Study on Development of air-passing soundproofing panel (통풍형 방음벽 개발에 관한 연구 I)

  • Yoon, Je-Won;Sim, Sang-Deok;Kim, Young-Chan;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.638-643
    • /
    • 2011
  • The aluminum soundproofing panel used to the traffic noise reduction will judge with the material to improve because the CO2 emission is greater than other soundproofing panel such as plastic soundproofing panel. Also, if the air-passing soundproofing panel which can endure the fast wind velocity will be developed, it judged that it can reached to the target of low CO2 traffic technology development using the reduction of material cost and the lower consumption of steel. The objective of this study is to improve the soundproofing panel and to develop the air-passing soundproofing panel for the replacement of aluminum sound proofing panel which is more emit CO2 than other soundproofing panel. And, we tried to develop the reduction technology of CO2 emission through the development of air-passing soundproofing panel. At first, the flow and noise simulation were conducted for the purpose of the calculation of wind pressure on soundproofing wall and noise exposure level on receiver points according to the open ratio of air-passing soundproofing panel. And the 1st and 2nd mockup of air-passing soundproofing panel were made, and the design load test were conducted for these mockup.

  • PDF

A Study on the Variation of Airflow Velocity and Temperature upon the Design of Bio Clean Room(BCR) for Laboratory Animal Facilities by Numerical Simulation (실험동물 사육실용 바이오 크린룸(BCR)의 급기 온도 및 풍속 변화 특성에 관한 수치해석적 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.578-584
    • /
    • 2012
  • In this study, the analysis on the distribution of indoor airflow velocity and temperature by using numerical simulation has carried out to make fundamental data for establishing the optimum design of laboratory animal facilities. From the results, it was found that replacement of cage lacks, air supply and exhaust system, supply air temperature, supply air velocity affect to the optimum design of laboratory animal facilities as a important element.

An Experimental Study on Performance of Automotive Air conditioning System by using R-134a and R-152a (R-134a와 R-152a 냉매를 이용한 자동차용 에어컨 시스템의 성능에 관한 실험적 연구)

  • Kim, Jeong-Su;Lee, Dae-Woong;Yoo, Seong-Yeon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1225-1231
    • /
    • 2006
  • Recently, as the climate of temperature change has happened worldwide, To solve this problem, Kyoto protocol was taken to regulate global warming on Feb. 2005 and each country is making efforts to prevent global warming. In the automotive industry, R-134a refrigerant is widely used most these days because it has zero ODP(Ozone Depletion Potential). But R-134a GWP(Global Warming Potential) is so high. Therefore, replacement refrigerant desperately is needed as a alternative refrigerant. So, R-l52a is considered as one of the alternative refrigerants due to zero ODP and lower GWP against as required on Europe Committee. In this paper, performance of the air conditioning system between R-134a and R-152a is investigated experimentally. In the bench level, cooling capacity, condensing capacity, COP of automotive air conditioning system are ovaluated by means of air velocity entering the condenser and compressor revolution speed with optimized charge refrigerant quantity. Result of this study, R-152a refrigerant shows the possibility as alternative refrigerant of current R-134a in automotive air conditioning system.

  • PDF

Properties of Blast Furnace Slag Cement Modified with Electric Arc Furnace Slag (전기로 슬래그를 치환한 고로 슬래그 시멘트의 특성)

  • Lee, Seung-Heun;Hwang, Hae-Jeong;Kwon, Sung-Ku
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.7 s.290
    • /
    • pp.408-414
    • /
    • 2006
  • Properties of slag cement that contained 50 wt% of blast furnace slag were studied when replaced blast furnace slag powder with electric arc furnace slag powder. Electric arc furnace slag was aged for about 2 months in the air by being crushed to be 1-3 mm in size. As a result of the experiment, it was proven that the water content for obtaining the same consistency became decreased as slag is replaced with electric arc furnace slag instead of blast furnace slag. Also, the workability of mortar increased about 30% at the same ratio of water to binder when blast furnace slag was completely replaced with electric arc furnace slag. The compressive strength of mortar on the 28 days increased when a slag replacement rate became 10 wt%, however, it rather decreased when the slag replacement rate exceeded 10 wt%. The heat of hydration became higher for the first 14 h in case of the replacement of slag cement by electric arc furnace slag. Yet, it decreased when 14 h had passed. Therefore, when all blast furnace slag was replaced with electric arc furnace slag, about 15 cal/g heat of hydration decreased when it passed about 72 h.

A Study on the Sulfate Attack Resistance of Concrete Using EAF Slag as Fine Aggregate (전기로슬래그 잔골재를 사용한 콘크리트의 황산염침식 저항성에 관한 연구)

  • Park, Moon-Seok;Kim, Young-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to investigate the sulfate attack resistance of concrete using the EAF(electric arc furnace) Slag as fine aggregate. In order to figure out the effects of magnesium sulfate solution on the durability of concrete using the EAF Slag as fine aggregate, the experiments for the immerging test in the 10% magnesium sulfate solution was executed by selecting factors such as aging processes, replacement ratio(0, 10, 20, 30, 50%), and duration of immerging. The specimens were made with various EAF slag replacements for fine aggregates and with W/C ratio fixed 0.45. compressive strength and S.D.F(Sulfate Deterioration Factor), weight change, and SEM(Scanning Electron Microscope) were tested. From the test results, EAF slag aggregate treated with accelerated aging is better than treated with air aging. The compressive strength and resistance to the sulfate attack is slightly improved with an increase in the EAF slag aggregate treated with accelerated aging replacement for aggregate.

A Study on the Choice of Optimal Mixtures and Sensibility Properties of High Strength Concrete and Mass Concrete to apply the High Rising Building (초고층구조물에 적용하기 위한 고강도콘크리트 및 매스콘크리트의 최적배합선정 및 민감도특성에 관한 연구)

  • Lee, Sang-Soo;Song, Ha-Young;Kim, Eul-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.153-159
    • /
    • 2005
  • This study is to choose the optimal mixture and to analyze the sensibility properties of High strength concrete and mass concrete to apply the high rising building. The main experimental variables were water/binder ratio $39\%,\;33\%,\;35\%\;and\;37\%$, replacement ratio of fly ash $5\%,\;10\%\;and\;15\%$, in the high strength concrete and water/binder ratio $39\%,\;41\%\;and\;43\%$, replacement ratio of fly ash $10\%,\;20\%\;and\;30\%$, in the man concrete. According to the test results, the principal conclusions are summarized as follows. 1) The slump(or slump flow) and air content of fresh concrete were found to be the highest in the elapsed time 30 minutes. 2) The optimal mixture conditions are W/B $40\%$, FA $25\%$ in the mass concrete and W/B $33.4\%$, FA $15\%$ in the high strength concrete. 3) The ranges of sensibility are satisfied in the moisture content ${\pm}l\%\;and\;S/a\;{\pm}2\%$.

Fundamental Characteristics of High Strength SCMs Concrete According to Mixing Ratio of FA and BS (FA 및 BS의 혼합비율 변화에 따른 3성분계 고강도 콘크리트의 기초적 특성)

  • Kim, Min-Sang;Moon, Byeong-Yong;Lee, Jae-Jin;Park, Sung-Bae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.154-155
    • /
    • 2017
  • With the recent development in construction industry, industrial by-products fly ash(FA) and blast furnace slag(BS) have been used in large quantities as an alternative to cement, as a solution for environmental problems and resource exhaustion. This study analyzed the basic characteristics according to the changes in replacement ratio and mixing ratio of FA and BS in high strength SCMs concrete, from which in turn it sought to find the optimal mixing ratio for high strength concrete The results showed that in unhardened concrete the more the replacement ratio and FA mixing ratio increases the slump flow will increase while amount of air decreases, and setting time is delayed. In hardened concrete the more the replacement ratio and FA mixing ratio increases the more the overall compression strength decreases, but until 28 days of material age the larger of the BS ratio displayed the best compression strength.

  • PDF

Enhancement in the quality of mortar which uses uses 3-type blast-furnace slag cement and circulated fine aggregate, according to replacement ratio changes of waste refractories and desulfurized plaster (폐내화물 및 탈황석고의 치환율 변화에 따른 3종 고로슬래그 시멘트와 순환잔골재를 사용하는 모르타르의 품질향상)

  • Lee, Jae-Jin;Lee, Jea-Hyeon;Baek, Cheol;Kim, Min-Sang;Yoon, Won-Geun;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.56-57
    • /
    • 2016
  • Recently amongst Korea's construction companies there has been heightened interest in environment load reduction and resource recycling. As a result, the construction industry is examining recycled materials alternative to cement and blast-furnace slag (BS henceforth) cement, such as waste refractories and desulfurized plaster. This study analyzes the liquidity and intensity characteristics of mortar according to changes in replacement ratios of waste refractories and desulfurized plaster, used as industry by-products in mortar environments that use BS 3-type cements and circulated fine aggregate. As a result, the greater the increase in replacement ratios of desulfurized plaster, the greater the increase in liquidity and air quantity, as well as compression strength.

  • PDF

The Properties of Fluidity and Compressive Strength of Unsaturated Polyester Polymer Concrete According to Replacement Ratio of Rapidly-Chilled Steel Slag Fine aggregate (급냉 제강 슬래그 잔골재 대체율에 따른 불포화 폴리에스테르 폴리머 콘크리트의 유동성 및 압축강도 특성)

  • Kim, Jae-Won;Seo, Jung-Pil;Sun, Joung-Soo;Chi, Duck-Jin;Hwang, Eui-Hwan;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.43-46
    • /
    • 2007
  • This study dealt with the influence of the replacement ratio of rapidly-chilled steel slag on fluidity and compressive strength of unsaturated polyester polymer concretes. The rapidly-chilled steel slag used in this study, a by-product which is produced by refining pig iron during the manufacture of steel, was controled by a air-jet method which rapidly cools substance melted at a high temperature. Experimental results show that fluidity and compressive strength of unsaturated polyester polymer concretes increase with increasing replacement ratio of rapidly-chilled steel slag. Use of rapidly-chilled steel slag was found to be effective for improving fluidity and compressive strength of rapidly-chilled steel slag.

  • PDF

The Properties of Early Strength of Concrete Containing Slag and Fly-ash for In-situ Application (현장 적용을 위한 3성분계 콘크리트의 조기강도 특성)

  • Jung Chul-Hee;Kim Kyoung-Min;Lee Jin-Woo;Bae Yeon Ki;Lee Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.497-500
    • /
    • 2005
  • This study was performed to evaluate the characteristics which are slump, air content and time of set in fresh concrete and compressive strength of hardened concrete containing slag powder and fly-ash. Replacement rate of FA is fixed on 10$\%$ and replacement rate of slag powder are 0$\%$, 20$\%$ and 30$\%$. Also AE water-reducing agents(standard type, accelerating type) are used. The results were as follows. (1)Slump flow of concrete using AE water-reducing agents is similar. Flowability is incresed when replacement rate of slag powder is increased due to slag powder's ball bearing reaction.(2)Time of set of concrete using accelerating type agent is more faster than that of concrete using standard type agent because of ettringite generation that promote setting.(3)Early strength of three-component concrete using accelerating type agent is higher than that using standard type agent. Therefore cumulative pore is reduced due to ettringite

  • PDF