• Title/Summary/Keyword: air humidity

Search Result 1,847, Processing Time 0.032 seconds

Oceanography in the Waters Adjacent to Kamchatka and Kurile islands in the Northwestern Pacific - II (북서태평양 명태 어장의 해황 - 2 . 기후의 특성 -)

  • Han, Young-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.13 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • For four calender years (1971-1974), daily observations of weather conditions (air temperature, humidity, wind speed, wind direction, cloud amount, fog, precipitation etc.) at six stations in the north western Pacific Ocean are used to calculate mean monthly values and to check extra-conditions. At Petropavlosk and Miko'skoe, where indicate the characteristics of modified continental climate, the temperature and humidity are high in summer, and Iow in winter. At A Dak and She Mya, where indicate the characteristics of warm current type maritime climate, humidity is high in all season and annual range of air temperature is nearly negligible. At Simusir and Vasi!' eva, where indicate the characteristics of cold current type maritime climate, humidity is high in all season and annual range of air temperature is $15^{\circ}C.$ As dry cooling power is relatively high in winter, working condition on deck is bad. Most of fogs are advection fog in the area of cold current type climate in summer.

  • PDF

An Experimental Study on the Thermal Environmental Measurements and Subjective Reponses in Summer Season for the Korean Traditional Houses in Chonnam Province (전남지방 전통주택의 하절기 온습도 측정 및 주관평가에 관한 실험적 연구)

  • Kim Sun-Woo;Lee Tai-Kang;Kim Hyung-Ryul
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.41-46
    • /
    • 2006
  • This study aims to analyzed thermal comfort characteristics and subject response for thermal environment of Korean traditional houses.. The air temperature and humidity in the living area of the residence were measured in during a day. And the subject response were surveyed to evaluate of controling the thermal environment factor (temperature, humidity, comfort) of the korean traditional houses. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls. And environmental control for the air temperature and humidity is estimated considerably satisfactory.

Analysis of Temperature and Humidity Distribution in a Dry Room (Dry Room내의 온.습도 분포 해석)

  • 이관수;임광옥;안강호;정영식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.524-531
    • /
    • 2001
  • The temperature and humidity distribution in a dry room are studied numerically by using standard$\kappa-\varepsilon$ turbulence model. In order to evaluate effective heat and moisture ventilation characteristics inside the room, the heat removal capacity and moisture exhaust efficiency are introduced. An effective ventilation control is analyzed by evaluating quantitatively temperature and humidity distributions. It was found that the mean absolute humidity inside the room was almost constant with approximately 0.1905g/kg air regardless of the models and the heat generation rates. This was believed that the moisture generation by workers was relatively small. 40% improvement of the critical decay time was achieved, through the modifications of design variables.

  • PDF

Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply (고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

A Study on the Contamination of Photovoltaic Cells by Fine Dust in the Air (공기 중의 미세먼지에 의한 태양전지의 오염에 관한 연구)

  • HAN, JIN MOK;CHOI, SOOKWANG;KIM, SEWOONG;JUNG, YOUNGUAN
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.3
    • /
    • pp.292-298
    • /
    • 2018
  • The contamination of photovoltaic (PV) cells reduces the incidence of sunlight and reduces the power generation output of PV cells. The main factor influencing the contamination of PV cells installed outdoors is the fine dust in the air, but the influence of temperature, humidity, rain and wind can be considered. In this paper, experiments on the contamination of PV cells according to the fine dust density, the temperature and humidity of air were investigated. As results of this study, the contamination area of PV cells increases with contamination time and cumulative fine dust density in the air. The contamination of PV cells increases when the temperature is low and the humidity is high. Also, as the contamination of PV cells is affected to the wind, the deviation of contamination area is happened.

Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction (백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구)

  • Wang, Zhen-Huan;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

Influence of air pressure, temperature, humidity and CO$_{2}$ concentration on optical phase changes in thin films

  • Kim, Moon-Hwan;Tachikawa, Yoshihiko;Ogita, Eiji;Ueda, Toshitsugu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.799-804
    • /
    • 1989
  • A new method for measuring optical phase changes of reflection beam from optical mirror is proposed. The optical phase change is liable to change with varying atmosphere conditions. This optical phase changes are measured against air pressure, temperature, humidity and CO$\_$2/ concentration variations. It is clarified that the optical phase changes are most effected by humidity change.

  • PDF

Characteristics of Meteorological Environment Variation Before and After Construction of Nak-dong River Estuary Barrage (낙동강 하구둑 건설 전·후의 기상환경 변화 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.135-145
    • /
    • 2005
  • This study was conducted to investigate the characteristics of meteorological environment variation before and after construction of Nak-dong river estuary barrage. We used meteorological data(air temperature, precipitation, relative humidity, visibility, wind) at Gimhae airport meteorological station. The construction of river estuary barrage can change climate at the neighboring districts and influence human's health and vegetable. The construction of Nakdong river estuary barrage brought rise of temperature, decrease of relative humidity and increase of poor visibility frequency.

Analysis on the Thermal Comfort Aspect of a Locally-Cooled Room in Warm and Humid Environments : PPD-Based Evaluation of Human Responses (중온 고습 환경조건에서 부분적으로 냉방되는 실내의 열쾌적성에 대한 분석 : 인체반응에 대한 PPD 기준의 평가)

  • Kim, Bong-Hun;Seo, Seung-Rok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.41-59
    • /
    • 1998
  • Thermal comfort aspect of a locally-cooled target space in warm and humid environments(typically in the rainy summer season) was studied in view of PPD index. First. theoretical analyses were conducted to examine the effect of the governing parameters(such as air temperature, relative humidity and air velocity, etc.) using a computer model. Secondly, experimental investigations were also performed in a climatic room designed to simulate corresponding thermal conditions of outdoor environments. During the tests, temporal variation of PPD was recorded as functions of climatic variables(outdoor and indoor temperatures, relative humidity and air velocity) for the given human factors(metabolic heat generation and clothing). From both theoretical and experimental investigations, air temperature and air velocity were found to be the most dominant parameters affecting PPD of the target space. Results were summarized as: 1. Relative humidity of the locally-cooled target space tends to approach that of outdoor's as the space is subjected to an ON-OFF mode of cooling, since moisture potential of the two rooms reaches an equalized state as a result of moisture diffusion. 2. It was recognized that changes in relative humidity did not show any significance in view of thermal comfort as was reported in the previous studies, while variations of both temperature and air velocity caused relatively large changes in the degree of thermal comfort. 3. In-door environment should be evaluated in terms of PPD instead of relative humidity commonly recognized as an important climatic variable particularly in warm and humid environments.

  • PDF

Theoretical Analysis and Optimization of Extrinsic Fabry-Perot Interferometer Optical-fiber Humidity-sensor Structures

  • Yin, Xiao Lei;Wang, Ning;Yu, Xiao Dan;Li, Yu Hao;Zhang, Bo;Li, Dai Lin
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.652-659
    • /
    • 2021
  • The theoretical analysis and optimization of extrinsic Fabry-Perot interferometer (EFPI) opticalfiber humidity sensors are deeply investigated. For a typical dual-cavity structure composed of an optical fiber and a humidity-sensitive membrane (HSM), the changes in refractive index (RI) and initial length are discussed for polymer materials and porous oxide materials when relative humidity (RH) increases. The typical interference spectrum is simulated at different RH using MATLAB. The spectral change caused by changing HSM RI and initial length are simulated simutineously, showing different influences on humidity response. To deeply investigate the influence on RH sensitivity, the typical response sensitivity curves for different HSM lengths and air-cavity lengths are simulated. The results show that the HSM is the vital factor. Short HSM length can improve the sensitivity, but for HSM RI and length the influences on sensitivity are opposite, because of the opposite spectral-shift trend. Deep discussion and an optimization method are provided to solve this problem. According to analysis, an opaque HSM is helpful to improve sensitivity. Furthermore, if using an opaque HSM, a short air cavity and long HSM length can improve the sensor's sensitivity These results provide deep understanding and some ideas for designing and optimizing highly sensitive EFPI fiber humidity sensors.