• Title/Summary/Keyword: air-water

Search Result 6,838, Processing Time 0.037 seconds

The Study on the Humic Acid Removal using Underwater Plasma Discharge (수중 방전을 이용한 휴믹산 제거)

  • Hong, Eunjung;Chung, Paulgene;Ryu, Seungmin;Park, Junseuk;Yoo, Seungryul;Lho, Taihyeop
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.367-374
    • /
    • 2012
  • A flotation process has a shorter processing time and needs less space than a sedimentation process. Dissolved air flotation process (DAF) is an efficient flotation method and used in a conventional wastewater treatment process. However, DAF requires the circulation of water containing compressed air and requires expensive installation and operation cost. Plasma Air Flotation (PAF) process is able to float flocs by micro bubbles generated from underwater plasma without the circulation of bubbly water and additional saturators. Therefore, PAF can be an alternative solution overcoming economic barriers. In this study, Humic acid removal efficiency by PAF process was compared with that of sedimentation process. 44.67% and 87.3% reduction rate based on UV 254 absorbance has been measured in sedimentation and PAF respectively. In particular, PAF in the flocculation zone can dramatically remove humic acid from water. In flocculation zone, PAF can separate organic matters but sedimentation cannot.

Development of an Automatic Brown Rice Germinating System of Air-Phase Type with Intermittent Water Spraying and Anion Radiation (간헐 분무와 음이온 방사를 가진 공기노출형 자동 현미발아시스템의 개발)

  • Lim, Ki-Taek;Kim, Jang-Ho;Chung, Jong-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.187-194
    • /
    • 2011
  • In this study an automatic germinating system for germinated brown rice (GBR) was developed for accelerating germination and sprouting of brown rice. With the developed germinating system, the effects of anion radiation treatment on germination ratio, sprout growth, color quality and ${\gamma}$-aminobutyric acid (GABA) content of brown rice were investigated. This system can fast produce GBR by controlling the environmental conditions such as ambient temperature, relative humidity, and proper anion radiation. Air-phase germination with intermittent water spraying improved both germination ratio and sprout growth by about 2.2 and 2.3 times, respectively, compared to the conventional water soaking method. Our results strongly suggest that this germinating system that provides air-phase germination with intermittent water spraying and anion radiation can produce germinated brown rice with good color quality, high GABA content, and fast germination ratio as well as sprout growth.

AN EXPERIMENTAL STUDY ON AIR-WATER COUNTERCURRENT FLOW LIMITATION IN THE UPPER PLENUM WITH A MULTI-HOLE PLATE

  • NO HEE CHEON;LEE KYUNG-WON;SONG CHUL-HWA
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.557-564
    • /
    • 2005
  • Air-water countercurrent flow limitation at perforated plates with four holes was investigated in a vertical tank to see the effects of the plate thickness, the number of hole, and the diameter of the hole on the onset of CCFL. The thickness of plates was 1 cm and 4 cm, with a relatively large hole diameter of 5 cm. The collapsed water level formed on the perforated plate and its distribution in the upper plenum were measured. The gas flow rate in the multi-hole plate is relatively higher than one in the single tube because some of holes in the multi-hole plate provide a flow path fur liquid with less air-liquid resistance than in the single tube. The onset of CCFL occurred at nearly the same air flow rate regardless of the plate thickness. The negligible effect of the plate thickness on CCFL means that the flooding is initiated at the top of the plate rather than at its bottom. It turns out that $j_k$ and $K_k$ better fit the data than $H_k$ when hole diameter is greater than 2.86 cm. In our experimental ranges, the collapsed water levels at the onset of CCFL ranged from 7.5 cm to 10.5 cm. There was no three dimensional distribution of water level before and after the onset of CCFL.

Experimental Study on Heat Transfer and Pressure Drop of Heat Exchangers for Cooling Fan Coil Unit (냉방용 팬코일 유닛 열교환기의 열전달 및 압력강하 특성 실험연구)

  • Kwon, Young-Chul;Ko, Kuk-Won;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.599-604
    • /
    • 2008
  • An experimental study has been performed to investigate the air-side capacity and pressure drop of the fin-tube heat exchanger for a fan coil unit under a cooling condition. The experimental data of five kinds of slit fin-tube heat exchangers were measured using an air-enthalpy calorimeter and a constant temperature water bath. Cooling capacities at the air and water rating flow rates were larger at the lower inlet water temperature. With increasing the water flow rate, the cooling capacity increased at the constant rate. Under the lower inlet water temperature, since the condensate was generated more on the fin-tube surface, the air-side pressure drop of the heat exchanger was larger.

A STUDY ON THE AIR SCREEN IN WATER 1. Experiments on the Air Screen Effects for Driving and Intercepting Fish School (어업용 수중 기포막에 관한 연구 1. 기포막에 의한 어군의 차단 및 구집 실험)

  • PARK Jung-Heui
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.5 no.2
    • /
    • pp.50-56
    • /
    • 1972
  • This study has been carried out to observe the driving and the intercepting effects of air screen on some sea-water fishes ; Chrysophrys major, Mylio macrocephalus, Fugu pardalis. 1. By perforating fine holes on the compressed air pipes, air screen was formed in the water, and this screen was set at $45^{\circ}$, and $90^{\circ}$ against the fish passage to observe the reactions on the part of the fish. 2. Changes were given to the location of the air screen in the water to observe how the air screen drived the fish to its direction. 3. The effective distance between holes on the air piprs was determined by a series of experiments of setting up two air screens of various types in hole distance, by moving a screen to-ward the other, and of observing the distance between two screens when fish eseape through the space. The results of the above experiments observed as follows were : 1. The passage of fish was effectively intercepted by setting up the air screens at 45 degrees against the fish passage and it was also intercepted when the screen was set at 90 degrees against the passage. 2. Fish could be driven by moving the air screen toward the fish. 3. The air screen formed from the pipe above than 0.3mm in diameter was effective, but less than 0.2mm was not sufficiently effective. 4. The strength of the air pressure in the pipe should be higher than $0.087kg/cm^2$. 5. The fish holding ability to obtain effective air screen was ranged as following when the air pressure was $0.160kg/cm^2$. and the hole diameter was 0.3mm on the 12.6mm pipe, depending upon the intervals of the holes on the pipe: The shortest distance which could hold fish between two screens was 59.4cm when the holes were perforated at every 40cm; 33.5cm when at every 30cm; 28.75cm when at every 10cm: and 27.25cm when at every 5cm. Thus, no significant change was at served when the holes were perforated more densely than 30cm intervals. Therefor the hole intervals should be 30cm in designing fishing gear employing air screen.

  • PDF

Water and Air Movement in Bounded Layered Soil (다층토양에서의 물과 공기의 움직임)

  • 선우중호
    • Water for future
    • /
    • v.8 no.2
    • /
    • pp.56-60
    • /
    • 1975
  • Traditional descriptions of water movement in soils and of calculations of infiltration rates neglect the air movement and its compressibility. The movement of two fluids in the bounded layered porous medium is treated analytically and computer simulations are conducted for given boundary conditions and initial saturation profiles. The movement of a given saturation across the interface between the different soil layers is theoretically developed by considering the conservation of mass. It is shown that the existence of the interface affects the infiltration rate when the average total velocity is greater than zero. The transition from one layer to another layer cause a change in the capillary drive and consequently influences the infiltration rate.

  • PDF

Changes in the Physicochemical Properties and Functional Components of Uncooked Foods Treated with Electrolyzed Water

  • Jin, Tie-Van;Oh, Deog-Hwan;Eun, Jong-Bang
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.72-79
    • /
    • 2008
  • In this study, changes in the physicochemical properties and functional components of uncooked foods, including carrots, cabbage, shiitake (Lentinus edodes) and white button (Agaricus bisporus) mushrooms, sea mustard, and laver treated with electrolyzed water were investigated. No changes were observed in the primary compositions of any of the materials that were hot air- or freeze-dried after being treated with electrolyzed water. The lightness (L), redness (a), and yellowness (b) values of the carrots, shiitake, and laver were not affected by drying, while changes did occur in the cabbage (L-, a-, and b-values), mushrooms (a-value), and sea mustard (b-value) specimens that were hot air- or freeze-dried following the treatments with electrolyzed water. The dietary fiber contents of all the materials increased when they were hot air-dried. Vitamin C content decreased when the samples were treated with alkalic electrolyzed water. No changes occurred in the lectin, $\beta$-carotene, or total phenolic compound contents after the electrolyzed water treatments, suggesting that electrolyzed water could be used effectively as a pasteurization step for uncooked carrots, cabbage, shiitake and white button mushrooms, sea mustard, and laver.

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Experimental study on feasibility test for removing particles in air scouring membrane backwash water with metal membrane (금속막을 이용한 저압 막 공기병용 역세척수 처리 타당성 연구)

  • Park, No-Suk;Yoon, Sukmin;Moon, Yong-Taik;Lee, Sun-Ju;Park, Sunghyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.251-259
    • /
    • 2015
  • The main objective of this research is to study feasibility for applying metal membrane to remove particles from air scouring membrane backwash water. Also, the research was conducted to investigate the influence of polyamine coagulation on floc growth in membrane backwash water as pretreatment for removal particles. From the results of experiments for evaluating the influence of polyamine coagulation on floc growth, it was investigated that particles in the rage of $2{\sim}50{\mu}m$ grew up to $30{\sim}5,000{\mu}m$. In addition, all six metal membranes showed lower removal efficiency, which was 0.87~13.89%, in the case of no polyamine coagulant. On the other hand, in the case of injecting polyamine coagulant, those did extremely high efficiency in 56~92%. From the SEM(Scanning Electron Microscope) images of filtered wiremesh and metal foam membrane, sieve effects were predominant for liquid solid separation in wiremesh and adsorption and diffusion capture effects were predominant in metal foam membrane.