• 제목/요약/키워드: air-dry density

검색결과 92건 처리시간 0.025초

Numerical Simulation of the Characteristics of Electrons in Bar-plate DC Negative Corona Discharge Based on a Plasma Chemical Model

  • Liu, Kang-Lin;Liao, Rui-Jin;Zhao, Xue-Tong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1804-1814
    • /
    • 2015
  • In order to explore the characteristics of electrons in DC negative corona discharge, an improved plasma chemical model is presented for the simulation of bar-plate DC corona discharge in dry air. The model is based on plasma hydrodynamics and chemical models in which 12 species are considered. In addition, the photoionization and secondary electron emission effect are also incorporated within the model as well. Based on this model, electron mean energy distribution (EMED), electron density distribution (EDD), generation and dissipation rates of electron at 6 typical time points during a pulse are discussed emphatically. The obtained results show that, the maximum of electron mean energy (EME) appears in field ionization layer which moves towards the anode as time progresses, and its value decreases gradually. Within a pulse process, the electron density (ED) in cathode sheath almost keeps 0, and the maximum of ED appears in the outer layer of the cathode sheath. Among all reactions, R1 and R2 are regarded as the main process of electron proliferation, and R22 plays a dominant role in the dissipation process of electron. The obtained results will provide valuable insights to the physical mechanism of negative corona discharge in air.

Water Lubrication System Supported by High-density Hydrophilic Polymer Brush

  • Kobayashi, Motoyasu;Ishihara, Kazuhiko;Takahara, Atsushi;Suzuki, Atsushi;Kaido, Masataka;Zhe, Wang
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.343-343
    • /
    • 2006
  • Surface-initiated atom transfer radical polymerization of 2-methacryloyloxyethyl phosphorylcholine (MPC) was carried out to produce high-density poly(MPC) brush on silicon wafer. Frictional properties of poly(MPC) was investigated by by sliding a glass ball (${\phi}\;10\;nm$) on the substrates over a distance of 20 mm at a sliding velocity of 90 mm/min under loading of 0.49 N at 298 K. Higher friction coefficients were observed in dry N2 atmosphere and in toluene condition, whereas the friction coefficients decreased to 0.02 in humid air and in water. It is supposed that water-swollen poly(MPC) brush works as a lubricant to moderate the interaction between brush and probe.

  • PDF

탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성 (Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device)

  • 전성중;이민영;권오빈;김종민;최민주
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.589-600
    • /
    • 2022
  • 탄도형 체외 충격파 치료기의 출력 에너지를 측정하는 Dry Test Bench(DTB)의 신뢰성을 검증하기 위해, 상용 탄도형 충격파 치료기에 대해 Laser Doppler Vibrometer(LDV)로 측정된 충격파의 음향 에너지와 비교했다. 실험 결과, DTB로 측정된 역학적 에너지는, 동일한 출력 설정에서, 5 % 이내의 변동성을 보이며, 치료기의 전 출력 설정 범위에서 LDV로 측정된 충격파의 음향 에너지와 선형적인 상관성(adj. R2 = 0.991)을 확인했다. 두 측정 방법의 상관성과, LDV을 이용하여 공기 및 수중에서 측정된 충격파 음향 에너지의 상관성(adj. R2 = 0.995)을 통합하면, DTB 측정으로부터 수중에서 발생된 충격파의 energy flux density를 평균 7.85 % 오차로 추정된다. DTB는 치료기의 출력에너지에 대한 정보만 제공하기 때문에, IEC61846 및 IEC63045에서 요구하는 다양한 충격파의 음향 출력을 시험하는 도구로 적합하지 않다. 그러나 측정 원리가 단순하고 사용이 용이한 DTB는 제조사 및 사용자가 탄도형 Extracorporeal Shock Wave Therapy(ESWT) 치료기의 성능을 관리하는 목적으로 유용하게 사용될 수 있을 것으로 기대된다.

시험밀도에 따른 조립재료의 전단강도 특성 (Characteristics of Shear Strength of Coarse Grained Materials Depending on Experimental Densities)

  • 김경열;이대수;홍성연;오기대
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.854-859
    • /
    • 2006
  • The density of coarse grained materials which is used in rock-fill dam or the piling the ground are used as $1.85\sim2.10g/cm^3$. Hereupon, the effect of variation of density on shear strength of ones was analyzed from the results of large scale shear test. The sample for the test was obtained from the local quarry sites. The test conditions are that density(1.85 versus $2.10g/cm^3$), material size range$(76.3\sim2.0\;mm)$, water content(air dry condition) and uniformity coefficient(5.0) Test result shows that the shear strength of $2.10g/cm^3$ is relatively larger than that of $1.85g/cm^3$.

  • PDF

폐타이어 재 자원화를 위한 연구 (A Study on Recycling of Waste Tire)

  • 이석일
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.38-44
    • /
    • 2000
  • Compared to other waste, waste tire has much discharge quantity and calorie. When we use waste heat from waste tire, it can be definitely better substitute energy than coal and anthracite in high oil price age. To use as a basic data for providing low cost and highly effective heating system, following conclusion was founded. Annual waste tire production was 19,596 million in 1999, Recycling ratio was almost 55% and more than 8.78 million was stored. Waste tire has lower than 1.5% sulfur contain ratio which is resource of an pollution, So it is a waste fuel which can be combustion based on current exhaust standard value without any extra SOx exclusion materials. Waste tire has 9,256Kcal/kg calorific value and it is higher than waste rubber, waste rubber, waste energy as same as B-C oil. When primary and second air quantity was 1.6, 8.0 Nm$^3$/min, dry gas production time was 270min and total combustion time was 360 min. In the SOx, NOx, HC of air pollution material density were lower than exhaust standard value at the back of cyclone and dusty than exhaust standard value without dust collector.

  • PDF

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권3호
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.

대기오염에 의한 치과위생사의 자각증상 특성 (A Sbjective Symptom on Outdoor Air Quality in Dental Hygienist)

  • 지동하;최미숙;손부순
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2007
  • This research is based on self-filling survey which 656 dental hygienists who work in, seoul, the metropolitan area, jeon-buk area participated on July 2006 through August 2006. This survey was analyzed the relationship between the subjective symptoms(6 types) and outdoor air quality($O_3,\;NO_2,\;CO,\;SO_2,\;PM_{10}$) As follows analyzed results. The health condition of dental hygienists were "Feel Good" more than 50% in last month. The experience the symptoms level is higher then non-experience level in "Dry eye, itch, smarting", "Headaches", "Fatigue and sleepiness", "Red eye", "Hypersensitivity", "Dorsalgia, omarthralgia, cervicodynia". We anticipated that the more experience the subjective symptom the more likely it is that outdoor air quality will be high rate level. But we could not find the uniformity in metropolitan-area and seoul-area. In the case of jeonbuk area, the group's pollution density levels which experienced the subjective symptom were appeared high rate than inexperienced group except $SO_2$. It probably comes from sensibility for an air pollution in this area. Dental hygienists who work in jeonbuk area have an unusual sensibility for an air pollution because outdoor air quality of jeonbuk area was rule good rather than others area. especially $SO_2$ was revealed out even though low rate level in inexperienced group it is that the number of cars in jeonbuk area is increasing rapidly.

건조 사질토 지반에 설치된 석션 버켓기초의 장기 반복하중에 의한 누적회전각 산정 (Accumulated Rotations of Suction Bucket Foundations under Long-term Cyclic Loads in Dry Sandy Ground)

  • 이시훈;최창호;김성렬
    • 한국지반공학회논문집
    • /
    • 제32권12호
    • /
    • pp.69-78
    • /
    • 2016
  • 최근에 해상 풍력발전기의 기초구조물로 석션 버켓기초가 적용되고 있다. 그런데, 석션기초는 보통 해양 연약지반에 설치되므로 장기 반복하중에 의해 누적변위가 발생할 수 있다. 본 연구에서는 1-g 모형실험을 수행하여 장기 수평 반복하중을 받는 석션 버켓기초의 누적 회전각을 분석하였다. 지반조건은 2가지 밀도의 건조 사질토 지반에 대하여 실험하였다. 모형석션 버켓기초의 근입깊이, 모형지반의 밀도, 반복하중의 크기를 변화시키며 실험을 수행하였다. 수평 반복하중은 일방향 재하로 최대 $10^4$번까지 재하하였다. 실험결과, 석션 버켓기초의 누적회전각은 재하횟수와 재하진폭이 증가에 비례하여 증가하였다. 실험결과를 이용하여 건조 사질토 지반에 근입된 석션 버켓기초의 장기 누적회전각을 산정할 수 있는 경험식을 제안하였다.

GPS를 이용한 대류권의 수증기량 추정에 관한 연구 (Estimation of Tropospheric Water Vapor using GPS Observation)

  • 송동섭;윤홍식;조재명
    • 한국측량학회지
    • /
    • 제20권2호
    • /
    • pp.215-222
    • /
    • 2002
  • As the GPS signals propagate from the GPS satellites to the receivers on the ground, they are delayed by the atmosphere. The tropospheric delay consists of two components. The hydrostatic (or "dry") component that is dependent on the dry air gasses in the atmosphere and accounts for approximately 90% of the delay. And the "wet" component that depends on the moisture content of the atmosphere and accounts for the remaining effect of the delay. The Zenith Hydrostatic Delay (ZHD) can be calculated from the local surface pressure. The Total Zenith Delay (TZD) will be estimated and the wet component extracted later. Integrated water Vapor (IWV) gives the total amount of water vapor that a signal from the zenith direction would encounter. Precipitable Water Vapor (PWV) is the IWV scaled by the density of water. The quality of this PWV has been verified by comparison with radiosonde data(at Osan). We processed data for JULY 2 and JULY 14, 1999 from four stations(Cheju, Kwangju, Suwon, Daegu). We found the coincidence between PWV of the estimations using GPS and PWV of pressing the radiosonde data. The average of the difference between PWV using GPS and PWV using radiosonde was 3.77 mm(Std. = $\pm$0.013 mm) and 2.70 mm(Std. = $\pm$0.0011 mm) at Suwon & Kwangju.

Methane-Air 혼합 Gas에서 구동하는 하니컴 형태의 SC-SOFC (Honeycomb-type Single Chamber SOFC Running on Methane-Air Mixture)

  • 박병탁;윤성필;김현재;남석우;한종희;임태훈;홍성안;이덕열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.306-309
    • /
    • 2005
  • One of the most critical issues in sol id oxide fuel cell (SOFC)running on hydrocarbon fuels is the risk of carbon formation from the fuel gas. The simple method to reduce the risk of carbon formation from the reactions is to add steam to the fuel stream, leading to the carbon gasification react ion. However, the addition of steam to fuel is not appropriate for the auxiliary power unit (APU) and potable power generation (PPG) systems due to an increase of complexity and bulkiness. In this regard, many researchers have focused on so-called 'direct methane' operation of SOFC, which works with dry methane without coking. However, coking can be suppressed only by the operation with a high current density, which may be a drawback especially for the APU and PPG systems. The single chamber fuel cell (SC-SOFC) is a novel simplification of the conventional SOFC into which a premixed fuel/air mixture is introduced. It relies on the selectivity of the anode and cathode catalysts to generate a chemical potential gradient across the cell. Moreover it allows compact and seal-free stack design. In this study, we fabricated honeycomb type mixed-gas fuel cell (MGFC) which has advantages of stacking to the axial direction and increasing volume power density. Honeycomb-structured SOFC with four channels was prepared by dry pressing method. Two alternative channels were coated with electrolyte and cathode slurry in order to make cathodic reaction sites. We will discuss that the anode supported honeycomb type cell running on mixed gas condition.

  • PDF