• Title/Summary/Keyword: amalgam

Search Result 301, Processing Time 0.026 seconds

A STUDY ON THE GALVANIC CURRENT BETWEEN GOLD AND AMALGAM (아말감과 금합금의 Galvanic 전류 측정에 관한 실험적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1984
  • It was the purpose of this study to determine the galvanic current between a gold alloy inlay and four types of amalgam using the circuit through pulp chambers when the freshly extracted teeth with those restorations were brought into contact in a physiologic saline solution, and to investigate the effectiveness of cavity varnish or ammonated silver-nitrate on the surface of amalgam restoration in reducing galvanic current. The current was measured with current-to-voltage converter and recored on a physiograph 6630-257. The following results were obtained. 1. Generally, galvanic current decreased as the time elapsed. 2. Galvainc current decreased significantly in the first day and after then minimal change was observed until 30th day. 3. Initial galvanic current was 29.6 ${\mu}A$ in the cut amalgam and 24.5 ${\mu}A$ in Dispersalloy amalgam and after then the current was significantly decreased. 4. Initial galvanic current was 12.6 ${\mu}A$ in spherical amalgam (low copper amalgam) and 13.8 ${\mu}A$ in Tytin amalgam and the amount of change was lower in sperical amalgam and Tytin amalgam than that in lathe cut amalgam and Dispersalloy amalgam. 5. Painting ammoniated silver-nitrate or Copalite on the surface of amalgam resotration decreased initial galvanic current and ammoniated silver-nitrate is more effective in decreasing galvanic current than Copalite. 6. Galvanic current by contact between amalgam restoration and gold restoration increased abruptly and dropped rapidly becoming almost.

  • PDF

A STUDY ON THE MICROSTRUCTURES OF THE AMALGAM ALLOYS AND AMALGAMS (치과용 아말감합금 및 아말감의 마세구조에 관한 연구)

  • Yeon, Sang-Heum;Lee, Chung-Sik;Lee, Myung-Jong;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.87-105
    • /
    • 1996
  • The purpose of this study is to investigate the characteristics of the compositions and phases of amalgam alloys and amalgams by using EMPA and X-ray diffractometer. Each specimen was made from Caulk Fine Cut Clow copper lathe cut amalgam), Caulk Spherical (low copper spherical amalgam), Tytin (high copper unicorn position amalgam), Dispersally (high copper admixed amalgam) and Valiant (Palladium enriched amalgam). For preparing amalgam alloys, Tytin and Valiant were used as powder forms and the others were used as tablet forms after being polished with polishing machine. For preparing amalgams, each amalgam alloy and Hg were measured, and triturated by mechanical amalgamater according to user's instructions. After triturating, the triturated mass was inserted to cylindrical metal mold and simultaneously adapted by cylindrical condenser with same diameter and condensed by Instron universal testing machine with 80kg pressure & 1mm/min speed. Each specimen was removed from the metal mold and stored at room temperature for a week. The specimen was polished with the same polishing machine for amalgam alloy. For observation of microstructure and analysis of composition of amalgam alloys and amalgams, EMPA was used to get secondary electron images, backscattered images and characteristic X-ray images of Ag, Sn, Cu, Zn, Hg. To analyze compositions of amalgam alloys and amalgams, X-ray diffractometer was used. Amalgam alloys were scanned at the range of 2${\theta}$ of 30-$85^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line and amalgams were scanned at the range of 2${\theta}$ of 28-$44^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line. By comparing obtained d(distance between surfaces) and d of expected phases and atoms in amalgam alloys and amalgams in ASTM card, phases and atoms were identified. The results were as follows, 1. In Caulk Fine Cut amalgam alloy typical ${\gamma}$ phase was shown, and in amalgam, ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phases were observed. 2. In Caulk Spherical amalgam alloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, ${\gamma}_2$ and $\eta$ phases were observed. 3. In Tytin amalgam alloy ${\gamma}$, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 4. In Dispersalloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 5. In Valiant alloy ${\gamma}$, Cu and e phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed.

  • PDF

AN ELECTROCHEMICAL STUDY ON THE CORROSION OF DENTAL AMALGAM (치과용 아말감의 부식(腐蝕)에 관한 전기화학적 연구)

  • Chang, Gye-Bong
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.115-122
    • /
    • 1980
  • The corrosion of silver amalgam is regarded as one of major causes in the failures of dental amalgam restorations. To evaluate the corrosion resistance of dental amalgam alloys, electrochemical tests such as potential and polarization measurement were used widely. But these commonly used methods have not provided the sufficient informations on relative resistance of amalgam to corrosion. In this experiment, the corrosion currents were measured using electronic potentiostat to compare some commercial dental amalgam alloys. All alloys were triturated in a amalgamator and condensed into a mold described in A.D.A. Specification No. 1 to produce cylinder form specimens of 4mm diameter by 5mm long. After specimen kept for 1 week at $37^{\circ}C$, each specimen was embedded in epoxy resin. The surfaces of specimens were then polished with a emery paper, diamond dust, and $Al_2O_3$. These specimens were immersed in artifical saliva kept at $37^{\circ}C$, and currents of each specimen were measured for 24 hours at 0.0volt (SCE). The author obtained conclusions as follows: 1. High copper amalgam showed superior resistance against corrosion to conventional amalgam, but a pellet form of high copper amalgam seemed to be susceptible to corrosion. 2. In lathe-cut alloys, fine-cut had superior resistance against corrosion to regular-cut. 3. Non-zinc conventional amalgam alloys were more resistant to corrosion than that of zinc containing conventional amalgam alloys. 4. In both of high copper and conventional amalgams, predispensed forms tended to have better resisitance to corrosion than that of pellet forms.

  • PDF

AN ELECTROCHEMICAL STUDY ON SURFACE FINISH OF DENTAL AMALGAM (아말감의 표면연마에 관한 전기화학적 연구)

  • Suk, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.18-32
    • /
    • 1991
  • The purpose of this study was to observe characteristic properties of amalgam through the polarization curves and SEM images from 4 type amalgams (Amalcap, Shofu spherical. Dispersalloy and Tytin) with 3 different surface finish procedures (polishing, burnishing and carving) by using the potentiostats (EG & GPARC) and SEM (Jeol JSM-35). After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of mechanical amalgamator (Samki), the triturated mass was inserted into the cylndrical metal mold which was 12 mm in diameter and 10 mm in height and was pressed with $100kg/cm^2$. 4 specimens of each type amalgam were burnished with egg burnisher and another 4 specimens of each type amalgam were carved with Hollenback carver. Above 8 specimens and remaining untreated 4 specimens were stored at room temperature for about 7 days. Untreated 4 specimens of each type amalgam were polished with abrasive papers (Deer) from #400 to #1200 and finally on the polishing cloth with $0.5{\mu}m$ and $0.06{\mu}m$ $Al_2O_3 $ powder suspended water. Anodic polarization measurements was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution at $37^{\circ}C$. The open circuit potential was determined after 30 minutes immersion of specimen in electrolyte. The scan rate was 1 mV/sec and the surface area of amalgam exposed to the solution was $0.64cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). SEM images of each specimen were taken after + 800 mV (SCE) polarization. The results were as follows: 1. The corrosion potential of high copper amalgam was more anodic than that of low copper amalgam. 2. The polished amalgam were more resistant to corrosion than any other burnished and carved amalgam. 3. In the case of polishing, current density of high copper amalgam was lower than that of low copper amalgam.

  • PDF

Association between amalgam removal and urinary mercury concentration: a pilot study (아말감 충전물 제거와 뇨중 수은농도의 관련성 평가: 예비연구)

  • Baek, Hye-Jin;Sa, Kong-Joon;An, Seo-Young;Lee, Hee-Kyung;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.431-438
    • /
    • 2012
  • Objectives : The aim of this study was assessment of the variation of urinary mercury concentrations after removal of amalgam fillings in children. Methods : 10 elemental school children with amalgam filling tooth surfaces were took part in this study. One dentist recorded the number of amalgam filling surface, and general characteristics of subjects were surveyed by questionnaire. Each urine samples were collected before, immediately after and after 24 hours amalgam removal. The statistical analysis was performed using the SPSS 18.0. Results : The mean concentration urinary mercury immediately after amalgam removal was higher ($5.70{\pm}1.20{\mu}g/g$ creatinine) than before amalgam removal ($5.28{\pm}1.53{\mu}g/g$ creatinine). The mean concentration urinary mercury level whose have 1-10 amalgam removal surfaces was increased after amalgam removal compared with before. Conclusions : Mercury concentration in urine was influenced by amalgam removal.

A STUDY ON THE REDUCTION OF GALVANIC CURRENT BETWEEN AMALGAM AND GOLD ALLOY WITH VARIOUS CHEMICAL AGENTS (수종 아말감과 금합금의 갈바닉 전류 측정에 관한 연구)

  • Kim, Seung-Soo;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.469-481
    • /
    • 1993
  • The purpose of this study was to achieve the reduction of the galvanic current between the dental amalgam alloy and gold alloy. In order to measure the galvanic current between these two metals a prep in the size of $4{\times}13mm$ which was filled with amalgam and another prep of $4{\times}2mm$ was filled with gold alloy was made in the acrylic resin. These two preps were then connected to a 2mm diameter copper wire. Using an ammeter to measure the galvanic current, six different kinds of amalgam and gold alloy were immersed in saline solution with approximately 10mm distance between the two alloys. Chemical agents that are thought to reduce the galvanic current such as hydrazine. silver nitrate, potassium chromate, and bonding agents such as Scotch bond 2(3M) and All bond 2(Bisco) were applied to the alloy surface. Cathodic inhibitor such as hydrazine was applied to gold alloy where as anodic inhibitor such as silver nitrate and potassium chromate were applied to amalgam. Both bonding agents, Scotch bond 2(3M) and All bond 2 (Bisco), were applied to amalgam. The following results were obtained when the currency on the coated alloy surface was compared to the uncoated surface. 1. The galvanic currency went down as the time elapsed and after 30 minutes no change was detected. 2. Initial currency was higher in low copper amalgam compared to high copper amalgam. Intitial currency was the highest in low copper lathe-cut amalgam. 3. Group of gold coated with hydrazine had the most reduction in galvanic currency. 4. Group of amalgam coated with silver nitrate or potassium chromate also showed significant reduction in galvanic currency. 5. The bonding agents also helped reduce galvanic currency. 6. Of all the agents used to reduce galvanic currency, silver nitrate showed the best result.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN TO AMALGAM ACCORDING TO AMALGAM SURFACE TREATMENT METHODS (아말감의 표면처리에 따른 복합레진과의 전단결합 강도에 관한 연구)

  • Park, Mun-Hee;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.114-121
    • /
    • 1993
  • The purpose of this study was to evaluate the effect on treatment methods to shear bond strength between composite resin and amalgam when the alloy surface was finished with a diamond wheel or an sandblaster. Forty round acrylic cylinders were fabricated with a diameter of 33mm and a height of 20mm to fit into the device used during shear bond strength testing. A round undercut cavity (diameter, 8mm: depth, 2.5mm) was prepared in the center of the acrylic surface and the cavity was restored using a amalgam. A total of 40 acrylic cylinders with amalgam were divided into 4 groups according to treatment method. The group treatment were as follows : Group 1 : acid etching after finishing the amalgam with diamond wheel Group 2 : no acid etching after finishing the amalgam with diamond wheel Group 3 : acid etching after sandblasting the amalgam Group 4 : no acid etching after sandblasting the amalgam The shear bond strength of composite resin bonded to amalgam of each specimen was tested with a universal testing machine at a crosshead speed of 0.5mm/min and 500kg in full scale. The results were as follow: 1. After diamond finishing, the non-acid etching group had highest shear bond strength with 7.29kg/$cm^2$ and after sandblasting, the acidetching group had lowest shear bond strength with 4.49kg/$cm^2$. 2. In both diamond finishing and sandblasting group, acid etching of the roughened amalgam surface decreased the shear bond strength. 3. The group treated with a diamond wheel had higher shear bond strength those treated with an sandblaster but there was not significanat.

  • PDF

THE STUDY ON LONGEVITY OF AMALGAM AND COMPOSITE RESIN (Amalgam과 composite resin 수복물의 수명에 관한 연구)

  • Um, Chung-Moon;Kim, Seung-Soo;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.501-506
    • /
    • 1993
  • The purpose of this study was to observe the longevity of amalgam and composite resin fillings in Korea. The number of placement of restorations was 760 amalgams and 415 composite resins. The amalgam restorations inserted because of primary caries were 61 % and replacement of amalgam restorations were 39%, and composite restorations inserted because of primary caries were 62 % and replacement of composite restorations were 38 %. The median longevity of failed amalgam restorations was 3 years and the madian longevity of failed composite restorations was 2 years. The main reason of replacement of amalgam and composite resin restorations was secondary caries.

  • PDF

Nickel Amalgamation by Electro-deposition Process Using Mercury Cathode and Its Properties (수은 음극 상 전착에 의한 니켈 아말감의 제조와 그 물성)

  • Kim, Ki-Ho
    • Journal of Surface Science and Engineering
    • /
    • v.38 no.5
    • /
    • pp.198-201
    • /
    • 2005
  • Nickel amalgam was Prepared by the electro-deposition with mercury cathode in a modified Watts bath. Homogeneous nickel amalgam was obtained. The fluidity of the amalgam decreased gradually with increased nickel quantity and become solid finally. Nickel powders of sub-micron size were obtained by a distillation of mercury from the amalgam. The characterization of the nickel amalgam was studied by SEM and x-ray diffractometry.

Correlation between amalgam restorations and urinary mercury level in children for 1 year (일부 대도시지역 혼합치열기 아동의 아말감 충전물과 뇨중 수은농도: 1년 추적조사)

  • Baek, Hye-Jin;Jeong, Seong-Hwa;Choi, Youn-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.3
    • /
    • pp.425-430
    • /
    • 2014
  • Objectives : The purpose of this study is to investigate the correlation between amalgam restorations and urinary mercury levels in children for 1 year. Amalgam restoration has been widely used for over 200 years. But released mercury from amalgam can increase the concentration of mercury in the body. Methods : The subjects were 463 elementary school children. Oral examination, urine sampling, and questionnaire survey were performed at baseline and after 1 year. Results : Amalgam restoration increased the urinary mercury level to $0.55{\pm}0.13{\mu}g/g$ creatinine. In the regression analysis, variation of urinary mercury excretion were positively associated with amalgam surfaces and fish consumption. Conclusions : Small amount of mercury release from amalgam restoration was closely associated with increasing urinary mercury level.