the other hand, the chemical-oxygen demand (COD) and phosphorus-removal trends were different. The COD and phosphorus did not show as efficient treatment as the ammonia-nitrogen treatment.

Ammonia Removal by Use of Zeolite at Small Wastewater Treatment System (소규모 오수처리시스템에서의 제올라이트에 의한 암모니아성 질소 제거(지역환경 \circled3))

  • 방천희;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.643-648
    • /
    • 2000
  • The purpose of this study is to remove the ammonia by using the ion exchange effect of natural zeolite (clinoptilolite in this system) and artificial zeolite and remove the organic material by using the Absorbent Biofilter. On the removal of ammonia, natural zeolite is the more effective than artificial zeolite But on the simultaneous removal of ammonia and phosphorus, artificial zeolite is the more effective than natural zeolite.

  • PDF

Performance Assessment of Electrolysis Using Copper and Catalyzed Electrodes for Enhanced Nutrient Removal from Wastewater

  • Kim, Woo-Yeol;Son, Dong-Jin;Yun, Chan-Young;Kim, Dae-Gun;Chang, Duk;Sunwoo, Young;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.124-132
    • /
    • 2017
  • The performance of electrolytic processes using copper and catalyzed electrodes for enhanced nutrient removal with various catalyzers and combinations of electrodes was evaluated. The catalyzed electrodes removed more ammonia nitrogen than the copper electrode, but higher ammonia removal was achieved using a Pt/Ti anode. On the other hand, electrolysis using the Pt/Cu anode consumed less energy and cost less. During electroreduction, nitrate was better removed by a pair of copper electrodes than by the catalyzed electrodes. During electrolysis of synthetic wastewater, ammonia removal not only increased owing to direct oxidation at the anode, but was also influenced by indirect oxidation at the cathode. Platinum-coated copper and titanium cathodes actively produced oxidizers and thus removed more ammonia than a pure metal cathode. Although phosphorus was removable irrespective of the type of catalyzer, electrocoagulation using the copper electrode achieved complete removal of phosphorus in a period of less than 10 min.

Effects of pH, molar ratios and pre-treatment on phosphorus recovery through struvite crystallization from effluent of anaerobically digested swine wastewater

  • Kim, Daegi;Min, Kyung Jin;Lee, Kwanyong;Yu, Min Sung;Park, Ki Young
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.12-18
    • /
    • 2017
  • Struvite precipitation has been proven to be an effective method in removing and recovering ammonia nitrogen (N) and phosphate phosphorus (P) from wastewater. In this study, effects of pH, molar ratios and pre-treatment of effluent of anaerobically digested swine wastewater were investigated to improve struvite crystallization. The magnesium : ammonium : phosphate ratio of 1.2 : 1.0 : 1.0 was found to be optimal, yet the molar ratio in the wastewater was 1 : 74.9 : 1.8. From the analysis, the optimum pH was between 8.0 and 9.0 for maximal phosphate P release and from 8.0 to 10.0 for maximal ammonia N and phosphate P removal from real wastewater. Analysis from Visual MINTEQ predicted the pH range of 7-11 for ammonia N and phosphate P removal and recovery as struvite. For pre-treatment, microwave pre-treatment was ineffective for phosphate P release but ultrasound pre-treatment showed up to 77.4% phosphate P release at 1,000 kJ/L of energy dose. Precipitates analysis showed that phosphorus and magnesium in the collected precipitate had almost same values as theoretical values, but the ammonia content was less than the theoretical value.

Factors Influencing the Removal of Nutrient by Seawater (해수에 의한 영양염 제거에 있어서 영향인자의 평가)

  • Cortes, Aiza;Kim, Woo-Hang
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.145-147
    • /
    • 2009
  • Nutrients in wastewater should be removed prior to release in the receiving waters to prevent the occurrence of eutrophication. In this study, seawater is used to remove ammonia and phosphate by the formation of struvite ($MgNH_{4}PO_{4}{\cdot}6H_{2}O$). It aims to know the optimum conditions for the removal of nutrients using seawater as source of magnesium ions. Experiments were performed using jar tester and pH of ammonium-phosphate solutions were adjusted Samples were drawn at different mixing times. It was shown that simultaneous removal of ammonia and phosphate is rapid, with no significant reduction beyond 10 min of mixing Another important parameter is pH, where range 10-11 showed the optimum nutrient removal. Increase in the volume of seawater, which meant an increase in magnesium ions also lead to better removal.

  • PDF

Reaction Characteristics of Piggery Wastewater for Biological Nutrient Removal (생물학적 영양염류 제거를 위한 돈사폐수의 반응 특성)

  • 한동준;류재근;임연택;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • This study was performed to investigate the reaction characteristics of piggery wastewater for biological nutrient removal. The reaction characteristics were discussed the fraction of organics, the behavior of nitrogen, nitrification, denitrification, and the behavior of phosphorus. The fraction of readily biodegradable soluble COD was 11-12 percent. The ammonia nitrogen was removed via stripping, nitrification, autotrophic cell synthesis, and heterotrophic cell synthesis. The removal percents by each step were 12.1%, 68.9%, 15.0%, and 4.0%, respectively. Nitrification inhibition of piggery wastewater was found to occur at an influent volumetric loading rate over 0.2 NH$_{3}$-N kg/m$^{3}$/d. Denitrification rates were the highest in the raw wastewater and the lowest in the anaerobic effluent. The denitritation of piggery wastewater came out to be possible, and the rate of organic carbon consumption decreased about 10 percent. The phosphorus removed was released in the form of ortho-p in the aerobic fixed biofilm reactor, it was caused by autooxidation. The synthesis and release of phosphorus were related to the ORP and the boundary value for the phase change was about 170mV. In the synthesis phase, the phosphorus removal rate per COD removed was 0.023mgP$_{syn}$/mgCOD$_{rem}$. The phosphorus contents of the microorganism were 4.3-6.0% on a dry weight basis.

  • PDF

Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes (유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation (전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.