• Title/Summary/Keyword: air-facing surface

Search Result 21, Processing Time 0.021 seconds

A Study on Prediction of the Base Pressures for an Axi-Symmetric Body

  • Baik, Doo-Sung;Han, Young-Chool
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.10
    • /
    • pp.1423-1433
    • /
    • 2001
  • A flow modeling method has been developed to analyze the flow in the annular base (rear- facing surface) of a circular engine nacelle flying at subsonic speed but with a supersonic exhaust jet. Real values of exhaust gas properties and temperature at an altitude of 30, 000 feet are employed. Potential flows of the air and gas streams are computed for the flow past a separated wake. Then a viscous jet mixing is superimposed on this inviscid solution. Conserva- tion of mass, momentum and energy for the wake flow field is achieved by multiple iterations with modest computer requirements.

  • PDF

A Study on the Typological Characteristics of the Super High-Rise Housings in Hong Kong (홍콩 초고층 주거의 평면적 특징에 관한 연구)

  • Kim, Sung-Hwa;Lee, Jae-Hoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.43-48
    • /
    • 2004
  • The purpose of this study is to analyze the typological characteristics of super high-rise housings in Hong Kong. The results are as follows; 1) The Plan types of the residential building in Hong Kong are mostly tower types and they show lots of curves on the external resident blocks so each resident families can face maximum open air. 2)Household arrangements or resident families form are shown as symmetrical and systematic type of structures that centers around the core. 3)The core types are mostly central core types and a portion of central core is planned to place void and alight garden for improving the lighting and ventilating problems. 4)If we review our room arrangements, they are arranged from entrance kitchen, livingroom bedroom to bathroom to the end. Livingrooms and dinning rooms are normally formed together. 5)If external resident blocks are facing the open air, one of the surface is on view axis, kitchen or bathroom are symmetrically located on the other side which faces the units for the purpose of ventilating.

  • PDF

A Study at Investigating the Climate Change in East Asia with Changing Sea Surface Temperature

  • Park, Geun-Yeong;Lim, Yong-Jae
    • Journal of Integrative Natural Science
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • The unsustainable human activities like increased use of automobiles, heavy industrialization and the use of large volumes of fertilizers, chemicals and pesticides in the agricultural land cause climate change problems in one way or another. Under normal circumstances, the heat radiations from the sun will be reflected back. An excessive volume of GHGs in the atmosphere would prevent these radiations from reflecting back. East Asia is facing severe climate change issues in recent times. A lot of climate change problems such as hurricanes and floods have been reported from this region in the last couple of decades. The study aimed at investigating the climate change in East Asia with changing Sea Surface Temperature (SST). The study adopted a quantitative research method with a case study research design where a deliberate focus was made on the East Asia Region. Secondary data was gathered and analyzed to yield both descriptive and inferential statistics. The study concluded that the impact of East Asia Climate variability was significant mainly for some extreme events. Also, the study concluded that there was a significant link between the change of the East Asia climate variability and that of the sea surface temperature. Further, the study concluded that a linear relationship existed between the sea surface temperature and the climate of East Asia. Hence, a linear regression was a significant predictor of the East Asia Climate (EAC) based on changing sea surface temperature. The model revealed that 37.4% of the variations in the climate change index were explained by the changes in the sea surface temperature. The climate was expected to change with a value of 49.48 for a unit change in the sea surface temperature.

Emulsion Blends of Polyurethane Ionomers from Ester and Ether Type Polyols (Ester 및 Ether형 Polyurethane Ionomer의 Emulsion 블랜드)

  • Kim, Sang-June;Kim, Byung-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.614-619
    • /
    • 1992
  • Two types of polyurethane(PU) ionomer dispersion having different type of soft segment, viz. Poly (tetramethylene adipate) glycol(PTAd), and polypropylene glycol(PPG) were emulsion blended. Viscosity of emulsion blend, mechanical, and surface properties of the emulsion cast films were determined as a function of blend composition. Mechanical properties showed a large scatter of data or negative deviation from the additivity rule, and this was attributed to the incompatibility of soft segments. Contact angle measurement indicated that air facing surface of emulsion cast film contained more of PPG PU, due probably to its smaller particle diameter compared to PTAd PU.

  • PDF

Studies on the Environmental Factors for Sap Exudation of Acer mono and the Resource Development of its Community (2): Environmental Factors and Tree Recovery (고로쇠나무(Acer Mono)의 수액출수에 미치는 환경요인과 그 군락의 자원화에 관한 연구 (2): 환경요인 및 공시목의 회복)

  • Kim, Chul-Soo;Kwak, Ae-Kyung
    • The Korean Journal of Ecology
    • /
    • v.17 no.4
    • /
    • pp.533-545
    • /
    • 1994
  • The bleeding of 39 Acer mono trunks by wounding was investigated at the altitudes of 400m, 500m, 800m, and 1100m on Wangsirobong (1,214m), Mt. Chiri area (127°34'E., 35°14'N.) from February 4 to March 21, 1993 and from February 23 to March 23, 1994. The amount of sap in a day was clodely related to the change of air temperature and wind speed. Especially, the abundant sap was exudated at the ranges of -4~13℃ in the daily range of temperature and it was below 0.14m/s in wind speed. The most abundant bleeding was exudated from Acer mono trunk located south facing slope in 800m altitude. Also the amount of sap increased with incereasing suface area of crown. The maximum bleeding of sap was collected from the hole punctured at 80cm height from the ground surface at southern part of the trunks. And the number of exudation holes had an important effect on bleeding of sap but the number of holes should be controlled by DBH of trunks. These results suggested that the exudation was influenced by the daily range of temperature and wind speed. And the altitude, direction of sloped where the trees occurred, surface area of crown, the number of exudation holes, height form the ground surface and the direction of the hole was 91.6% when germicide (Dimethyl-4,4' -ophenylene bis 3-thio alonate) was treated from April to October after bleeding of sap in the year.

  • PDF

Fabrication of Co-Planar Type Single Chamber SOFC with Patterned Electrodes (패턴된 전극을 가진 표면 전도형 단실형 고체산화물 연료전지의 제조)

  • Ahn, Sung-Jin;Kim, Yong-Bum;Moon, Joo-Ho;Lee, Jong-Ho;Kim, Joo-Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.798-804
    • /
    • 2006
  • Co-planar type single chamber solid oxide fuel cell with patterned electrode on a surface of electrolyte has been fabricated by robo-dispensing method and microfluidic lithography. The cells were composed of NiO-GDC-Pd or NiO-SDC cermet anode, $(La_{0.7}Sr_{0.3})_{0.95}MnO_3$ cathode, and yttria stablized zirconia electrolyte. The cell performance at $900^{\circ}C$ was investigated as a function of electrode geometries, such as anode-to-cathode distance, numbers of electrode pairs. Relationship between OCV and I-V characteristics at the optimized operation condition was also studied by DC source meter under the mixed gas condition of methane, air, and nitrogen. An increase of anode-facing-cathode area leads to lower OCV due to intermixing between product gases of anode and cathode, which in turn decreases the oxygen partial pressure difference.

Comparison of Sound Transmission Loss of Panels Used in Ship Cabins for Field and Laboratory Measurements

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1E
    • /
    • pp.9-15
    • /
    • 2009
  • In this paper, FSTL (Field Sound Transmission Loss) measured in a mock-up simulating ship cabins is studied. A mock-up is built by using 6 mm steel plate, and two identical cabins are made where 25 mm or 50 mm sandwich panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where effects of wall and ceiling panel thickness, and presence of a unit toilet on FSTL are investigated. It is found that the effect of unit toilet on FSTL is at most 1 dB. From the comparison of FSTL for panels of the same thickness of 50 mm, it is observed that panel having inside air cavity of 10 mm shows higher STL than that of the panel without air cavity. Comparison of FSTL for panels of 50 mm and 25 mm thickness shows that dependency on surface density predicted by mass law is not observed. The sandwich panels act as a mass-spring system, which shows a resonant mode that cannot be explained by the mass law. It is also found that STL from laboratory test is higher than FSTL by 5- 10 dB, which can be explained by flanking structure-borne noise transmission path such as ceiling, floor and corridor-facing wall.

Magnetic Levitation Control through the Introduction of Bogie Pitch Motion into a Control Law (대차 피치운동을 반영한 흡인식 자기부상제어)

  • Ha, Chang-Wan;Kim, Chang-Hyun;Jo, Jeong-Min;Lim, JaeWon;Han, Hyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.2
    • /
    • pp.87-93
    • /
    • 2015
  • The uneven reaction surface profile facing the lift magnets in attractive Maglev vehicles naturally brings about pitch motion of the bogie. In particular, in the placement configuration of the long stator of the linear synchronous motor (LSM) on the track for high-speed propulsion, surface irregularities and the offsets between the stator packs create measurable airgaps, i.e., the clearance between the magnet and the stator, with discontinuously extreme values, resulting in bogie pitch motion. This occurs because the airgap velocities and accelerations derived by the differentiations of the measured air-gaps are used to determine the voltages applied to the magnets. This paper incorporates bogie pitch motion into a control law for each magnet controller to reduce the variations in both the airgap and the pitch angle. The effectiveness of the proposed method is analyzed using a full-scale Maglev vehicle running over a test track.

Surface Dose Evaluation According to the Environment Around the Patient after Nuclear Medicine Examination (핵의학 검사 후 환자의 주위 환경에 따른 표면 선량 평가)

  • Lee, Young-Hee;Park, Jae-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.943-948
    • /
    • 2021
  • The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18F by injecting 20 and 10 mCi respectively into the NEMA phantom, and then measuring the surface dose for 60 minutes by positioning the phantom at a height of 1 m above the surface, at a distance of 0, 5 and 10 cm from the wall, and at the same location as the phantom facing the wall. Each experiment was repeated five times for reproducibility of the experiment and one way analysis of variability (ANOVA) was performed for significance testing and Tukey was used as a post-test. The study found that surface doses of 220.268, 287.121, 243.957, and 226.272 mGy were measured at 99mTc, respectively, in the case of empty space and in the case of 0, 5 and 10 cm, while those of 18F were measured at 637.111, 724.469, 657.107, and 640.365 mGy, respectively. In order to reduce changes in surface dose depending on the patient's location while waiting, it is necessary to keep the distance from the ground or the wall where the patient is closely adhered to, or install an air mattress, etc., to prevent the scattered lines as much as possible, considering the scattered lines due to the wall etc. in future setup of the patient waiting room and safety room, and in addition to the examination, the external skin width may be reduced.

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.