• 제목/요약/키워드: air-water

검색결과 6,838건 처리시간 0.045초

블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성 (Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding)

  • 김기훈;황인성;나운;임주혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

사이펀 여수로 공기혼입장치(air slot)의 방류량 조절 능력에 대한 실험 연구 (Experimental Study for Capability of Air Slot in Siphon Spillway to Control Outflow Discharge)

  • 정재상;장은철;이창훈
    • 대한토목학회논문집
    • /
    • 제39권6호
    • /
    • pp.703-712
    • /
    • 2019
  • 본 연구에서는 수리모형실험을 통해 사이펀 여수로에 장착된 공기혼입장치(air slot)의 방류량 조절 능력을 검토하였다. 공기혼입장치의 단면 형상으로 원호 및 직사각형 형상을 채택하였으며, 개구부 면적을 조절할 수 있게 하였다. 공기혼입장치가 장착된 경우 사이펀 관 내부에 공기와 물이 혼합된 복잡한 흐름이 발생하였다. 공기혼입장치가 장착된 사이펀 여수로에서 저수지 내측 수위가 상승할 때와 하강할 때 동일한 수위에서 동일한 유량이 계측되었다. 공기혼입장치의 무차원 개구부 면적이 증가할수록 일정한 수두차 및 저수지 수위 조건에서 무차원 방류량은 감소하였다. 수리모형실험 결과는 공기혼입장치의 면적 조절을 통해 사이펀을 통한 방류량 조절이 가능함을 보여주었다.

한반도 연안 기온자료의 분포함수 추정 (Estimation on the Distribution Function for Coastal Air Temperature Data in Korean Coasts)

  • 정신택;조홍연;고동휘;황재동
    • 한국해안·해양공학회논문집
    • /
    • 제26권5호
    • /
    • pp.278-284
    • /
    • 2014
  • 연안 생태환경변화의 주요 지표로 이용되는 수온은 기온과 밀접한 상관관계가 있기 때문에 기온자료를 이용하여 기후변화에 따른 수온변화와 연안 생태환경변화를 추정할 수 있다. 기후변화는 기온 및 수온의 발생빈도 변화와 연안의 생태환경변화를 유발하기 때문에 기온과 수온의 발생 빈도분포 함수를 추정하는 연구가 필요하다. 본 연구에서는 우리나라 연안의 장기 기온자료를 이용하여 빈도분포함수를 추정하였다. 빈도분포 함수는 조위 분포함수 추정(Cho et al., 2003), 수온 분포함수 추정(Jeong et al., 2013) 등에 사용된 Bi-modal 형태의 분포함수를 이용 하였으며, 분포함수의 매개변수는 최소자승법으로 최적 추정하였다. 최적 추정된 매개변수는 기온자료의 기본적인 통계정보에 해당하는 평균, 표준편차, 왜도계수와 강한 상관관계를 보이고 있는 것으로 파악되었으며, 통계정보를 이용한 매개변수 추정공식의 RMS 오차는 5% 정도로 파악되었다. 한편 본 연구에서 제시하는 Bi-modal 분포함수는 전체적인 기온 분포양상을 적절하게 표현하고 있으나, 고온 영역의 급격한 빈도감소 양상 및 관측 자료의 분포에서 보이는 작은 첨두 재현에는 한계가 있는 것으로 파악되었다.

라돈방사능농도의 측정을 통한 지진발생 예측에 관한 연구 (A Study of the Prediction of Earthquake Occurrence by Detecting Radon Radioactivity)

  • 김윤신;이철민;이승일
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.677-688
    • /
    • 2003
  • The purpose of this study was to predict occurrence of earthquakes in Korea by measuring the concentration of radon radioactivity in the air and in the underground water. Two monitoring systems of radon concentration detection in the air were installed in Seoul, East Coast area, whereas of radon concentration in the underground water in Kyungju area during December, 1999 to June, 2001. The distribution of radon concentration in the air in Seoul is as follows Winter(10.10 $\pm$ 2.81 Bq/㎥), autumn(8.41 $\pm$ 1.35 Bq/㎥), summer(5.83 $\pm$ 0.05 Bq/㎥) and spring (5.34 $\pm$ 0.44 Bq/㎥), whereas the distribution of radon in the air in the East Coast area showed some difference as follows : autumn (14.08 $\pm$ 5.75 Bq/㎥), Summer (12.04 $\pm$ 0.53 Bq/㎥), Winter (12.02 $\pm$ 1.40 Bq/㎥) and spring (8.93 $\pm$ 0.91 Bq/㎥). In the meanwhile, the distribution of radon in the water is as follows : spring (123.59 $\pm$ 16.36count/10min), Winter (93.95 $\pm$ 79.69counter/10min), autumn (68.96 $\pm$ 37.53counter/10min) and spring (34.45 $\pm$ 9.69counter/10min). The daily range of the density of radon concentration in Seoul and East Coast area was between 5.51 Bq/㎥ - 9.44 Bq/㎥, 7.15 Bq/㎥ - 15.27 Bq/㎥, respectively. Correlation of the distributions of radon concentrations in the air and in underground water with earthquake showed considerable variations of radon concentration before the occurrence of the earthquake. The results suggested that radon radioactivity seemed to be helpful for the prediction of the occurrence of earthquake.

춘천의 안개발생과 관련된 기상특성분석 및 수치모의 (Analysis of Meteorological Features and Prediction Probability Associated with the Fog Occurrence at Chuncheon)

  • 이화운;이귀옥;백승주;김동혁
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.303-313
    • /
    • 2005
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years $(2000\~2003)$ data at Chuncheon and the probability of prediction is investigated. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for $2\~4$ hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1m/s. Especially, about $42\%$ of foggy day fell on the calm $(0\~0.2\;ms^{-1})$ conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water surface temperature was calculated by using Water Quality River Reservoir System (WQRRS) and then it was used as the surface boundary condition of MM5. The numerical experiment was carried out for 2 days from 1300 LST on 14 October 2003 to 1300 LST on 16 October 2003 and fog was simulated at dawn on 15 and 16 October 2003. Simulated air temperature and dew point temperature indicate the similar tendency to observation and the simulated difference between air temperature and dew point temperature has also the similar tendency within $2^{\circ}C$. Thus, the occurrence of fog is well simulated in the terms of the difference between air temperature and dew point temperature. Horizontal distribution of the difference between air temperature and dew point temperature from the numerical experiment indicates occurrence, dissipation and lasting time of fog at Chuncheon. In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

잔류공기조건에 따른 관 내 유동의 압력변화에 관한 실험적 연구 (An Experimental Study of Pressure Variation in Pipe Flow according to Residual Air Condition)

  • 박재곤;이경수;고주석;류시완
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.113-119
    • /
    • 2022
  • Sudden intrusion of a large amount of surface water into a flood defensive tunnel or pipeline system can compress the residual air. The compressed air may explode along with water through the inlet or air vent, resulting in hydraulic capacity degradation or safety hazards. This study aims to investigate the behavior of compressed air body in pipelines according to the residual air condition with a series of laboratory experiments measuring pressure variation. It has been found that flow characteristics and residual air conditions have a dominant influence on the magnitude and periodicity of the pressure variation. A proper measure to effectively control the residual air is required for securing the design capacity of flood defensive pipeline systems, since the peak pressure is predominantly affected by residual air conditions.

Modal analysis of perforated rectangular plates in contact with water

  • Jeong, Kyeong-Hoon;Ahn, Byung-Ki;Lee, Seong-Cheol
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.189-200
    • /
    • 2001
  • This paper presents an experimental modal analysis of perforated rectangular plates in air or in contact with water. The penetration of holes in the plates had a triangular pattern with P/D (pitch to diameter) 2.125, 2.500, 3.000 and 3.750. The plate was clamped along the plate edges by a number of bolts and nuts. The natural frequencies of the perforated plates in air were obtained by the analytical method based on the relation between the reference kinetic and maximum potential energies and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plates in air. Additionally, it was empirically found that the natural frequencies of the perforated plate in air increase with an increase of P/D, on the other hand, the natural frequencies of the perforated plate in contact with water decrease with an increase of P/D.

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

The Effect of Ambient Air Condition on Heat Transfer of Hot Steel Plate Cooled by an Impinging Water Jet

  • Lee, Pil-Jong;Park, Hae-Won;Lee, Sung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.740-750
    • /
    • 2003
  • It has been observed that the cooling capacity of an impinging water jet is affected by the seasonal conditions in large-scale steel manufacturing processes. To confirm this phenomenon, cooling experiments utilizing a hot steel plate cooled by a laminar jet were conducted for two initial ambient air temperatures (10$^{\circ}C$ and 40$^{\circ}C$) in a closed chamber, performing an inverse heat conduction method for quantitative comparison. This study reveals that the cooling capacity at an air temperature of 10$^{\circ}C$ is lower than the heat extracted at 40$^{\circ}C$. The amount of total extracted heat at 10$^{\circ}C$ is 15% less than at 40$^{\circ}C$ , These results Indicate the quantity of water vapor, absorbed until saturation, affects the mechanism of boiling heat transfer.

Flow Characteristics in Nappe Flow over Stepped Drop Structure

  • Kim, Jin Hong;Woo, Hyo Seop
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.54-61
    • /
    • 2004
  • This paper deals with flow characteristics on the air entrainment and the energy dissipation in nappe flow over the stepped drop structure. Nappe flow occurred at low flow rates and for relatively large step height Dominant flow features include an air pocket, a free-falling nappe impact and a subsequent hydraulic jump on the downstream step. Air entrainment occurred from the step edge, through a free-falling nappe impact and a hydraulic jump. Most energy was dissipated by nappe impact and in the downstream hydraulic jump. It was related with the step height and the overflow depth, but not related with step slope. The stepped drop structure was found to be effcient for water treatment and energy dissipation associated with substantial air entrainment.

  • PDF