Optimal Design of Magnetically Levitated Flywheel Energy Storage System Based on System Stability Using Rigid-Body Model (강체모델 기반 시스템 안정성을 고려한 자기부상 플라이휠 에너지 저장장치의 최적 설계)

  • Kim, Jung-Wan;Yoo, Seong-Yeol;Bae, Yong-Chae;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2010
  • Owing to the increasing worldwide interest in green technology and renewable energy sources, flywheel energy storage systems (FESSs) are gaining importance as a viable alternative to traditional battery systems. Since the energy storage capacity of an FESS is proportional to the principal mass-moment of inertia and the square of the running speed, a design that maximizes the principal inertia while operatingrunning at the highest possible speed is important. However, the requirements for the stability of the system may impose a constraint on the optimal design. In this paper, an optimal design of an FESS that not only maximizes the energy capacity but also satisfies the requirements for system stability and reduces the sensitivity to external disturbances is proposed. Cross feedback control in combination with a conventional proportional-derivative (PD) controller is essential to reduce the effect of gyroscopic coupling and to increase the stored energy and the specific energy density.

A Survey on RF Energy Harvesting System with High Efficiency RF-DC Converters

  • Khan, Danial;Basim, Muhammad;Ali, Imran;Pu, YoungGun;Hwang, Keum Cheol;Yang, Youngoo;Kim, Dong In;Lee, Kang-Yoon
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-30
    • /
    • 2020
  • Radio frequency (RF) energy harvesting technology have become a reliable and promising alternative to extend the lifetime of power-constrained wireless networks by eliminating the need for batteries. This emerging technology enables the low-power wireless devices to be self-sustaining and eco-friendly by scavenging RF energy from ambient environment or dedicated energy sources. These attributes make RF energy harvesting technology feasible and attractive to an extended range of applications. However, despite being the most reliable energy harvesting technology, there are several challenges (especially power conversion efficiency, output DC voltage and sensitivity) poised for the implementation of RF energy harvesting systems. In this article, a detailed literature on RF energy harvesting technology has been surveyed to provide guidance for RF energy harvesters design. Since signal strength of the received RF power is limited and weak, high efficiency state-of-the-art RF energy harvesters are required to design for providing sufficient DC supply voltage to wireless networks. Therefore, various designs and their trade-offs with comprehensive analysis for RF energy harvesters have been discussed. This paper can serve as a good reference for the researchers to catch new research topics in the field of RF energy harvesting.

Design of an Infrared Multi-touch Screen Controller using Stereo Vision (스테레오 비전을 이용한 저전력 적외선 멀티 터치스크린 컨트롤러의 설계)

  • Jung, Sung-Wan;Kwon, Oh-Jun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.68-76
    • /
    • 2010
  • Touch-enabled technology is increasingly being accepted as a main communication interface between human and computers. However, conventional touchscreen technologies, such as resistive overlay, capacitive overlay, and SAW(Surface Acoustic Wave), are not cost-effective for large screens. As an alternative to the conventional methods, we introduce a newly emerging method, an optical imaging touchscreen which is much simpler and more cost-effective. Despite its attractive benefits, optical imaging touchscreen has to overcome some problems, such as heavy computational complexity, intermittent ghost points, and over-sensitivity, to be commercially used. Therefore, we designed a hardware controller for signal processing and multi-coordinate computation, and proposed Infrared-blocked DA(Dark Area) manipulation as a solution. While the entire optical touch control took 34ms with a 32-bit microprocessor, the designed hardware controller can manage 2 valid coordinates at 200fps and also reduce energy consumption of infrared diodes from 1.8Wh to 0.0072Wh.

3-D Pose Estimation of an Elliptic Object Using Two Coplanar Points (두 개의 공면점을 활용한 타원물체의 3차원 위치 및 자세 추정)

  • Kim, Heon-Hui;Park, Kwang-Hyun;Ha, Yun-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.23-35
    • /
    • 2012
  • This paper presents a 3-D pose (position and orientation) estimation method for an elliptic object in 3-D space. It is difficult to resolve the problem of determining 3-D pose parameters with respect to an elliptic feature in 3-D space by interpretation of its projected feature onto an image plane. As an alternative, we propose a two points-based pose estimation algorithm to seek the 3-D information of an elliptic feature. The proposed algorithm determines a homogeneous transformation uniquely for a given correspondence set of an ellipse and two coplanar points that are defined on model and image plane, respectively. For each plane, two triangular features are extracted from an ellipse and two points based on the polarity in 2-D projection space. A planar homography is first estimated by the triangular feature correspondences, then decomposed into 3-D pose parameters. The proposed method is evaluated through a series of experiments for analyzing the errors of 3-D pose estimation and the sensitivity with respect to point locations.

A STUDY ON A COMPARISON BETWEEN IN-VIVO AND IN-VITRO PHOTOTOXICITY TEST (IN-VIVO와 IN-VITRO에서의 광독성 시험법의 비교에 대한 연구)

  • Lee, Ho;Koh, Jae-Sook;Park, Won-Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.57-76
    • /
    • 1993
  • Phototoxicity is a complex phenomenon which may involve photochemical reaction and biological response mechanism. This complexicity and iii mal protecting tendency has led to the development of various in-vitro approaches as sensitive, alternative test to the in-vivo phototoxicity test. In this study, we investigated not only the sensitivity of two microorganism, (C. albicans and 5. typhimurium TA 98 about UV) but also a correlation between in-vitro and in-vivo phototoxicity test using UV A and 1 Furthermore, we studied the effect of irradiation method which were as follows 1) irradiate to material and microorganism, simultaneously 2) irradiate to only material 3) irradiate to material and microorganism, respectively In each irradiation method, it showed no significant difference, However we were able to observe the more sensitive phototoxicity in S. typhimurium TA 98 than C. albicans, and the results of in-vitro test using 5. typhimurium TA 98 had a good correlation with those of in-vivo test.

  • PDF

Draft genome sequence of lytic bacteriophage KP1 infecting bacterial pathogen Klebsiella pneumoniae (병원균 Klebsiella pneumoniae를 감염시키는 용균 박테리오파지 KP1의 유전체 염기서열 초안)

  • Kim, Youngju;Bang, Ina;Yeon, Young Eun;Park, Joon Young;Han, Beom Ku;Kim, Hyunil;Kim, Donghyuk
    • Korean Journal of Microbiology
    • /
    • v.54 no.2
    • /
    • pp.152-154
    • /
    • 2018
  • Klebsiella pneumoniae is a Gram-negative, rod-shape bacterium causing disease in human and animal lungs. K. pneumoniae has been often found to gain antimicrobial resistance, thus it has been difficult to treat K. pneumoniae infection with antibiotics. For such infection, bacteriophage can provide an alternative approach for pathogenic bacterial infection with antimicrobial resistance, because of its sensitivity and specificity to the host bacteria. Bacteriophage KP1 was isolated in sewage and showed specific infectivity to K. pneumoniae. Here, we report the draft genome sequence of Klebsiella pneumoniae phage KP1. The draft genome of KP1 is 167,989 bp long, and the G + C content is 39.6%. The genome has 295 predicted ORFs and 14 tRNA genes. In addition, it encodes various enzymes which involve in lysis of the host cell such as lysozyme and holin.

A Novel Balloon-Inflatable Catheter for Percutaneous Epidural Adhesiolysis and Decompression

  • Choi, Seong Soo;Joo, Eun Young;Hwang, Beom Sang;Lee, Jong Hyuk;Lee, Gunn;Suh, Jeong Hun;Leem, Jeong Gill;Shin, Jin Woo
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.178-185
    • /
    • 2014
  • Epidural adhesions cause pain by interfering with the free movement of the spinal nerves and increasing neural sensitivity as a consequence of neural compression. To remove adhesions and deliver injected drugs to target sites, percutaneous epidural adhesiolysis (PEA) is performed in patients who are unresponsive to conservative treatments. We describe four patients who were treated with a newly developed inflatable balloon catheter for more effective PEA and relief of stenosis. In the present patients, treatments with repetitive epidural steroid injection and/or PEA with the Racz catheter or the NaviCath did not yield long-lasting effects or functional improvements. However, PEA and decompression with the inflatable balloon catheter led to maintenance of pain relief for more than seven months and improvements in the functional status with increases in the walking distance. The present case series suggests that the inflatable balloon catheter may be an effective alternative to performing PEA when conventional methods fail to remove adhesions or sufficiently relieve stenosis.

Equilibrium of transport mode choice in logit model (로짓 수단선택모형의 균형연구)

  • Im, Yong-Taek
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.131-139
    • /
    • 2010
  • The transport mode choice problem is to determine which of the alternative transport modes connecting an origin and destination will be used by a traveler. Most of the research relating to transport mode choice have mainly been focused on modeling, properties, and applications of the model, but rarely were concerned with equilibrium among the modes. This paper proves the equilibrium among the modes by using a logit mode choice model, and then verifies it with the Korean Transport Database (KTDB). In order to obtain such an equilibrium, this paper also presents a solution algorithm based on the fixed point theorem. The algorithm was tested with an example and confirmed the equilibrium solution.

Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

  • Jang, Won-hee;Jung, Kyoung-mi;Yang, Hye-ri;Lee, Miri;Jung, Haeng-Sun;Lee, Su-Hyon;Park, Miyoung;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • v.23 no.4
    • /
    • pp.379-385
    • /
    • 2015
  • The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE$^{TM}$ which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE$^{TM}$ can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

Analysis of Simple Creep Stress Calculation Methods for Creep Life Assessment (크리프 수명 평가를 위한 간략 크리프 응력 산출 방법론 분석)

  • Seo, Jun Min;Lee, Han Sang;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.703-709
    • /
    • 2017
  • Creep analysis takes much more time than elastic or elastic-plastic analysis. In this study, we conducted elastic and elastic-plastic analysis and compared the results with creep analysis results. In the elastic analysis, we used primary stress, which can be classified by the $M{\alpha}-tangent$ method and stress intensities recommended in the ASME code. In the elastic-plastic analysis, we calculated the parameters recommended in the R5 code. For the FE models, a bending load, uniaxial load, and biaxial load were applied to the cross shaped welded plate, and a bending load and internal pressure were applied to the elbow pipe. To investigate the element size sensitivity, we conducted FE analysis for various element sizes for the cases where bending load was applied to the cross shaped welded plate. There was no significant difference between the creep stress and the alternative methods; however, in the $M{\alpha}-tangent$ method, the results were affected by the element size.