• Title/Summary/Keyword: air-water

Search Result 6,827, Processing Time 0.033 seconds

A Numerical Simulation of Air-Cooled Ammonia/Water GAX Absorption Cooling Cycle (공냉형 암모니아/물 GAX 흡수식 냉동 사이클의 수치 해석)

  • Jeong, S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.488-500
    • /
    • 1995
  • An air-cooled ammonia/water GAX(Generator-Absorber heat eXchange) absorption cooling cycle is proposed and its performance is numerically evaluated. It is shown that the performance of the system is greatly dependent on the quality of the refrigerant leaving the evaporator. For any refrigerant concentration in the investigated range(99.1~99.9% ammonia), the cycle COP(coefficient of performance) reaches the highest value, when some amount(about 7%) of refrigerant evaporates in the refrigerant heat exchanger. Among temperature differences in various heat exchangers, the temperature difference between GAX-absorber and the GAX-generator shows the greatest effect on the system performance, whereas pressure losses cause no significant decrease in COP. The system COP increases almost linearly with increasing evaporator temperature, decreasing absorber temperature or decreasing condenser temperature. If both absorber and condenser temperature increase simultaneously, the decrease in the COP becomes larger.

  • PDF

An Experimental Study on the Supplemental Cooling and Heating Performance Using 1 kW Thermoelectric Module for Vehicle (열전모듈을 이용한 자동차용 1 kW급 보조 냉난방 시스템의 성능에 관한 실험적 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.224-230
    • /
    • 2014
  • The purpose of this paper is to investigate the performance of supplemental cooling and heating system equipped with the 1 kW thermoelectric module. The system consist of 96 thermoelectric modules, heat sink with louver fin and water cooling jacket which is attached on the hot side of the thermoelectric module. The cooling and heating performance test of the thermoelectric system is conducted with various conditions, such as intake voltage, air inlet temperature, air flow volume, water inlet temperature and water flow rate at calorimeter chamber in consideration of environmental conditions in realistic vehicle drive. The experimental results of a thermoelectric system shows that the cooling capacity and COP is 1.03 kW, and 1.0, and heating capacity and COP is 1.53 kW, and 1.5 respectively.

A Study on Applicability of Air-lift Pump for Deep Seawater pumping (해양심층수 취수를 위한 기포펌프의 적용성 연구)

  • Shin P. K.;Kim H J.;Hong S. W.;Choin H S.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Deep sea water has mid temperature, abundant nutrients and minerals, and good tooter quality. For the purpose of drawing up deep sea water without pump pit construction, tile authors are considering to use air-lift pump. This report describes fundamental experimental investigation for air-lift pump characteristic and improvement in efficiency.

  • PDF

An Experimental Study on the Dynamic Behavior of a Marine Riser (석유 시추보호관의 운동특성에 관한 실험적 고찰)

  • 김용철;이판묵;홍사영
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.46-58
    • /
    • 1988
  • The experimental investigations on the motion characteristics of a marine riser both in air and water were performed. The static deflections and natural frequencies of the riser in air including the effect of static offset, were obtained from the experiment. These results were compared with those of theoretical prediction by using a simple asymptotic formula. In order to investigate the nonlinear motion characteristics of the riser subject to nonlinear viscous drag and large displacement, the forced oscillation tests both in air and water were performed. In the forced oscillation tests in air, it was found that the transverse motion due to geometrical nonlinearity grows when the amplitude of in-line oscillation exceeds a certain critical value, say, order of 1-2 diameters. The planar motions of the riser in water due to vortex shedding and the geometrical nonlinearity were described. Some of these results were also compared with those of theoretical analysis, which uses a numerical perturbation technique based on the derived linear asymptotic solutions, and found to be generally in good agreement.

  • PDF

Influence of Moisture on Mold Growth in Building Materials (건축자재 내의 수분이 곰팡이 성장에 미치는 영향)

  • Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.852-857
    • /
    • 2012
  • Recently, the indoor air pollution by microbes such as fungi and mites have become a concern as important research topic on indoor air quality. Fungal growth is significantly affected by humidity. In this study, we examined the influence of relative humidity on the surface of building materials and the water content of building materials on the fungal growth rate by measuring the mycelium length of fungi in the fungal detector placed on the surface of building materials. As a result, even if the relative humidity on the surface of building materials is identical, the more water content of building materials is, the more fungi grow faster. It was suggested that fungal growth rate depends on not only the relative humidity on the surface of building materials but also the water content of building materials.

Electrical Properties of Both a Monolayer at the Air/Water Interface and a Langmuir-Blodgett Film Sandwiched Between Aluminum Electrodes (수면상의 고분자막과 알루미늄 전자간의 Langmuir-Blodgett막에 대한 전기적 특성)

  • Mitsumasa Iwamoto;Kang, Dou-Yol
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 1989
  • Electrical properties of both a monolayer at the air/water interface and Langmuir-Blodgett films sandwiched between aluminum electrodes are studied using a current-measuring technique. A change in induced charges on an electrode suspended in the air was measured in combination with the surface area isotherm in the electrical measurement of the monolayer. A change in induced charges on an electrode is measured while heating the sample in the electrical measurement of the LB films. From both measurements, we elucidated that a spontaneous polarization plays very important role in the electrical properties of both a monolayer at the air/water interface and LB films sandwiched between aluminum electrodes.

Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축)

  • Kim Dong-Seog;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2006
  • An effective technique of sludge separation is required for excess sludge of sewage or wastewater plant. The separation of bulking sludge of paper manufacturing plant was studied using DAF(Dissolved Air Flotation) system. The effects of parameters such as nozzle type, A/S(air/solid) ratio. pressure, injection time of pressured water and saturation time were examined. The results showed that the best nozzle type was flat which had small orifice hole, The optimum A/S ratio and pressure were $7.070\times10^{-3}$(recycle ratio of pressured water $20\%$) and 5atm, respectively. Injection times of pressurized water around 20-25 sesc and flotation time of 30 min appeared to be optimal for the DAF operation. The order of performance of packing was 18 mm > 22 mm > 32 mm.

Effect of Mixed Jet with Primary Nozzle Area Ratio of Ejector on Oxygen Transfer Characteristics (산소 전달 특성에 미치는 이젝터 구동 노즐 면적비에 따른 혼합 분류의 영향)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Journal of ILASS-Korea
    • /
    • v.27 no.3
    • /
    • pp.126-133
    • /
    • 2022
  • The objective of this is to experimentally investigate the effect of mixed jet on the oxygen transfer characteristics with the primary nozzle area ratio of an annular nozzle ejector for the application of a microbial fuel cell. A direct visualization method with a high speed camera system was used to capture the horizontal mixed jet images, and a binarization technique was used to analyze the images. The clean water unsteady state technique was used for the oxygen transfer measurement. The air-water mixed jet discharging into a water tank behaved similar to a buoyancy or horizontal jet with the primary nozzle area ratio. It was found that an optimum primary nozzle area ratio was observed where the oxygen transfer performance reached its maximum value due to the decrease of air volume fraction and the increase of jet length and air bubble dispersion.

An Experimental Study on the Melting of Horizontal Ice - Bar Located Concentrically in the Cylinder (수평원관속에 동심으로 놓여있는 얼음 봉의 융해현상에 관한 보험적 연구)

  • Lee, Dong-Wook;Yoo, Sang-Sin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.2
    • /
    • pp.196-203
    • /
    • 1986
  • The melting phenomena of horizontal cylindrical ice-bar immersed in water and air concentrically in the cylinder are experimentally investigated for the temperature range from $3.5^{\circ}C\;to\;2.5^{\circ}C$. The shapes of the melting ice-bar are recorded photographically by the shadowgraph method. The shadowgraphs of the melting ice-bar show that water adjacent to the bar flows upward for the temperature range from $3.5^{\circ}C\;to\;5.8^{\circ}C$ while above $5.8^|\circ}C$ the flow is downward direction. The local and average Nusselt numbers are obtoined with the recorded shadowgraphs and comparator. Melting shapes of the ice-bar in the air show the vortex motion in the bottom portion of the bar, whereas no vortex motion appears in the bottom portion when the bar is melted in the water.

  • PDF

Comparative Risk Analysis for Priority Ranking of Environmental Problems (환경 문제의 우선 순위 도출을 위한 비교 위해도 분석에 관한 연구)

  • 김예신;임영욱;남정모;장재연;이동수;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.285-298
    • /
    • 2002
  • In Korea, no CRA (comparative risk analysis) studies have been undertaken, nor have their methodologies of such studies been established. Therefore, the objectives of this study were to establish the framework of CRA consisting of health risk, economic risk and perceived risk, and to estimate and compare these risks among the three environmental problems of air pollution, indoor air pollution and drinking water contamination, which are themselves subject to the eight sub -problems of hazardous air pollutants (HAPs), regulated pollutants (representative as PM 10) and dioxins (PCDDs/PCDFs) in air pollution, indoor air pollutants (IAPs) and radon in indoor air pollution, and drinking water pollutants (DWPs), disinfection by -products (DBPs) and radionuclides in drinking water contamination in Seoul, Korea. After which, the priorities of these problems were set by individual and integrated risk. From the results, the rankings of both health risk and economical risk were in the following order: radon, PM10, IAPs, HAPs, DWPs, dioxins, DBPs, and radionuclides among the eight sub problems. On the contrary, the ranking of perceived risk was in the following order: HAPs, dioxins, radionuclides, PM10, DWPs, IAPs, Radon and then DBPs among the eight sub-problems.