• Title/Summary/Keyword: air environmental indices

Search Result 76, Processing Time 0.027 seconds

Effect of the Hose Slurry Spreader on Oder Reduction (호스지표살포기의 악취감소효과 분석)

  • 오인환;김기덕
    • Journal of Animal Environmental Science
    • /
    • v.7 no.2
    • /
    • pp.119-126
    • /
    • 2001
  • For the odor test, it was chosen the conventional spreader, the hose spreader, and its combination with disk harrow and spring harrow as a slurry spreader. By the odor tester (Kalmor-$\sum$) with dairy slurry, the conventional spreader has the average $\sum$ value of 270, which means that one fells substantial odor and torment. In the cases of hose spreader and its combination with disk harrow, $\sum$ value was 217 and 182 respectively, which means a normal person does not smell any odor. Spreading the swine slurry with a conventional spreader shows $\sum$ value of 440, which means one feels unpleasant. The hose spreader shows $\sum$ value of 258, which lies in the limit one feels some odor and torment. Its combination with disk harrow has $\sum$ value 184, which means that a normal person can not smell any more. For the conventional spreader, the odor intensity indices from air dilution sensual test and 3 point odor bag as a sensual test were 66.9 and 35.4 respectively. On the other hand, the indices were 9.65 and 11.10 by hose spreader and its combination with disk harrow, which were lower than that of the regulation for industry. Therefore, the developed hose spreader showed an excellent effect on decreasing odor. The correlation between the results from odor tester and 3 point odor bag has shown 0.997 by swine slurry.

  • PDF

A Study on the Indoor Air Pollution in the Classrooms of Primary, Middle and High Schools in Seoul and Gyeonggi-Do (서울.경기지역 초.중.고등학교 교실의 실내공기오염에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Moon, Jeong-Suk;Kim, Sang-Uk
    • Journal of the Korean Society of School Health
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2003
  • This study was conducted to contribute to the basic data for decisions on environment policy improvement in health promotion for students in elementary, middle and high schools. This study was carried out to investigate the extent of indoor air pollution in elementary, middle and high schools in residential, traffic congestional and industrial areas. The concentrations of major indoor air pollutants(carbon monoxide, carbon dioxide, respiratory particulate, radon) and thermocircumstance (temperature, relative humidity, intensity of illumination) indices were observed from June to August 2000. As results of the survey, the mean values of thermocircumstance in school were $26.94{\pm}1.15^{\circ}C$ of temperature, $68.88{\pm}5.31%$ of humidity and $268.26{\pm}164.60$ Lux of intensity of illumination. The mean concentrations of carbon monoxide, carbon dioxide, respiratory particulate were $8.36{\pm}0.29\;ppm$, $547.66{\pm}175.58\;ppm$, $36.23{\pm}48.39\;{\mu}g/m3$, respectively. These values were lower than those of the indoor environmental standard on the first clause of Article 45 of public utilization service notified public hygiene of the Ministry of Health and Social Affairs. The mean concentration of radon was $20.07{\pm}17.95\;Bq/m3$. Which was below the U.S. EPA radon action level.

Public Environment Index Development (환경상태의 평가를 위한 주민환경지표의 개발)

  • Kim, M.J.;Choi, D.I.;Chang, C.K.;Lee, J.W.
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 1993
  • As the environmental concerns have shifted gradually from the environmental pollutions to the Quality of Life (QOL) enhancement, it has become increasingly important to implement comprehensive assessment of environmental quality for public information as well as decision making. This study focuses on development of PEI(Public Environment Index) which has purposes to improve regional environment and analyzes the status of environment by public as one kind of environmental indices. Factors of PEI calculations are air, water, noise, green space and landscape. Factors are composed of 20 items including soiling and odor. Major contents are calculation of PEI, correlation analysis of factors and items of PEI, regression analysis of PEI and objective environmental indicators prepared as a dong unit, and PEI presentation using GIS. Also, for applying PEI effectively, environmental information as a dong unit is to be collected and managed periodically.

  • PDF

Development of an IAQ Index for Indoor Garden Based IoT Applications for Residents' Health Management (실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발)

  • Lee, Jeong-Hun;An, Sun-Min;Kwak, Min-Jung;Kim, Kwang Jin;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.421-432
    • /
    • 2018
  • Objectives: In this study, we started to develop an indoor garden integrated IoT solution based on IAQ (indoor air quality) and interconnection with an environmental database for smart management of indoor gardens. The purpose of this study was to develop and apply an integrated solution for customized air purification from an indoor garden through big data analysis using IoT technology. Methods: An IoT-based IAQ monitoring system was established in three households within a new apartment building. Based on real-time and long-term data collected, $PM_{2.5}$, $CO_2$, temperature, and humidity changes were compared to those of indoor garden applications and the analyzed results were indexed. Results As a result of the installation, all three households had no results exceeding the standard for indoor air pollution on average $PM_{2.5}$ and $CO_2$ indices. In the case of indoor garden installation, the IAQ index increased to the "Good" section after the installation, and readings in the "Bad" section shown before the installation disappeared. The comfort index also did not dip into the "Uncomfortable" section, where it had been preinstallation, and significantly lowered the average score from "Uncomfortable for sensitive groups" to "Good". Overall, the IAQ composite index for the generation of installations decreased the "Good" interval, but "Bad" did not appear. Conclusions In this study on developing an integrated solution for IAQ based on IoT indoor gardens, big data was analyzed to determine IAQ and comfort indexes and an IAQ composite index. Through this process, it became understood that it is necessary to monitor IAQ based on IoT.

Spatial Distributions of the Ambient Levels of Air Pollutants in Seoul Metropolitan Area (대기오염도의 공간적 분포 변화 분석 -수도권 지역을 대상으로-)

  • Kwon, Oh Sang;An, Donghwan;Kim, Wonhee
    • Environmental and Resource Economics Review
    • /
    • v.13 no.1
    • /
    • pp.83-117
    • /
    • 2004
  • This study investigates the spatial distributions of the ambient levels of air pollutants ($SO_2$, $NO_2$, $O_3$, CO, and PM) in Seoul metropolitan area using the data obtained by the air pollution observation stations. This study estimated a non-parametric kernel density function and two types of inequality indices, Gini and Entropy. Our estimation results show that the degree of inequality in spatial distribution of air pollution, in general, tends to be stable or slightly decreasing for the period of 1990~2001. In addition, we found that there are significant dynamics of air pollution levels in terms of spatial ranking.

  • PDF

Performance of Air Fresher System for the Removal of Various Odorants Released from Foodstuffs

  • Kim, Ki-Hyun;Adelodun, Adedeji A.;Deep, Akash;Kwon, Eilhann E.;Jeon, Eui-Chan;Kim, Yong-Hyun;Jo, Sang-Hee;Lee, Min-Hee;Cho, Sung-Back;Hwang, Ok-Hwa
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.37-53
    • /
    • 2017
  • The effectiveness of four air fresher (AF) systems was evaluated with respect to their removal efficiencies against offensive odorants. For this purpose, malodorous species were generated by exposing freshly cooked foods emitting odorants with levels moderately above their respective threshold values in a confined room. The deodorization efficiency of the four AF systems was then tested for a period of 30 min by estimating the extent of reduction in odorant levels after the operation of each AF. The removal efficiency of the four AF units against each odorant was evaluated as follows: (1) between AF products from different manufacturers, (2) between odorants and ultrafine particulate matter ($PM_{2.5}$), and (3) between operation and natural degassing. The average sorptive removal of odorants was generally <80% and considered less effective or non-effective relative to $PM_{2.5}$. Further examination of odor reduction, if evaluated in terms of odor indices like odor intensity (OI) and odor activity value (OAV), recorded a mean of 33% and 87%, respectively. The overall results of this study confirmed that all tested AF units were not effective to resolve odor problems created under our testing conditions.

Electricity Generation and Microbial Community Structure Variation Depending on Separator Types and Cathode Characteristics in Air-cathode MFC (공기환원전극 미생물연료전지에서 분리막 종류 및 환원전극 특성에 따른 전기발생 및 미생물 군집구조 변화)

  • Yu, Jae-Cheul;Lee, Chang-Yeol;Kim, Sun-Ah;Cho, Hae-In;Cho, Sun-Ja;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.113-120
    • /
    • 2010
  • Air-cathode microbial fuel cell consisted of 4 unit cells were operated under batch condition and electricity generation and microbial community structure variation were investigated, depending on separator types and cathode characteristics: A) PEM(Proton Exchange Membrane)-30% Wet proofing Carbon Cloth(WC), B) AEM(Anion Exchange Membrane-WC, C) CEM(Cation Exchange Membrane)-WC, D) PEM-No Wet proofing Carbon Cloth(NC). Maximum power densities of PEM-WC, AEM-WC and CEM-WC were 510.9, 522.1 and 504.8 $mW/m^2$, respectively. But PEM-NC showed relatively lower maximum power density of 218.3 $mW/m^2$. And PEM-WC, AEM-WC and CEM-WC showed similar internal resistances(20.0-28.2 ${\Omega}$). PCRDGGE, PCA and diversity indices showed that uncultured bacteria which reported in previous MFC studies were detected in suspended growth bacteria and attached growth bacteria would be affected not by separator type but by cathode characteristic. Thus, cathode characteristic can be one of the critical factors for power generation in air-cathode MFC using PEM, AEM, and CEM as separator.

Effects of Storage Time and Temperature on the Hygienic Quality of Shell Eggs (계란의 저장·보관 조건에 따른 위생적 품질 변화)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.438-448
    • /
    • 2015
  • Objectives: This study was performed to examine the effects of storage time and temperature and their interaction on the hygienic quality parameters of shell eggs. Methods: Eggs from 40-week-old Hy-Line Brown hens were sampled immediately after being laid and subjected to storage periods of four weeks at a refrigerated temperature ($4-5^{\circ}C$) or room temperature ($13.0-19.7^{\circ}C$). Interior/exterior qualities were examined every one week. Results: Weight loss was 2.4-3.1%. The initial specific gravity of the eggs was maintained until one week at both temperatures. Air cell size exceeded 4 mm when stored for one week at room temperature, and two weeks at refrigerated temperature. Albumen index and Haugh unit were significantly decreased at both temperatures after one week (p<0.001). Rapidly increased pH of the albumen with one week of storage was observed, regardless of temperature (p<0.001). Extension of the storage for up to four weeks at room temperature resulted in remarkable deterioration of eggshell quality and instrumental color as redness (a). Air cell size, albumen and yolk indices, Haugh unit, pH of albumen and yolk were found to be influenced by storage time and temperature (p<0.001). Interaction effects between storage time and temperature were also significant for air cell size, pH of albumen and yolk (p<0.001). Conclusion: The results suggest that air cell size and pH of albumen and yolk were important parameters influenced by storage time and temperature in shell eggs. Storage time was more influential for air cell size, and temperature for the pH of yolk. Both variables almost equally influenced the pH of albumen.

Air Ventilation Evaluation at Nighttime for the Construction of Wind Corridor in Urban Area (도시지역의 바람길 조성을 위한 야간시간대의 공기순환성 평가)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.16-29
    • /
    • 2013
  • The purpose of this study is to evaluate air ventilation using wind patterns of MetPhoMod program at nighttime focused on Changwon-si, Gyeongsangnam-do. Evaluation indices of air ventilation are wind resistant and retention used by results of each wind speed and diversity. The results are as follows. Vulnerable areas of air ventilation are Bonglim-dong, Bansong-dong, Yongji-dong and so on. In high-rise apartment, commercial area and single residential area of Yongji-dong, Sangnam-dong and Sapa-dong, wind is stagnated by high buildings. Therefore, these areas should construct urban spaces to circulate the wind. And to inflow persistingly the fresh wind generated in a rural area, we think that the construction of wind corridor is suggested by development plan and policy wind corridor.

Evaluation of Mobile Emissions Reduction Strategies Using Travel Demand Model and Analytic Hierarchy Process (교통수요모형과 의사결정모형을 이용한 자동차 배출저감정책 평가)

  • Lee, Kyu Jin;Park, Kwan Hwee;Shim, Sang Woo;Choi, Keechoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1123-1133
    • /
    • 2015
  • This study proposed an evaluation method of mobile emissions reduction strategies for air quality management. The proposed method was considered Travel Demand Model (TDM) and Analytic Hierarchy Process (AHP), while an existing method was focused on quantitative factors. AHP of the evaluation indices of mobile emissions reduction strategies show that quantitative evaluation indices such as air pollutants and greenhouse gas reduction are more important than the political evaluation indices (Consistency with an upper plan, Policy applicability, Technical applicability and feasibility) and each weight of air pollutants and greenhouse gas reduction are found to be 0.373 and 0.218. The early scrapping policy of decrepit diesel vehicle is the best policy in the proposal method using TDM and AHP but this result differs from evaluated result by TDM or AHP respectively. These results are limited to the basic assumption and range of reduction scenarios but are expected to contribute to establish more reasonable and effective mobile emission reduction strategies.