• 제목/요약/키워드: air duct

검색결과 538건 처리시간 0.028초

프로펠러 팬과 덕트와의 상대위치가 유동특성에 미치는 영향 (The effect of position of propeller fan relative to duct inlet on flow characteristics)

  • 심우찬;조강래;주원구
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.14-22
    • /
    • 1997
  • The position of propeller fan from duct inlet is one of basic parameters for the design of propeller fan. To investigate the effect of its position on fan characteristics, the inlet flow fields and relative flow angles were measured by a 5-hole pitot tube. The experimental results indicate that the ratio of radial flow introduced from propeller circumference to total inlet flow increases with the increase of propeller distance from duct inlet. When fan operates without duct, the total flow rate and the radial flow ratio are higher than those of any other positions of propeller relative to duct inlet. The radial flow ratio decreases as a flow coefficient and the propeller distance decrease. Therefore the front flow fields can be adjusted in some extent by varying the propeller distance according to a fan loading. The inlet flow angles are decreasing a little as a rotational speed and the propeller distance decrease. In the present case it was judged that the deviation angle of outlet flow became negative owing to a flow separation near a trailing edge.

  • PDF

공조기가 설치된 고분 내에서의 열 및 음 환경 평가 (Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System)

  • 박진양;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

G7 동력차 동력실 유동해석을 통한 루프후드 구조 연구 (The study for roof hood structure of G7 power car engine compartment using air flow analysis.)

  • 박광복;장규호;이동훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.634-644
    • /
    • 2000
  • The study was carried out about the roof hood structure of power car for Korean High Speed Train. The compatibility for applied material and volume of hood duct was studied using analysis about heat and flow distributions. The materials and volume of duct were mainly determined by output air temperature and flow rate of each electric blocks. This report was described, which focuses on pressure distribution and air temperature within engine compartment of power car.

  • PDF

화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동 (Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex)

  • 김철홍;주영호;변형현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

환기용 덕트내의 전달소음 특성에 관한 연구 (A Study on the Transmitted Noise Characteristics through the Ventilating Duct)

  • 최한림;김경환;최호선;오세기;정백영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

Design of Solar Cell Cooling System Using Convection Phenomena

  • Lee, Jae-hyuk
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.123-128
    • /
    • 2020
  • We constructed a cooling system for solar cells using convection phenomena and investigated its cooling performance. The cooling system didn't need any driving power or water resources. The convection cooler manufactured with a right-triangle shape of an air duct was attached to the rear of the solar cell to confirm that cooling was performed using convection phenomena. When the ratio of duct width to attachment surface width was 3:7, and the ratio of entrance height and exit height of duct was 5:1, it showed the best cooling performance. Comparative experiments with solar cells without convection cooler showed that cooling effects from 16.5℃ to 20.9℃ occurred after 40 minutes exposed to the 1300W Xenon lamp condition.

덕트형 세정집진기의 입자포집 특성실험 (An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber)

  • 유경훈;여국현;손승우;황광호;정진원;김윤신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

곡면 엘보우를 가진 사각덕트 내의 유속측정 및 수치계산에 관한 연구 (Study on Velocity Measurement and Numerical Computation in a Rectangular Duct with $90^\circ$ Bend Elbow)

  • 윤영환;박원구
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.910-917
    • /
    • 2003
  • Fluid flow in a rectangular duct for 90$^{\circ}$ bend elbow with the ratio of 1.5 between its curvature radius and width is measured by 5 W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between measured and computed velocity profiles in the duct. Reynolds numbers for the comparison are 11,643, 19,746 and 24,260. From the comparison, computation of principal velocity components in the duct predicts the experimental data somewhat satisfactorily even though those of minor velocity components and turbulent kinetic energy do not match with the experimental data quite well. K-factor for the bend elbow is computed to be average 0.086 while the equivalent ASHRAE data is 0.07.

공간 절약형 환기덕트를 위한 챔버 개발에 관한 연구 (Development of Ventilation Duct Chamber for Reducing Space)

  • 김상진;최상식;이성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.535-539
    • /
    • 2008
  • The machinery ventilation system in case of using the window nature ventilation is difficult due to strong outdoor wind pressure is common ventilation measure. increasing height and decreasing economical efficiency problem because of ventilation duct installation is rising and a measure is urgent. The purpose of this study is analysis required height according to each ventilation system and development of ventilation duct system to reducing height and model testing.

  • PDF