• Title/Summary/Keyword: air quality management

Search Result 664, Processing Time 0.035 seconds

A Study on the Brand Service Design for Measuring and Managing Indoor Air Quality (실내공기질 측정 및 관리를 위한 브랜드 서비스디자인 연구)

  • Kim, Seung-Beom;Kim, Hwoi-Kwang
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.325-333
    • /
    • 2018
  • The quality of indoor air quality is facing a very serious situation due to the impact of the quality of the atmosphere in the atmosphere and the surrounding environment. While awareness of the danger of these populations is increasing, there is no way to detect the quality of the indoor air quality as well as the measures to detect the quality of indoor air quality as well as the countermeasures. The study drew a general problem with the design of the service design, the general purpose of the general office, and the use of the public facilities for the purpose of measuring the usage of indoor air quality, the general purpose of public facilities, and the interpretation of the current law. Based on this research, most of the general users' perception of the seriousness of the disease is not reflected in the perception that the dust and indoor air are accumulated in the eyes of the general public.

Research of Real-Time Remote Operation for Quality Improvement of the Air-compressor : Case Study of Reciprocating Air-compressor (공기압축기의 품질향상을 위한 실시간 원격 운영시스템 연구 : 왕복동형 공기압축기 대상으로)

  • Im, Sang-Don;Kim, Jong-Rae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.33-40
    • /
    • 2014
  • Air compressor is an important facility with electric power in the industry. However, because of the noise and vibration of air compressor and is installed outside the building management difficulty. In this study, MCP (Micro Control Processor) to remote monitoring of the air compressor via the compressed air through improved quality and allows stable maintenance were designed. So, increase the productivity improvement of energy-saving effect can be obtained. Remote real-time information stored on your PC to manage air compressor equipment was higher reliability. Monitoring system is developed in this study was applied to embedded systems. It is easy to install air compressor, and low maintenance costs was to raise the economic impact.

A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites (환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구)

  • Lee, Jeong Joo;Lee, Ju Sang;Kim, Shin Do
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

Spatio-temporal estimation of air quality parameters using linear genetic programming

  • Tikhe, Shruti S.;Khare, K.C.;Londhe, S.N.
    • Advances in environmental research
    • /
    • v.6 no.2
    • /
    • pp.83-94
    • /
    • 2017
  • Air quality planning and management requires accurate and consistent records of the air quality parameters. Limited number of monitoring stations and inconsistent measurements of the air quality parameters is a very serious problem in many parts of India. It becomes difficult for the authorities to plan proactive measures with such a limited data. Estimation models can be developed using soft computing techniques considering the physics behind pollution dispersion as they can work very well with limited data. They are more realistic and can present the complete picture about the air quality. In the present case study spatio-temporal models using Linear Genetic Programming (LGP) have been developed for estimation of air quality parameters. The air quality data from four monitoring stations of an Indian city has been used and LGP models have been developed to estimate pollutant concentration of the fifth station. Three types of models are developed. In the first type, models are developed considering only the pollutant concentrations at the neighboring stations without considering the effect of distance between the stations as well the significance of the prevailing wind direction. Second type of models are distance based models based on the hypothesis that there will be atmospheric interactions between the two stations under consideration and the effect increases with decrease in the distance between the two. In third type the effect of the prevailing wind direction is also considered in choosing the input stations in wind and distance based models. Models are evaluated using Band Error and it was observed that majority of the errors are in +/-1 band.

Temporal Variation of Indoor Air Quality in Daycare Centers (어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가)

  • Kim, Yoonjee;Lee, Sewon;Ban, Hyunkyung;Cha, Sangmin;Kim, Geunbae;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

A Study on the effects of air pollution on circulatory health using spatial data (공간 자료를 이용한 대기오염이 순환기계 건강에 미치는 영향 분석)

  • Park, Jin-Ok;Choi, Ilsu;Na, Myung Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.3
    • /
    • pp.677-688
    • /
    • 2016
  • Purpose: In this study, we examine the effects of circulatory diseases mortality in South Korea 2005-2013 using the air pollution index, Methods: We cluster the region of high risk mortality by SaTScan$^{TM}$9.3.1 and compare this result with the regional distribution of air pollution. We use the Geographically Weighted Regression (GWR) to consider the spatial heterogeneity of data collected by administrative district in order to estimate the model. As GWR is spatial analysis techniques utilizing the spatial information, regression model estimated for each region on the assumption that regression coefficients are different by region. Results: As a result of estimating model of the collected air pollution index, circulatory diseases mortality data combined with the spatial information, GWR was found to solve the problem of spatial autocorrelation and increase the fit of the model than OLS regression model. Conclusion: GWR is used to select the air pollution affecting the disease each year, the K-means cluster analysis discover the characteristics of the distribution of air pollution by region.

Air Pollution Changes of Jakarta, Banten, and West Java, Indonesia During the First Month of COVID-19 Pandemic

  • PRAMANA, Setia;PARAMARTHA, Dede Yoga;ADHINUGROHO, Yustiar;NURMALASARI, Mieke
    • Asian Journal of Business Environment
    • /
    • v.10 no.4
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose: This research aims to explore the level of air pollution in Jakarta, the epicenter of COVID-19 Pandemic in Indonesia and its surrounding provinces during the first month of the Pandemic. Research design, data and methodology: This study uses data, which have been obtained real time from API (Application Programming Interfaces) of air quality website. The measurements of Air Quality Index (AQI), temperature, humidity, and other factors from several cities and regencies in Indonesia were obtained eight times a day. The data collected have been analyzed using descriptive statistics and mapped using QGIS. Results: The finding of this study indicates that The Greater Jakarta Area experienced a decrease in pollutant levels, especially in the Bogor area. Nevertheless, some areas, such as the north Jakarta, have exhibited slow reduction. Furthermore, the regions with high COVID-19 confirmed cases have experienced a decline in AQI. Conclusions: The study concludes that the air quality of three provinces, Jakarta, Banten, and West Java, especially in cities located in the Jakarta Metropolitan Area during COVID-19 pandemic and large-scale social restrictions, is getting better. However, in some regions, the reduction of pollutant concentrations requires a longer time, as it was very high before the pandemic.

Environmental Impact Assessment and Environmental Monitoring in Korea (한국에서의 환경영향평가와 환경측정)

  • Kang, In-Goo;Kim, Myung-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.3
    • /
    • pp.31-39
    • /
    • 1995
  • Environmental Impact Assessment (EIA) is composed of various procedures, such as screening, scoping, inventory survey, prediction, assessment, alternative assessment, mitigation measures, and post management. Environmental monitoring data for air quality or water quality, etc. is applied in the EIA process, especially in prediction and post management. As an effective tool of environmental monitoring, the remote sensing method, introduced recently, was used in collecting nationwide data concerning ecosystem and land use. This article explains the current monitoring status in Korea. Monitoring factors include air quality, water quality, soil, ocean, odor, noise, and ecosystems. This report explains the organization of the environmental monitoring system managed by the Ministry of Environment in Korea. Furthermore, it shows the environmental criteria and environmental policies applied to EIA in Korea.

  • PDF

A Study on Development of the Meteorological Data Preprocessing Program for Air Pollution Modeling (대기오염 모델링을 위한 기상자료 전처리 프로그램 개발에 관한 연구)

  • Lim, Ik-Hyun;Bae, Sung-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.47-54
    • /
    • 2015
  • Recently, rapid urbanization and industrialization had increased the air pollution in major cities by increasing the fuel consumption. Air pollution models have been widely used for air quality management in many countries. Also, a lot of related studies have been conducted using air dispersion models. In this study, The meteorological preprocessing program was developed to convert the korea meteorological data to the U.S. meteorological data and to expand the usability of air dispersion models of U.S. EPA. In addition, the usability evaluation was carried out through a case study. In the results of the evaluation of the program, this program was accurately convert the Korea meteorological data to the U.S. meteorological data, and the prediction was carried out without a error in air quality modeling. Therefore, the program showed a high utilization as meteorological data pre-processing tool.

Study on Improvement in Reliability of Analysis for VOCs and Aldehydes (대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰)

  • Lee M.D.;Lee S.U.;Lim Y.J.;Kim Y.M.;Kim S.Y.;Moon K.J.;Han J.S.;Chung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.