회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가 (Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir)

  • 맹민수;;김동현;신귀암;독고석
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Study of chemical coagulation conditions for a disperse red dye removal from aqueous solutions

  • Tiaiba, Mohammed;Merzouk, Belkacem;Mazour, Mohammed;Leclerc, Jean P.;Lapicque, Francois
    • Membrane and Water Treatment
    • /
    • 제9권1호
    • /
    • pp.9-15
    • /
    • 2018
  • Coagulation process using aluminum sulfate ($Al_2(SO_4)_3$) and ferric chloride ($FeCl_3$) was employed as a treatment method for decolorization of a synthetic textile wastewater containing red dye in this paper. Factors such as initial pH, coagulant dosage, initial concentration, conductivity and mixing conditions that influence color removal efficiency were experimentally tested. It was found that $Al_2(SO_4)_3$ is more efficient than $FeCl_3$ as coagulant. When $40mgL^{-1}$ aluminum sulfate was used, results showed that color induced by the red dye was efficiently removed (> 90 %) and was obtained in a large range of initial pH from 4 to 8 with, and for a dye concentration lower than $235mg\;L^{-1}$. After addition of the coagulant, the medium had to be mixed for 30 min at 60 rpm, then allowed to settle for 40 min. The effects of water conductivity in the range $0.035-2.42mS\;cm^{-1}$ and dye concentration up to $380mg\;L^{-1}$ were also followed and discussed.

Application of nanofiltration membrane in the recovery of aluminum from alkaline sludge solutions

  • Cheng, Wen Po;Chi, Fung Hwa;Yu, Ruey Fang;Tian, Dun Ren
    • Advances in environmental research
    • /
    • 제5권2호
    • /
    • pp.141-151
    • /
    • 2016
  • Large amounts of aluminum hydroxide ($Al(OH)_3$) exist in water purification sludge (WPS) because of the added aluminum coagulant in water treatment process. Notably, $Al(OH)_3$ is an amphoteric compound, can be dissolved in its basic condition using sodium hydroxide to form aluminate ions ($Al(OH)_4{^-}$). However, in a process in which pH is increasing, the humid acid can be dissolved easily from WPS and will inhibit the recovery and reuse of the dissolved aluminate ions. This study attempts to fix this problem by a novel approach to separate $Al(OH)_4{^-}$ ions using nanofiltration (NF) technology. Sludge impurity in a alkaline solution is retained by the NF membrane, such that the process recovers $Al(OH)_4{^-}$ ions, and significantly decreases the organic matter or heavy metal impurities in the permeate solution. The $Al(OH)_4{^-}$ ion is an alkaline substance. Experimental results confirm that a recovered coagulant of $Al(OH)_4{^-}$ ion can effectively remove kaolin particles from slightly acidic synthetic raw water.

응집과 균질화가 팽화슬러지의 용존공기부상과 침전에 미치는 영향 (Effect of Coagulation and Homogenization on the Dissolved Air Flotation and Sedimentation of Bulking Sludge)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.68-74
    • /
    • 2007
  • The objective of this study is to examine the effect of the coagulation and homogenization in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effects of parameters such as dosage of coagulant and homogenization time were examined. The results showed that DAF and sedimentation was affected aluminum sulfate and anion polymer coagulant differently. At the optimum dosage of aluminum sulfate, thickening efficiency of DAF and sedimentation process were increase 1.25 time and 2.02 time, respectively. At the optimum dosage of anion polymer coagulant, thickening efficiency of DAF process was increase 1.35 time, but thickening efficiency at sedimentation was 1.06 time. When anion polymer coagulant of 0.5 mg/l was added in DAF process, water content of sludge was decreased from 96.6% to 90.7% in dewatering process using Buchner funnel test device. After homogenization(20500 rpm, 10 min), Sauter mean diameter of sludge floc was decreased from 631 ${\mu}m$ to 427 ${\mu}m$, however increase of flotation efficiency by DAF was only 1.09 time.

원수 수질특성과 응집제 염기도에 따른 응집 pH 및 주입량의 영향 (The Effects of pH and Dosages According to Qualities of Raw Waters and Basicity of Coagulants)

  • 박노백;이범;전동걸;이영주;전항배
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.581-593
    • /
    • 2010
  • The objectives of this study were to investigate the effects of raw water pH and basicity of coagulants on turbidity removal with several raw waters having different level of turbidity, alkalinity and pH. Raw waters were sampled from M, S and B water treatment plants(WTP) located at Miryang, Nakdong, Han river, respectively. Six coagulants which have different levels of basicity and aluminum contents were used for this evaluation. High basicity of the coagulant helped to properly control coagulation processes for treating turbid and low alkali raw water. It was difficult for operators to determine optimum coagulant dose for high basicity coagulants, since residual turbidity tended to decrease continuously as coagulant dose increased. Turbidity removal efficiencies with high basicity coagulants(E and F) were higher than the other coagulants at ambient pH for the M WTP. Turbidity removal efficiencies, however, at adjusted pH 7.0 showed similar among six coagulants. Residual turbidity kept low at excess dosages with high basicity coagulants. Optimum coagulant dosages at adjusted pH 7.0 showed higher than those at ambient pH in M WTP. On the contrary in B WTP, optimum coagulant dosage at ambient pH were higher than that at adjusted pH 7.0.

탁도와 총유기탄소 제거를 위한 최적응집제 및 투여량 선정 연구 (Optimal coagulant and its dosage for turbidity and total organic dissolved carbon removal)

  • 박한배;우달식
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2321-2327
    • /
    • 2015
  • 본 연구는 급격한 수질변화에 따른 현장 적용에 적합한 응집제를 선정하고, 응집제 별 최적 주입량을 찾기 위해 aluminium sulfate, poly aluminum chloride, poly aluminum silicate chloride를 이용하여 Jar-Test와 Pilot-Test의 검증으로 실험 하였다. 분석 항목은 탁도, TOC, pH로 제거율을 측정하였다. 실험 결과를 바탕으로 PASC의 경우 기존 응집제 인 Alum이나 PAC 보다 최적 주입량 (15 mg/L)이 상대적으로 적었으며, 제거율도 높게 나타남을 확인할 수 있었다. Jar-Test에서는 원수 탁도 3-20 NTU 범위에서 응집제(PASC)의 최적 주입량을 주입하였을 때, 탁도 제거율(80%)과 TOC 제거율(89%)이 가장 높았으며, Pilot-Test에서는 원수 탁도 3.6-27 NTU 범위에서 응집제 최적 주입량을 주입하였을 때 탁도 제거율(82%)과 TOC 제거율(88%)을 확인할 수 있었다. 따라서 본 연구 결과를 바탕으로 응집제의 제거 효과는 원수 탁도와 TOC가 높아질수록 상승하는 경향을 확인할 수 있었다.

재생지 폐수의 최적 응집조건 결정에 관한 연구 (Studies on the Determination of Optimal Flocculation Condition in Wastewater of Recycled Paper)

  • 이성호;임택준;조준형
    • 펄프종이기술
    • /
    • 제33권3호
    • /
    • pp.44-51
    • /
    • 2001
  • Sedimentation characteristics such as SS, $BOD_5$, COD removal efficiency of waste water in the toilet paper mill using milk carton were examined. Optimum dosage of coagulant, rapid mixing time and slow mixing time were determined by turbidity, SS, COD, $BOD_5$ and then equation for treatment efficiency was suggested. Mechanical strength of floc was determined by turbidity. For the coagulant, polyacrylamide (PAM) is more efficient for removing pollution than the aluminium sulfate. Effective mixing ratios of PAM and aluminum sulfate to remove pollution are 70:30 and 30:70. The lowest turbidity was showed when rapid mixing at 300 rpm after coagulant injection was applied. That which indicates the highest point of flocs mechanical strength.

  • PDF

Coagulation and Flotation Conditions of Humic Acid by Dissolved Air Flotation

  • Lee, Chang-Han
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1043-1051
    • /
    • 2012
  • Coagulation, flocculation, and dissolved air flotation (DAF) experiments were performed with humic acid to evaluate the influence of operational conditions on removal efficiencies. We investigated coagulation, flocculation, and flotation conditions of humic acid removal using a laboratory-scale DAF system. This paper deals with coagulant type (aluminum sulfate and PSO-M) and the most relevant operational conditions (velocity gradients for coagulation and flocculation, retention time and recycle ratio and flotation time). Results showed that optimal conditions for removing humic acid, yielding CHA removal efficiencies of approximately 85 %, are a recycle ratio of 40 %, coagulant dosages of 0.15 - 0.20 gAl/gHA as aluminum sulfate and 0.03 - 0.12 gAl/gHA as PSO-M, coagulation($400s^{-1}$ and 60s), flocculation($60s^{-1}$ and 900s or more), and flotation(490 kPa or more and at least 10 min).

응집제 종류에 따른 RO막 표면 흡착 특성 (Characteristics of Adsorption on the RO Membrane Surface by Coagulants Types)

  • 정영미;박찬혁;이상협;권지향
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.477-483
    • /
    • 2007
  • A coagulation process for RO (reverse osmosis) membrane pretreatment system was an effective technology to remove colloidal and particulate matters. However, coagulant residuals from the pretreatment process may negatively affect RO membrane performance. The bench-scale coagulant exposure study was performed to investigate the effect of their residual on adsorbed mass which related to the membrane performance. Coagulant addition in this study ranged from 0 to 5mg/L ferric chloride, alum, and 2mg/L cationic polymer(poly-di-methyldiallyl ammonium chloride) as coagulant aids. This results showed that adsorbed mass is not significantly increased during short-time period, however, accumulated mass of coagulants on the membrane surface is significantly increased during long-time experimental period. The effect of pH on coagulants adsorption characteristics was significantly differed due to the electrostatic repulsive interactions between soluble coagulants and membrane surface charge. This data suggest that the RO membrane performance of drinking water treatment plant could be decreased by adsorption of residual coagulants when applied for the coagulant pretreatment process.

반응표면분석법을 이용한 터널폐수 응집-혼화 공정의 주요인자 영향 분석 및 최적화 (Utilization of response surface methodology to optimize a coagulation-flocculation process for tunnel wastewater treatment)

  • 정세욱;이재현;박태원;김영모
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.601-608
    • /
    • 2014
  • A coagulation-flocculation (CF) process using aluminum sulfate as a coagulant was employed to treat highly suspended solids in tunnel wastewater. Response surface methodology (RSM) based on a Box-Behnken design was applied to evaluate the effects of three factors (coagulant dosage, pH and temperature) on total suspended solids (TSS) removal efficiency as well as to identify optimal values of those factors to maximize removal of TSS. Optimal conditions of coagulant dosage and pH for maximum TSS removal changed depending on the temperature ($4{\sim}24^{\circ}C$). As temperature increased, the amount of coagulant dosage and pH level decreased for maximum TSS removal efficiency during the CF process. Proper adjustment of optimal pH and coagulant dosage to accommodate temperature fluctuations can improve TSS removal performance of the CF process.