유치원 교실에서 공기 중 박테리아와 곰팡이 발생에 영향을 미치는 요인 (Factors Influencing Airborne Concentration of Fungi, Bacteria and Gram Negative Bacteria in Kindergarten Classroom)

  • 박동욱;조경아;윤충식;한인영;박두용
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.440-448
    • /
    • 2004
  • Airborne bacteria, gram negative bacteria (GNB) and fungi were measured in 70 class of 17 kindergartens. The objective of this study is to identify the factors influencing airborne concentrations of bacteria, GNB and fungi using multiple regression analysis. The average concentrations of bacteria and fungi exceeded $1,000\;CFU/m^3$. The average of GNB was $3.7{\times}10^2\;CFU/m^3$. This results indicated that air of kindergartens was contaminated with microbes such as bacteria and fungi. ANOVA test found that the concentrations of bacteria, GNB and fungi were significantly different by the characteristics of weather (rain, after rain, sunny) sampling date (July, August, September and October), the location of sampling site (ground level and basement) and the location of toilet (inside class, nearby class and away class). Multiple regression tests concluded that sampling date, the scale of city where kindergartens are located, the location of sampling site and ventilation efficiency can significantly affect the airborne concentration of bacteria, GNB and fungi. Most of these factors could be related moisture. Environmental factors that can cause the increment of moisture should be controlled in order to reduce airborne concentration of bacteria, GNB and fungi. Legal actions concerning prohibition on the presence of toilet inside class and ventilation criteria should be taken.

A Study on Concentration, Identification, and Reduction of Airborne Microorganisms in the Military Working Dog Clinic

  • Kim, Min-Ho;Baek, Ki-Ook;Park, Gyeong-Gook;Jang, Je-Youn;Lee, Jin-Hong
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.517-525
    • /
    • 2020
  • Background: The study was planned to show the status of indoor microorganisms and the status of the reduction device in the military dog clinic. Methods: Airborne microbes were analyzed according to the number of daily patient canines. For identification of bacteria, sampled bacteria was identified using VITEK®2 and molecular method. The status of indoor microorganisms according to the operation of the ventilation system was analyzed. Results: Airborne bacteria and fungi concentrations were 1000.6 ± 800.7 CFU/m3 and 324.7 ± 245.8 CFU/m3. In the analysis using automated identification system, based on fluorescence biochemical test, VITEK®2, mainly human pathogenic bacteria were identified. The three most frequently isolated genera were Kocuria (26.6%), Staphylococcus (24.48%), and Granulicatella (12.7%). The results analyzed by molecular method were detected in the order of Kocuria (22.6%), followed by Macrococcus (18.1%), Glutamicibacter (11.1%), and so on. When the ventilation system was operated appropriately, the airborne bacteria and fungi level were significantly decreased. Conclusion: Airborne bacteria in the clinic tend to increase with the number of canines. Human pathogenic bacteria were mainly detected in VITEK®2, and relatively various bacteria were detected in molecular analysis. A decrease in the level of bacteria and fungi was observed with proper operation of the ventilation system.

휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 - (A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations)

  • 김종규;박정영;김중순
    • 한국환경보건학회지
    • /
    • 제38권2호
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Validation of a simple binary scoring system for assessment of welfare measures of 10-day-old commercial broilers and their correlation with environmental parameters

  • Kumari, Priyanka;Choi, Hong-Lim;Metali, Shamira Hazi;Yussof, Siti Anisah Hazi;Han, Jiwoon
    • Journal of Animal Science and Technology
    • /
    • 제57권3호
    • /
    • pp.9.1-9.5
    • /
    • 2015
  • Background: A simple binary scoring system (SBSS) was developed and used to assess the welfare measures of commercial broiler chickens in South Korea. We also correlated welfare measures with environmental parameters of broiler house. Our measures of welfare included lameness, hock burn (HB) and foot pad dermatitis (FPD), whilst environmental parameters included air temperature, relative humidity, air speed, light intensity, air quality (in particular carbon dioxide ($CO_2$) and ammonia ($NH_3$) concentrations) and airborne microbes. Results: The effect of environmental parameters on welfare measures was apparent even on 10-day-old broilers. A non-parametric correlation analysis revealed significant correlations between environmental parameters and welfare measures. The key environmental parameters were relative humidity and light intensity. The results indicate that there is a need for proper control of environmental conditions on poultry farms, which could reduce health problems and subsequently reduce disease and mortality. Conclusions: In conclusion, the simplicity of SBSS makes it preferable over more complex scoring systems and allows a farmer to more easily assess the welfare measures on their own farm.

식품제조공장 내 공중부유미생물 오염도와 오염진균동정 (Identification and Concentration of Airborne Microbes in Food Manufacturing Plants)

  • 곽현정;이헌준;이상호;나혜진
    • 한국식품위생안전성학회지
    • /
    • 제26권4호
    • /
    • pp.361-365
    • /
    • 2011
  • To evaluate the indoor air quality of food manufacturing plants, the presence of viable bacteria and fungi was assessed in the indoor air of the facilities at which 9 food items were manufactured. Air samples were collected from the general zone, low clean zone and clean zone of each factory with an air sampler, in combination with plate counts agar using for bacteria, and dichloran-glycerol agar for fungi. The samples were incubated at $25^{\circ}C$ for 4 to 7 days. After culture, the colony forming units (CFU) on each plate were counted and corrected with a positive hole conversion table. The average concentration of bacteria was $2.2{\times}10^3\;CFU/m^3$ in the general zone, $1.2{\times}10^3\;CFU/m^3$ in the low clean zone and $7.3{\times}10^2\;CFU/m^3$ in the clean zone. The average concentration of fungal microbes was $2.5{\times}10^3\;CFU/m^3$ in the general zone, $2.6{\times}10^3\;CFU/m^3$ in the low clean zone, and $2.0{\times}10^2\;CFU/m^3$ in the clean zone. No meaningful differences were detected between the general zone and the low clean zone, but the clean zone had significantly lower concentrations than the other zones. Additionally, the identification of the fungi was performed according to morphological method using a giant culture and slide culture. The fungi were identified as belonging to 18 genera, and the genera Cladosporium(33%), Penicillium(29%) and Aspergillus(26%), predominated. Aspergillus isolates were identified to species level, and A. ochraceus, a mycotoxigenic species, was identified. As part of the effort to control the quality of the indoor air of food manufacturing plants, our results show that continued studies are clearly warranted.

Changes in the Microbial Distribution of Buyeo Royal Tombs: Tomb No. 1

  • Lee, Hyun Ju;Chung, Yong Jae
    • 보존과학회지
    • /
    • 제38권4호
    • /
    • pp.254-264
    • /
    • 2022
  • Built in the 6th and 7th centuries during the Baekje period, the Buyeo Royal Tombs consist of seven tombs, including Tomb No. 1, which contains murals. To preserve Tomb No. 1 from damage caused by microorganisms, periodic microbial-distribution investigations are conducted. Following such investigations in August 2016, June 2018, and November 2019, the microbes were classified according to the investigation period, location of collection, and space. This study compares and analyzes the results. The concentration of airborne microorganisms in Tomb No. 1 and the number of microbial genera identified in each space of the tomb decreased as proximity to the main room with murals diminished. During the investigation period, the genera Bacillus, Cladosporium, Penicillium, and Streptomyces were commonly identified on Tomb No. 1. The microorganisms collected from the main room walls were mostly isolated from the east and west walls where the genera Bacillus, Cupriavidus, Paenibacillus, Pseudomonas, and Streptomyces were commonly identified in three or more walls. In particular, the genus Streptomyces is a dangerous strain capable of damaging murals by penetrating into and discoloring the pigments on them. The data generated from this study may be useful for future research on microbial distribution in other domestic mural tombs and those located in North Korea and abroad.

병원내 공기중 미생물의 농도에 관한 조사연구 (An Investigation on Concentration of Airborne Microbes in a Hospital)

  • 최종태;김윤신
    • 한국환경보건학회지
    • /
    • 제19권1호
    • /
    • pp.30-36
    • /
    • 1993
  • A survey was conducted to measure concentration of airborne microbe in a hospital using RSC air sampler during October~November 1991.The result was as follows: 1) In an agar strip GK-A media for total counts of microbial particles. The highest count were 1384 CFU/m$^3$ in the main lobby, followed by 912 CFU/m$^3$, in the obstetric room, 688 CFU/m$^3$ in 1CU. By gram staining, the distribution for organisms in the air were shown 74.1% in gram possitive cocci followed by 16.8%, in gram possitive bacilli 6.7% in gram negative bacilli and 4.7% in yeast, but low organism was detected in recovery room with 194 CFU/m$^3$. 2) In agar strip S media for Staphylococci the count at the main lobby was detected in the recovery room with 92 CFU/m$^3$, Tests of coagulase were negative Staphylococci with 78%, and positive Staphylococci with 22%. The Staphylococci were highly resistance to penicillin, ampicillin and sensitive to amikacin, cefazolin, gentamycin and chloramphenicol. 3) In agar strip C media for coliform bacteria the colony counts at the main lobby was 139 CFU/m$^3$ and treatment room was 190 CFU/m$^3$, most frequently isolated microorganisms were non fermentative bacilli. 4) In agar strip HS media for yeast and molds. Most frequently colony counts 17~76 CFU/m$^3$, 0.5% lactophenol cotton blue stains were shown unidentified 77.2%, 8.1%, in Penicillium 8.1% in Aspergillus, and 3.8% in mucor.

  • PDF

동산문화재 다량 보관처의 공기 중 부유 미생물 분포 조사 (A Survey for Distribution of Airborne Microorganisms in Storage of Movable Cultural Properties)

  • 홍진영;서민석;김수지;김영희;조창욱;이정민
    • 보존과학연구
    • /
    • 통권36호
    • /
    • pp.64-73
    • /
    • 2015
  • 동산문화재 보관처는 사찰과 문중 또는 개인 소유자가 관리하므로 전문적이고 체계적인 보존 관리가 부족하며 이로 인해 열악한 보존환경으로 이어질 수 있다. 실내 공기질에 부유하는 먼지와 미생물은 문화재에 생물학적 훼손을 발생시킨다. 본 연구에서는 다양한 동산문화재들이 보관되어 있는 10곳의 수장시설 또는 전시 및 보관시설에 대하여 실내 공기 중 부유 미생물의 분포 상태를 조사하였다. 그 결과, 수집된 미생물의 집락수는 조사 장소에 따라 큰 차이를 나타냈는데, 가장 미생물 오염이 심각했던 보관처는 전남 영암의 D 유물전시관으로 이곳은 모든 조사 지점에서 $2,000C.F.U/m^3$ 이상이 검출되었으며 대부분의 소장처에서는 $166C.F.U/m^3$ 이상의 진균이 부유하고 있는 것으로 확인되었다. 검출된 미생물을 동정한 결과, Aspergillus sp.와 Penicillium sp., Alternaria sp. Cladosporium sp.등이 공통적으로 확인되었으며 Ceriporia lacerata, Ganoderma carnosum, Myrothecium gramineum 와 Bjerkandera sp. 등과 같은 부후균도 동정되었다. 이러한 진균들은 문화재의 원형 손상 등의 문제를 발생시킬 수 있으므로 부유 진균 농도에 대한 권고기준을 제시하고 소장처의 보존환경 관리 시스템을 마련해야할 것으로 판단된다.

  • PDF

A Survey on the Sanitary Condition of Kitchens of School Lunch Program

  • Kim, Jong-Gyu
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.174-176
    • /
    • 2003
  • A survey was conducted to investigate the sanitary condition of school kitchens in one region of Korea. A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools for food, sanitation and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during food preparation, processing and service. The inspection results showed their sanitary condition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4∼22.4$^{\circ}C$, and the range of relative humidity was 62.4∼69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22.5 to 26.5 CFU/15 min. These results indicate that the levels of sanitary condition of kitchens in the schools were not satisfactory for safe foodservice although the inspection showed good results. This study suggests that the school kitchens should be monitored and strict inspection is necessary.

  • PDF

병실 낙하균 및 산모감염에 관한 연구 (A Study on the Air Counts and the Infection of Maternity in n General Hospital)

  • 이남희
    • 대한간호학회지
    • /
    • 제9권2호
    • /
    • pp.17-26
    • /
    • 1979
  • This research is to prevent the infection of maternity in the hospital by examining the microbes contaminations in maternity through airbone microbes and those who are engaged in the ward of O.B. & G.Y. and to furnish the basic data available to hospital management. The bacterial growth of airbone microbes contaminations in nosocomial air and who thor the nasal cavity of passers by (doctors, nurses, parturient women) who went to the ward of O.B. & G.Y. contaminated or not were examined in“E”Univ. Hospital from July to August, 1979 by using thioglycollate broths and agar plates. The following results were obtained: 1. The average colony number of airborne microbes revealed as follows the pediatric ward (36 colonies), the internal ward (33 colonies), the ward of O.B. & G.Y. (30 colonies), the ward of surgery (24 colonies), delivery-waiting room (11 colonies), and the delivery room (3 colonies). 2. The bacterial growth beforenoon differed from that of afternoon. Namely, the latter (24 colonies) was higher than the former (21 colonies). 3. The type of strains isolated from the air of the ward revealed staphylococci (82%), Gram negative bacilli (18%), fungi (17%), Gram positive diplococci (13%), and Bacillus subtilis (2.8%). 4. The strains isolated in the delivery-waiting room revealed staphylococci (66.7%), Gram negative bacilli (33.6%), and revealed staphylococci (75%), Gram positive diplococci (8.3%), and fungi (8.3%), in delivery room. 5. Most of strains isolated in the ward of O.B. & G.Y. revealed staphylococci (100.0%), Gram positive diplococci (8.3%), and Gram negative bacilli (6.7%). 6. The strain isolated in the surgical ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), Gram negative bacilli (25%) and Bacillus subtilis (8.3%). 7. The strain isolated in the pediatric ward revealed staphylococci (75%), fungi (25%), Gram positive diplococci (8.3%), Bacillus subtilis (8.3%), and Gram negative bacilli (8.3%). 8. The strain isolated in the internal ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), and negative bacilli (16.7%). The strains isolated from the nasal cavity of those doctors and nurses who and enaged in the ward of O.B. & G.Y. revealed staphylococci (80%), Bacillus subtilis (10%), and Gram negative bacilli (10%), from doctors and Gram positive diplococci (10%), instead of Gram negative bacilli (10%), from nurses. 10. The strain isolated from nasal cavity of parturient women on admission revealed staphylococci (90%), and Gram negative bacilli (10%), but after admission revealed staphylococci (70%), Gram positive diplococci (10%), and Gram negative bacilli (10%). 11. Of the total 91 staphylococci isolated from the air of the ward, the Coagulase pastive was 36 (39.6%), and the negative 55 (60.4%), As a result of the coagulase experiment of the staphylococci isolated from the nasal cavity of those who are engaged in the ward of O.B. & G.Y. all were revealed as negative that belonged to non-pathogenic. 12. Consequence of the biochemic examination of the gram negative bacilli isolated from the air of the ward the aerobacter aerogens revealed was (16.7%) E-coli 5% in the nasal cavity of those came and went to the of O.B. & G.Y. and Aerobacter aerogens 7.5%.

  • PDF