• 제목/요약/키워드: air meter method

검색결과 70건 처리시간 0.024초

Optimal location planning to install wind turbines for hydrogen production: A case study

  • Mostafaeipour, Ali;Arabi, Fateme;Qolipour, Mojtaba;Shamshirband, Shahaboldin;Alavi, Omid
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.147-177
    • /
    • 2017
  • This study aims to evaluate and prioritize ten different sites in Iran's Khorasan provinces for the construction of wind farm. After studying the geography of the sites, nine criteria; including wind power, topography, wind direction, population, distance from power grid, level of air pollution, land cost per square meter, rate of natural disasters, and distance from road network-are selected for the analysis. Prioritization is performed using data envelopment analysis (DEA). The developed DEA model is validated through value engineering based on the results of brainstorming sessions. The results show that the order of priority of ten assessed candidate sites for installing wind turbines is Khaf, Afriz, Ghadamgah, Fadashk, Sarakhs, Bojnoord, Nehbandan, Esfarayen, Davarzan, and Roudab. Additionally, the outcomes extracted from the value engineering method identify the city of Khaf as the best candidate site. Six different wind turbines (7.5 to 5,000 kW) are considered in this location to generate electricity. Regarding an approach to produce and store hydrogen from wind farm installed in the location, the AREVA M5000 wind turbine can produce approximately $337ton-H_2$ over a year. It is an enormous amount that can be used in transportation and other industries.

건조방법이 분말마늘의 품질에 미치는 영향 (The Effects of Drying Methods on the Quality of the Garlic Powder)

  • 정신교;최종욱
    • 한국식품과학회지
    • /
    • 제22권1호
    • /
    • pp.44-49
    • /
    • 1990
  • 열풍건조법과 동결건조법으로 제조한 분말마늘의 품질을 비교 조사하였다. 마늘의 휘발성 향기성분을 분리하는데 porapak Q 칼럼이 비교적 적합하였으며 FD-3구를 제외한 모든 동결건조구에서 열풍건조구에 비하여 diallyl disulphide, $P_t$, alliin의 함량이 높게 나타났다. 색차계로 분말마늘의 색도를 조사한 결과. 열풍건조구가 동결건조구에 비하여 갈변현상이 심하게 나타났으며 주사전자현미경으로 분말마늘의 미세조직을 관찰한 결과 동결건조 분말은 상당히 다공성이었다.

  • PDF

패턴된 전극을 가진 표면 전도형 단실형 고체산화물 연료전지의 제조 (Fabrication of Co-Planar Type Single Chamber SOFC with Patterned Electrodes)

  • 안성진;김용범;문주호;이종호;김주선
    • 한국세라믹학회지
    • /
    • 제43권12호
    • /
    • pp.798-804
    • /
    • 2006
  • Co-planar type single chamber solid oxide fuel cell with patterned electrode on a surface of electrolyte has been fabricated by robo-dispensing method and microfluidic lithography. The cells were composed of NiO-GDC-Pd or NiO-SDC cermet anode, $(La_{0.7}Sr_{0.3})_{0.95}MnO_3$ cathode, and yttria stablized zirconia electrolyte. The cell performance at $900^{\circ}C$ was investigated as a function of electrode geometries, such as anode-to-cathode distance, numbers of electrode pairs. Relationship between OCV and I-V characteristics at the optimized operation condition was also studied by DC source meter under the mixed gas condition of methane, air, and nitrogen. An increase of anode-facing-cathode area leads to lower OCV due to intermixing between product gases of anode and cathode, which in turn decreases the oxygen partial pressure difference.

나노유체 열전도도 특성 연구 (A Study on Thermal Conductivity Characteristics of Nanofluids)

  • 황유진;박재홍;김홍석;이재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.162-167
    • /
    • 2006
  • Nanofluid is a kind of new engineering material consisting of nanoparticles dispersed in base fluid. Nanofluids could have various applications such as magnetic fluids, heat exchanger working fluids, lubricants, drug delivery and so on in present study, various nanoparticles, such as MWCNT (Multi-walled Carbon Nanotube), fullerene, copper oxide, and silicon dioxide are used to produce nanofluids. As base fluids, DI-water, ethylene glycol, oil, and silicon oil are used. To investigate the thermo-physical properties of nanofluids, thermal conductivity and kinematic viscosity are measured. Stability estimation of nanofluid is conducted with UV-vis spectrophoto-meter. In this study, the high pressure homogenizer is the most effective method to produce nanofluid with the prepared nanoparticle and base fluid. Excellently stable nanofluids are produced with the magnetron sputtering system. Thermal conductivity of nanofluid increases with increasing particle volume fraction except water-based fullerene nanofluid which has lower thermal conductivity than base fluid due to its lower thermal conductivity, 0.4 W/mK. The experimental results can't be predicted by Jang and Choi model.

  • PDF

Outbreak of Bioaerosols with Continuous Use of Humidifier in Apartment Room

  • Lee, Ji-Hyun;Ahn, Kang-Ho;Yu, Il-Je
    • Toxicological Research
    • /
    • 제28권2호
    • /
    • pp.103-106
    • /
    • 2012
  • The effect of continuous humidifier use on the bioaerosol concentration in an indoor environment was investigated. An ultrasonic humidifier was operated for 10 hr per day for 15 days in an apartment room. During this time period, viable bioaerosol samples were taken using a single-stage Andersen sampler containing culture media plates for bacteria and fungi. The culture plates were then incubated at room temperature for 2~7 days depending on the media. The counts for the air sample plates were corrected for multiple impactions using the positive hole conversion method and are reported as the colony forming units per cubic meter of air (CFU/$m^3$). While the bacterial concentration measured using the tryptic soy agar (TSA) did not show any significant change during the first 3 days, the concentration increased from the $6^{th}$ day (6979 CFU/$m^3$) and reached a maximum on the $9^{th}$ day (46431 CFU/$m^3$). The concentration then decreased to 2470 CFU/$m^3$ on the $12^{th}$ day, at which point the fungal concentration increased rapidly to 14424~16038 CFU/$m^3$. Also, while the fungal concentration showed a significant change until the $9^{th}$ day of humidifier use, fungal growth was observed on the wallpaper and increased rapidly from the $12^{th}$ day. However, the bacterial concentration increased rapidly after the fungi were removed by remediation. The major fungal species identified in the samples were Penicillium representing 34%, Aspergillus representing 31%, Cladosporium representing 24%, and Alternaria representing 1%. The results also indicated that a relative humidity over 80% was easily achieved with continuous humidifier use. Yet, maintaining a high humidity in a room can cause a rapid outbreak of microbial growth.

가정 내 부유 진균의 농도와 관련 요인 (Airborne Fungi Concentrations and Related Factors in the Home)

  • 조용민;류승훈;최민석;서성철;정지태;최재욱
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.438-446
    • /
    • 2013
  • Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air ($CFU/m^3$). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 $CFU/m^3$, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 $CFU/m^3$. This was higher than non-atopy homes' 54.34 $CFU/m^3$ (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.

지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구 (A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure)

  • 송석준;유상건;박지웅;김은겸
    • 한국철도학회논문집
    • /
    • 제12권6호
    • /
    • pp.1024-1029
    • /
    • 2009
  • 콘크리트 구조물의 대형화에 따라 시공 중 수화열에 의한 온도 균열 발생 사례가 증가하고 있다. 지하철 콘크리트 BOX 구조물의 경우, 부재 두께가 1m 이상 되는 경우가 대부분이며, 특히 벽체는 외부구속에 의한 관통균열 발생으로 누수 및 조직 열화가 발생하여 내구성에 나쁜 영향을 주고 있다. 지하철은 일반적으로 도로를 따라 건설되므 로 교통체증을 줄이기 위한 공사기간 단축 시도가 종종 발생하게 된다. 본 연구에서는 공사시간 단축 방안으로서 한 지간씩 건너띠면서 콘크리트를 타설하는 시공방법을 제안하였으며, 이에 대한 온도균열제어에 미치는 영향을 검토하였다. 또한 벽체 높이, 타설온도, 대기온도 등을 현장조건에 따라 변화시켜 온도균열에 대한 민감도 분석을 실시하였다.

Bathythermograph Smoked-glass slide의 간역제작법 (SELF-PREPARATION OF BATHYTHERMOGRAPH SMOKED-GLASS SLIDE)

  • 허종수
    • 한국수산과학회지
    • /
    • 제1권2호
    • /
    • pp.135-137
    • /
    • 1968
  • 1938년 A. F. Spillaus에 의하여 Bathythermograph가 고안된 이내 현재까지 수차 개량된 것이 제작판매하게 되어 해양조사 또는 어장탐색에 총중한 측기로 세계 각국에서 널리 보급되었다. 이 측기는 항해중이라도 수심 270m까지 내렸다 올림으로써 수심에 대한 수온이 동시에 연속된 일선으로 도은 또는 Smoked한 유리 판상에 기록되어 신속하게 수온의 미세한 수직분포를 알 수 있어 어장탐사에 필요한 나층의 판별과 그 수탐 및 수온의 판단에 큰 도움을 준다. 여기에서는 1, 2연전 이내 수산진흥원 산하 각 해구 시험소 및 교육기관을 비롯한 해양조사 관계기관에 다수양이 공급되어 널리 사용되고 있는 B.T의 Smoked-glass slide가 없어 사용의 곤란성 및 일본 또는 미국으로부터의 수입의 귀찮은 수속을 해소시키기 위하여 본원에서 실험 제작사용한 결과로서 간단하게 B.T Smoked glass Slide를 제작할 수 있는 방법을 소개하고자 한다.

  • PDF

비산먼지 측정 정확도 개선을 위한 시뮬레이션 초음파 다중 산란 알고리즘 검증 (Evaluation of Ultrasonic Multiple Scattering Method to Improve the Accuracy of Fine Dust Measurement)

  • 우욱용;최하진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.119-128
    • /
    • 2020
  • 본 연구에서는 구조물 유지관리에서의 정확한 미세먼지 농도 계측을 위한 새로운 알고리즘을 제안하고 검증한다. 기존 광산란법 미세먼지 측정기의 측정 오차를 보완하기 위해 초음파 다중 산란 알고리즘을 제안하였으며, 산란자의 배치와 산란 반경을 구현하기 위해 표준입자 및 실제 미세먼지의 SEM 촬영을 진행하였다, 초음파 다중 산란 이론식을 통해 초음파 신호의 주파수별 감쇠율과 산란 반경으로 미세먼지의 개수밀도를 나타내는 알고리즘을 도출하였고, 이론식과 수치해석을 통해 총 12가지의 미세먼지 형상에 대한 산란 반경을 도출하였다. 유한차분법을 기반으로 다중 산란 이론을 적용한 2-D 시간 이력 해석을 통하여 알고리즘을 검증하였으며, 신호 해석을 위한 신호 처리 기법을 나타내었다. 결과, 산란 반경에 해당하는 알고리즘의 오차는 개수밀도 단위 최소 19(1%), 최대 3455(52%)로 계산되었다. 산란반경 외에 실제 미세먼지 형상에 대한 부피를 반영하여야 하는 추후 연구가 필요함을 토의하였다.

현장 타설 콘크리트의 단위수량 측정 및 관리 개선 방안 제시 (A Proposal for Improving the Measurement and Management of Unit Water Content in In-Situ Concrete)

  • 윤자연;장효준;이태규;최형길
    • 한국건축시공학회지
    • /
    • 제24권3호
    • /
    • pp.319-329
    • /
    • 2024
  • 본 연구에서는 국내외 단위수량 규정을 조사하고 현장 타설 콘크리트의 단위수량을 평가하였다. 콘크리트 품질을 타이틀로 하여 핵심 단어 시각화했을 때 단위수량이 높은 중요도를 가짐을 확인할 수 있었다. 또한 단위수량 관리 및 단위수량 측정 방법에서 한국과 일본 간 상대적으로 큰 차이가 나타나지 않음을 알 수 있었다. 현장에 반입된 콘크리트의 단위수량을 단위용적질량법을 이용하여 계산한 결과, 현장에서 임의로 채취한 샘플에서 단위수량이 불균일하고 가변적이며, 단위수량이 적정 단위수량 기준을 초과하는 결과를 확인할 수 있었다. 현장 타설 콘크리트의 품질관리를 위해서는 레미콘 업체, 건설업체, 검사관이 단위수량에 대한 엄격한 기준을 준수하는 것이 중요하며, 명확한 단위수량 측정 매뉴얼 제공과 철저한 교육, 주기적인 현장 점검 등 보다 체계적이고 실용적인 시스템 구축이 필요하다고 판단된다.