• Title/Summary/Keyword: air-particle flow

Search Result 394, Processing Time 0.032 seconds

Hydrodynamic Characteristics of Circulating Fluidized Bed Incinerator (순환유동층 소각로의 수력학적 특성에 관한 연구)

  • Byun, Y.C.;Park, S.H.;Hwang, J.H.;Kim, S.W.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.173-182
    • /
    • 1999
  • Internally Circulating Fluidized Bed Combustor(ICFBC) has been used for the incineration of waste sewage sludge. In this study hydrodynamic characteristics of two phase flow have been studied in a riser section of ICFBC. A lab-scale riser(l/5 scale of pilot plant) is designed and SiC (Geldart type B) is used for solid particles. Experiments are performed by controlling the fluidization parameters including superficial velocity, particle diameter and secondary air to primary air ratio for determination of solid holdup profiles in the riser. Our flow regime during experiments mainly belongs to the onset of turbulent regime(for d_{p}:300{\mu}m) and fast fluidization regime(for d_{p}:100{\mu}m). Superficial velocities of each regime are well agreed with results obtained by other researches. The results show that the axial solid holdup distributions calculated by measuring differential static pressures in the riser are found to show a basic profile described by a simple exponential function. As the particle size decreases, solid holdup along the riser is more uniformly distributed. To prove these experimental results, numerical calculations are being performed.

  • PDF

Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack (화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증)

  • Shin, Dongho;Kim, Young-Hoon;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Lee, Ga-Young;Chun, Sung-Nam;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

Flow and Performance Analysis of Atomizing Nozzle (아토마이징 노즐의 유동 및 성능해석)

  • Kim, Bong-Hwan;Ryu, Kwang-Hyun;Jung, Eun-Ik;Cho, Eun-Man;Lee, Jung-Eun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.3
    • /
    • pp.42-48
    • /
    • 2010
  • The aim of this study is to investigate the influence of driving atomizing nozzle position, the slope of sludge entering tube and supplying air flow rate on the performance of sludge air dryer. This paper deals with optimization of the geometry of the atomizing nozzle for sludge drying using computational fluid dynamics and drying performance test using pilot air dryer. The air drying system was composed of the atomizing nozzle which made high-speed fluid field. dewatered cake was crushed at the high-speed zone as the first step and formed intto dried powder of sphere shape by the collision between particles at the circling zone. The CFD analysis results show when the slope of entering sludge tube is smaller, suction air amount is increased. It is shown that the developed atomizing nozzle is very excellent in the drying performance through pilot test.

NOx Reduction by Acoustic Excitation on Coaxial Air Stream in Lifted Turbulent Hydrogen Non-Premixed Flame (부상된 수소난류확산화염에서 동축공기의 음향가진에 의한 NOx 저감)

  • Heo, Pil-Won;Oh, Jeong-Seog;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • The effects of acoustic excitation of coaxial air on mixing enhancement and reduction of nitrogen oxides (NOx) emission were investigated. A compression driver was attached to the coaxial air supply tube to impose excitation. Measurements of NOx emission with frequency sweeping were performed to observe the trend of NOx emission according to the fuel and air flow conditions and to inquire about the effective excitation frequency for reducing NOx. Then, Schlieren photographs were taken to visualize the flow field and to study the effect of excitation. In addition, phase-locked particle image velocimetry (PIV) was performed to acquire velocity field for each case and to investigate the effect of vortices more clearly. Direct photographs and OH chemiluminescence photographs were taken to study the variation of flame length and reaction zone. It was found that acoustic forcing frequencies close to the resonance frequencies of coaxial air supply tube could reduce NOx emission. This NOx reduction was influenced by mixing enhancement due to large-scale vortices formed by fluctuation of coaxial air jet velocity.

  • PDF

A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - I. Electrical Characteristics (전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-I. 전기적 특성)

  • 김용진;황태근;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.572-578
    • /
    • 2001
  • This study conducts a laboratory measurement on a cylindrical electrostatic precipitator(ESP) with a 30mm-diameter cylinder. Several kinds of test aerosols are generated with an atomizer and a diffusion dryer. The effects of applied voltage, flow state, gas velocity, and gas temperature on the electrical characteristics of the precipitator and onset of corona are experimentally investigated. The corona onset voltage is decreased, as diameter of discharge electrode wire becomes small or temperature of the precipitator increases. As the fluid velocity or particle load in the precipitator increases, the corona current is decreased.

  • PDF

A Study on the Kinematic Characteristics of the Ocean High Elevation Fountain (해상용 고사분수의 운동학적 특성 연구)

  • Lee, Choon-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.85-90
    • /
    • 2011
  • Recently, many high elevation fountain are constructed for the beauty of beach landscape. Typically, a fountain has several nozzles that shoots water upwards or at an angle into the air. But unfortunately, the weather and wind can cause the water soak nearby walkways and pedestrians. Therefore, in this study, a mathematical model of high elevation fountain is suggested to predict the actual travelling distance of water droplet by the wind. To simplify our treatment of the water flow and to avoid issues such as fluid dynamics and surface tension, we have adopted a particle model for the fountain water. The particles are assumed not to interact with each other, and do not deform during their flight through air.

A Basic Study on Fluidized Bed Heat Exchanger with Finned Tube (유동층형(流動層形) 핀관(管) 열교환기(熱交換器)의 열전달특성(熱傳達特性)에 관(關)한 기초적(基礎的) 연구(硏究))

  • Lee, S.W.;Yoo, J.O.;Yang, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.168-175
    • /
    • 1991
  • Experiments have been conducted to measure the overall heat transfer coefficient for gas-solid fluidized double pipe heat exchanger with finned tube. The average particle diameters of alumina are used in 0.4, 0.5, 0.6 and 0.9mm. And the effects of average particle diameter, static bed height and flow velocity on overall heat transfer coefficient have been investigated. Also the heat transfer effect of fluidized bed was compared with that of single phase forced convection and that of heat exchanger with smooth tube.

  • PDF

Nanoparticle Focusing with A Novel Converging-Diverging-Type Aerodynamic Lens (수축-발산형 공기역학렌즈를 이용한 초미세 나노 입자의 집속)

  • Lee, Kwang-Seung;Kim, Song-Kil;Lee, Dong-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.589-596
    • /
    • 2008
  • An orifice type of aerodynamic lens is generally used to focus nanoparticles. However, it is impossible to focus particles smaller than 10nm in air due to flow instability of fluid in a lens. In this study, we propose a new converging-diverging type of the aerodynamic lens capable of focusing particles of 5-50nm in air. Designing factors of the lens configurations is also extracted and explained in detail through a numerical simulation. It was demonstrated that the aerosols are delivered from the entrance to the downstream of the lens system with 90% transmission efficiency. The final beam diameters are shown to be more or less 1mm in the range of particle size.

Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector (사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구)

  • Hyun, Daegeun;Cha, Hyuksang
    • Particle and aerosol research
    • /
    • v.10 no.4
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

Heat Transfer in the Vertical Type Fluidized Bed Heat Exchanger with Corrugated Tubes (파형관을 갖는 수직형 순환유동층 열교환기의 열전달)

  • Ahn Soo Whan;Bae Sung Taek;Kim Myung Ho;Lee Byung-Chang;Lee Yoon Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1149-1155
    • /
    • 2004
  • An experimental study was performed to investigate the characteristics of heat transfer in a vertical type fluidized bed shell-and-tube type heat exchanger with corrugated tube. Seven different solid particles having the same volume were circulated in the heat of exchanger. The effects of various parameters such as water flow rates, particle geometries, materials, and corrugated tube geometries were investigated. The present work showed that the higher thermal capacities of materials and the geometries closer to the spherical one have higher heat transfer performances. In addition, heat transfer coefficients in the corrugated tubes were a little higher than those in the smooth tubes.