• 제목/요약/키워드: air monitoring

검색결과 1,512건 처리시간 0.031초

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

DEVELOPMENT OF A MAJORITY VOTE DECISION MODULE FOR A SELF-DIAGNOSTIC MONITORING SYSTEM FOR AN AIR-OPERATED VALVE SYSTEM

  • KIM, WOOSHIK;CHAI, JANGBOM;KIM, INTAEK
    • Nuclear Engineering and Technology
    • /
    • 제47권5호
    • /
    • pp.624-632
    • /
    • 2015
  • A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable.

본페로니 다중 분석 기반 대기오염 물질 모니터링 시스템 (Air pollution monitoring system based on Bonferroni multi-analysis)

  • 임병연;임현근;홍성택;정회경
    • 한국정보통신학회논문지
    • /
    • 제24권8호
    • /
    • pp.963-969
    • /
    • 2020
  • 지역 내의 도시들은 인구수, 계절, 교통량, 산업단지 등의 변수에 따라 대기오염의 수치가 다르게 관측되기 때문에 소규모 지역에 대해 정확하게 모니터링을 할 수 없는 문제점이 발생하고 있다. 이러한 문제점을 해결하기 위해 본 논문에서는 인체에 악영향을 미치는 대표적인 대기오염 물질 SO2, PM10, NO2, CO, O3이 관측되는 소규모 지역에 대해 결정계수(Coefficient of determination)를 통해 비교분석 하였다. 그리고 본페로니(Bonferroni) 다중 비교분석을 기반하여 기간별 대기 오염도를 나타내었다. 그리고 모니터링 시스템을 위해 지도를 각 소규모 도시의 좌표와 연동하여 분석 데이터를 기반으로 소규모 도시들에 대한 대기오염 물질을 시각화 하였다. 이를 통해 지역에 대한 대기오염 물질을 보다 정밀하게 사용자에게 모니터링 시스템을 제공할 수 있으며 일상생활에서 대기오염으로 발생할 수 있는 사고로부터 예방할 수 있을 것으로 보인다.

임베디드 시스템을 이용한 인터넷 제어감시 시스템에 관한 연구 (A Study on the Internet Control and Monitoring System using an Embedded System)

  • Haeng-Choon Chun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.811-817
    • /
    • 2004
  • Recently embedded systems are widely used in various industrial fields as supervisory controller because they have many merits. One of merits seems to be that operating environment of embedded system is the same as development environment using PC. That makes developing and manufacturing period shorten and also proper time to market Most of all machinery have sequential control system for their maneuvering which is composed of relays. contacts. timers. etc. In this paper. software sequential control system is proposed to be able to replace hardware sequential control system by using embedded system A lot of merits by the software sequential control system can be expected in the respect of economic reproduction, intelligent technologies and utilities, And porting of LINUX operating system to embedded system is carried out and device drivers and interface boards for LINUX 05 are designed for controlling air compressor by software Internet remote control and monitoring system of air compressor is implemented with Java script and CGI for these purposes. The experiment for operating air compressor system is taken through internet networks. The results show that developed system can be used for real plant.

비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템 (Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network)

  • 권종원;김조천;김규식;김희식
    • 전자공학회논문지SC
    • /
    • 제46권4호
    • /
    • pp.28-38
    • /
    • 2009
  • 본 연구에서는 비분산적외선(NDIR) 방식의 CO$_2$센서를 이용하여 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템을 구현하고 실제 지하철 승강장에 설치한 후 성능평가를 수행하였다. 서울 지하철은 하루 650만 명이 이용하는 대표적인 대중교통 수단이다. 따라서 승객뿐만 아니라 지하철 역사의 지하 공간에서 근무하는 많은 근로자들의 건강에 대한 관심이 높아짐에 따라 지하철 역사의 공기질 모니터링에 대한 요구가 매우 높아졌다. 현재 이런 요구를 충족하기 위해 환경부와 지하철 운영기관 측에서는 지하철역 공기질 모니터링 시스템을 일부 설치 운영 중이다. 그러나 고가의 수입 센서 이용으로 장비의 규모가 크고 설치 및 상시 운영에 따른 유지보수 비용이 큰 한계점이 있다. 따라서 본 연구에서는 저비용으로 CO$_2$ 농도를 상대적으로 정밀하게 측정할 수 있는 상용화된 CO$_2$ 센서에 대해 이론적으로 분석하고 신뢰성 검증 테스트를 수행하였다. 또한 무선 공기질 측정 센서 노드 및 게이트웨이 시스템을 개발하여 지하철 승강장의 실시간 공기질 데이터를 주기적으로 수집할 수 있고, 효율적으로 모니터링 할 수 있는 웹서버를 구축하였다. 본 연구 결과는 향후 지하 공간 공기질 관리 시스템의 확산 설치를 위하여 기초 연구 자료로 활용될 것이다.

Advances in gamma radiation detection systems for emergency radiation monitoring

  • Kumar, K.A. Pradeep;Sundaram, G.A. Shanmugha;Sharma, B.K.;Venkatesh, S.;Thiruvengadathan, R.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2151-2161
    • /
    • 2020
  • The study presents a review of research advancements in the field of gamma radiation detection systems for emergency radiation monitoring, particularly two major sub-systems namely (i) the radiation detector and (ii) the detection platform - air-borne and ground-based. The dynamics and functional characteristics of modern radiation detector active materials are summarized and discussed. The capabilities of both ground-based and aerial vehicle platforms employed in gamma radiation monitoring are deliberated in depth.

Air Pollution Trends in Japan between 1970 and 2012 and Impact of Urban Air Pollution Countermeasures

  • Wakamatsu, Shinji;Morikawa, Tazuko;Ito, Akiyoshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권4호
    • /
    • pp.177-190
    • /
    • 2013
  • Air pollution trends in Japan between 1970 and 2012 were analyzed, and the impact of air pollution countermeasures was evaluated. Concentrations of CO decreased from 1970 to 2012, and in 2012, the Japanese environmental quality standard (EQS) for CO was satisfied. Concentrations of $SO_2$ dropped markedly in the 1970s, owing to use of desulfurization technologies and low-sulfur heavy oil. Major reductions in the sulfur content of diesel fuel in the 1990s resulted in further decreases of $SO_2$ levels. In 2012, the EQS for $SO_2$ was satisfied at most air quality monitoring stations. Concentrations of $NO_2$ decreased from 1970 to 1985, but increased from 1985 to 1995. After 1995, $NO_2$ concentrations decreased, especially after 2006. In 2012, the EQS for $NO_2$ was satisfied at most air quality monitoring stations, except those alongside roads. The annual mean for the daily maximum concentrations of photochemical oxidants (OX) increased from 1980 to 2010, but after 2006, the $98^{th}$ percentile values of the OX concentrations decreased. In 2012, the EQS for OX was not satisfied at most air quality monitoring stations. Non-methane hydrocarbon (NMHC) concentrations generally decreased from 1976 to 2012. In 2011, NMHC concentrations near roads and in the general environment were nearly the same. The concentration of suspended particulate matter (SPM) generally decreased. In 2011, the EQS for SPM was satisfied at 69.2% of ambient air monitoring stations, and 72.9% of roadside air-monitoring stations. Impacts from mineral dust from continental Asia were especially pronounced in the western part of Japan in spring, and year-round variation was large. The concentration of $PM_{2.5}$ generally decreased, but the EQS for $PM_{2.5}$ is still not satisfied. The air pollution trends were closely synchronized with promulgation of regulations designed to limit pollutant emissions. Trans-boundary OX and $PM_{2.5}$ has become a big issue which contains global warming chemical species such as ozone and black carbon (so called SLCP: Short Lived Climate Pollutants). Cobeneficial reduction approach for these pollutants will be important to improve both in regional and global atmospheric environmental conditions.

연삭 작업상태 감시 시스템 개발 (Monitoring system of the grinding working conditions)

  • 김성렬;윤덕상;김화영;안중환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.387-390
    • /
    • 1997
  • Grinding process takes a long time that grinding machine is setted properly. It is difficult for user to judge correctly the abnormal states generated in grinding process. Air grinding has to be reduced for the improvement of productivity. In addition, it is important to monitor the dressing and the grinding process so that the grinding working maintains optimal grinding conditions. In this study, the monitoring system using the acoustic emission is developed to monitor these processes continuously. This system was able to reduce the preparation as well as the machine setting time in grinding operation.

  • PDF

Iot 기반 실내 공기오염 측정 시스템 (Iot based Indoor Air Quality Monitoring System)

  • 김웅태;김용철;곽수영
    • 한국콘텐츠학회논문지
    • /
    • 제16권2호
    • /
    • pp.143-151
    • /
    • 2016
  • 사람들이 집, 회사 등에서의 실내생활이 증가함에 따라 실내 공기오염에 대한 관심도가 높다. 본 논문에서는 실내 공기오염 중 인체에 가장 영향을 많이 미치는 이산화탄소, 미세먼지, 생활용품에서 발생되는 휘발성유기화합물(VOCs)를 측정할 수 있는 실내 공기오염 측정 시스템을 제안한다. 제안된 시스템은 실내 공기오염을 측정하는 디바이스, 정보를 저장하고 전송 할 수 있는 웹서버, 오염정보를 확인할 수 있는 안드로이드 어플리케이션으로 구성되어 있다. 본 시스템의 성능 확인을 위하여 초와, 담배연기 두 가지 시료의 실험을 통해 실내 공기 상태 변화를 어플리케이션으로 확인하였다. 또한, 외부 대기 상태와 디바이스로부터 측정된 내부 대기 상태를 비교할 수 있도록 시각화함으로써 사용자의 편의성을 증대시킬 수 있을 것으로 판단된다.

도로 재비산먼지 이동측정차량을 이용한 도로 재비산먼지 측정과 도로먼지 미량원소 분석 (Road Dust Emissions from Paved Roads Measured by Road Dust Monitoring Vehicle and Analysis of Trace Elements)

  • 이명훈;신정섭;신원근;이상구;김종;이창
    • 한국입자에어로졸학회지
    • /
    • 제8권2호
    • /
    • pp.47-54
    • /
    • 2012
  • Paved road dust emissions were investigated 14 times on 12 main roads in Seo-Cho Gu, Seoul, Korea by vehicle-based mobile sampling system(Road Dust Monitoring System) during September to December 2011. Also, fourteen heavy metals present in the dust samples were analyzed by ICP. ICP analysis showed that one of major source of the road dust would be urban construction. A large amount of silt was found, which might be originated mainly from building construction and open beds of trees. Trace element and pollution indices of heavy metals(Cd, Cu, Ni, Pb, Zn) on the roads adjacent to the commercial area had higher concentrations than those on the roads adjacent to the construction and residential areas because of traffic density and heavy traffic.