• Title/Summary/Keyword: allowable current

Search Result 291, Processing Time 0.025 seconds

An Overview of the Total Allowable Catch Policy and Fish Stock Assessments in Korea (총허용어획량제도 유래 및 국내 수산자원평가의 전반적 개요)

  • Saang-Yoon Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Since 2019, Korea Ministry of Oceans and Fisheries has set the annual total allowable catch (TAC) by fish species, and has allocated the annual TAC into each fishery vessel. Also the Korea government plans to adopt the individual transferrable quota system in time. The TAC allocation is similar to the individual fishermen/fishing quota, which the US National Oceanic and Atmospheric Administration has implemented. However, the TAC based management faced fishermen's complaints and a debate is still underway about how to allocate TAC. Because the ideas of the Korea policy are from those in the foreign countries, I intended to provide the Korea fisheries community with an overview about how the TAC has been developed, what problem it caused, and foreign examples of how to allocate it. Furthermore, I pointed out a substantial room for improvement in their current practice of stock assessments, because, otherwise, their current methods for estimation of TAC by species cannot be trusted. Finally I made specific suggestions about what they need to do to reform their current stock assessments.

Study on Frequency Selection Method Using Case-Based Reasoning for Cognitive Radio (사례기반 추론 기법을 이용한 인지 라디오 주파수 선택 방법 연구)

  • Park, Jae-Hoon;Choi, Jeung Won;Um, Soo-Bin;Lee, Won-Cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.58-71
    • /
    • 2019
  • This paper proposes architecture of a cognitive radio engine platform and the allowable frequency channel reasoning method that enables acquisition of the allowable channels for the military tactical network environment. The current military tactical wireless communication system is increasing need to secure a supplementary radio frequency to ensure that multiple wireless networks for different military wireless devices coexist, so that tactical wireless communication between the same or different systems can be operated effectively. This paper presents the allowable frequency channel reasoning method based on cognitive radio engine for realizing DSA(Dynamic Spectrum Access) as an optimal available frequency channel. To this end, a case-based allowable frequency channel reasoning method for cognitive radio devices is proposed through modeling of primary user's traffic status and calculation of channel occupancy probability. Also through the simulation of the performance analysis, changing rate of collision probability between the primary users' occupancy channel and the available channel acquisition information that can be used by the cognitive radio device was analysed.

Evaluation of Allowable Bearing Capacity of 600 mm Diameter Preboring PHC Piles Using Dynamic Load Test (직경 600mm PHC 매입말뚝의 동재하시험을 통한 허용 지지력 평가)

  • Woo, Gyu-Seong;Park, Jong-Bae;Seo, Mi-Jeong;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.11
    • /
    • pp.61-72
    • /
    • 2016
  • For the construction of high-rise structures and the optimized foundation design, the use of the large-diameter PHC pile has increased. Especially, the use of the 600 mm diameter PHC pile has significantly increased. In this study, for the evaluation of the suitability of the current design practice, the 46 dynamic pile load tests, which were carried out in the 600 mm diameter preboring PHC pile, are analyzed. The end bearing capacity is obtained from the end of initial driving test and the shaft capacity is estimated from the restrike test. The allowable capacities estimated by the dynamic load test are compared with those based on the current design practice. The analyses show that the allowable end bearing capacity evaluated by the dynamic pile load test is greater than the design practice in most piles. The allowable shaft capacity, however, is smaller than the design practice in many piles. The higher end bearing capacity and the smaller shaft capacity may result from the improvement of the drilling equipment and the increase in the penetration depth. Thus, the portion of the end bearing capacity in the total capacity increases.

A Comparative Study on the Evaluation of Bearing Capacity for Driven Pile in Static Load Test (현장정재하시험 결과를 통한 타입말뚝 지지력 판정법 비교 연구)

  • Chun, Byung-Sik;Seo, Deok-Dong;Choi, Heon-Kil;Yoon, Hwan-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.677-686
    • /
    • 2005
  • The allowable bearing capacity of a pile, the most important factor in stability estimation, is determined by applying safety factor to the ultimate load or yield load. There are several but contradictory methods available in current design codes to estimate the allowable bearing capacity and the safety factor. This paper analyzes load-settlement curves obtained from 19 static load tests measured from 11 sites. At all tests, the load is applied until apparent failure is observed. The validity of the ultimate and yield load estimation method and load caculated from the settlement criterion is investigated through comparison with the measured data. In addition, a new procedure to estimate allowable load and safety factor is proposed. Additional data from field static load tests, such as those incorporated in this study, are needed to more reliably apply the proposed method in design practice.

  • PDF

Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

  • Baek, Kwang Ki;Park, Chung Seo;Kim, Ki Hong;Chung, Mong Kyu;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities.

Study(III) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - The Proper Use of Long-term Allowable Compressive Load of PHC Piles by Analyzing Quality Test and Product Specifications Data - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(III) - 품질 성능 검사 자료 및 성능 제원 표 분석을 통한 PHC말뚝의 장기허용압축하중 성능의 올바른 활용 -)

  • Kim, Chae Min;Yun, Dae Hee;Lee, Chang Uk;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.9
    • /
    • pp.15-28
    • /
    • 2019
  • Long-term allowable compressive Loads of PHC piles were analyzed based on qualification tests results by 17 small and medium PHC pile producing companies and product specifications by 6 major and 17 small and medium PHC pile producing companies. At the present stage, an average long-term allowable compressive load of PHC pile was designed at 70% level from current design data, and safety factor of 4.0 was applied to long-term allowable compressive loads of PHC pile despite of its excellent quality. Most quality standards of PHC pile are specified at KS F 4306. But compressive strength test method of spun concrete is specified at KS F 2454. As a result of analyzing quality test data supplied by each manufacturer, all quality test results showed higher performances than standard values. Therefore, it was considered that the capacity of PHC pile can be used up to the maximum allowable compressive load of PHC pile when PHC pile is designed.

A Study on the Influence of Test Temperature & Cooling Fan Condition on the Fuel Test of Diesel Vehicle (디젤차량 연비시험에 있어 시험온도 및 냉각팬 조건이 미치는 영향분석에 관한 연구)

  • Kim, Hyun-Jin;Kim, Sung-Woo;Lim, Jae-Hyuk;Noh, Kyung-ha;Lee, Jung-Cheon;Kim, Ki-Ho;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.46-55
    • /
    • 2017
  • Due to the arise of natural disasters caused by global warming, consumers have more interest in the fuel efficiency of their vehicles, and fuel efficiency became an important factor in comparing vehicles. In this market situation, methods to measure fuel efficiency has become one of the main interests of vehicle related organizations and laboratories, and the current method to measure fuel efficiency is to follow the notification established by the ministry of trade, industry and energy, ministry of environment, and the ministry of land, infrastructure and transport. In this study, we analyze the influence of vehicle fuel efficiency according to test temperature and cooling fan condition which have the possibility to cause difference in fuel efficiency. The analysis results of the influence of the fuel efficiency according to the test temperature, the difference of the fuel efficiency of the test temperature ($21{\sim}29^{\circ}C$) within the allowable range of the notification showed a maximum difference of 2.9%. Therefore, it is necessary to consider the introduction of a test method that permits only the temperature change based on the reference point as the allowable range even in the test within the allowable range. The analysis of the influence of the fuel efficiency according to the cooling method showed no significant effect, and it seems reasonable to maintain the test method of the current notification.

A Study on the Performance Standard of Surveying Equipments for Cadastral Re-survey Project (지적재조사사업 측량 장비의 성능 기준 연구)

  • Hong, Sung-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3470-3476
    • /
    • 2012
  • In this study, for cadastral surveying specified in current relevant legislation, regulations of allowable error tolerance and applicable equipments, accuracy in the relevant regulations and applicable regulations were comprehensively studied. Based on them, the objective was to develop performance standard for cadastral surveying equipments satisfying allowable error tolerance of cadastral surveying specified in the special law for cadastral re-survey. The study results are as follows. By comparing current legislation for performance and allowable error tolerance of applicable equipments with provisions of the special law for cadastral re-survey, analyzed were where performance of equipments needs to be improved on cadastral re-survey project. Based on them, as primary control point surveying and detail surveying were separated, performance standard of equipments were presented. Results of this study may be utilized as basic materials for supply and demand program of surveying equipments on establishment of the basic plan for cadastral re-survey project.

Evaluation of Static Strength and Fatigue Strength for Bogie of a Korea High Speed Train Including Eddy Current Brake System (와전류 제동장치를 포함한 한국형 고속전철 대차의 정적강도 및 피로강도 평가)

  • 노규석;이상록;강재윤
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.267-272
    • /
    • 2001
  • A FEM-based analytical approach was used to evaluate the static strength and the fatigue strength of a KHST bogie including eddy current brake system. Calculation was carried out in the fields of linearity and small deformation. The yield strengths were used as criteria for evaluating the static strength and the fatigue limits were used as criteria for evaluating the fatigue strength. The analysis results show that there is not any location that exceeds the allowable criteria.

  • PDF

Calculation methods for the rail potential rise and the stray current in the ungrounded DC traction system (비접지 급전시스템에서의 레일전위상승과 누설전류 계산)

  • Chung, Sang-Gi;Park, Hyun-Joon;Kwon, Sam-Young;Bai, Chang-Han
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.631-635
    • /
    • 2006
  • DC traction power system is operated ungrounded to minimize the stray current. This causes rail potential increase and makes hazardous condition to the person in touch with running rails. To prevent the hazardous condition, maximum allowable limits on rail potential rise are set by regulations in advanced foreign countries. In this paper, the simplified calculation methods for the rail potential rise and the stray currents are discussed.

  • PDF