• Title/Summary/Keyword: air and water temperatures

Search Result 404, Processing Time 0.035 seconds

Relationship between Weather factors and Water Temperatures, Salinities in the West Sea of Korea (한국 서해에서 기상인자와 수온, 염분과의 관계)

  • Lee Jong Hee;Kim Dong Sun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.11a
    • /
    • pp.181-185
    • /
    • 2003
  • the effect if atmosphere is more important in the West sea of Korea than in other seas because of shallow water and heat storage if the water. The serial oceanographic observation data and coastal station data from NFRID, and the atmosphere data from KMA were used in order to find out the relationship between them The highest water temperature, salinity and weather factor were recorded in Aug, and the lowest of them in Feb. As the water deepens, the maximum time leg in water temperature and the minimum time leg in salinity. Water temperature have the maximum in Oct, the minimum in Apr at 75m of the 311-07 station with 100m depth water temperature (WT)-air temperature, WT-precipitation (Preci.) and salinity (Sal)-wind speed (WS) were in direct proportion, but WT-WS, Sal-AT and Sal-Preci in inverse proportion Water temperature and salinity I-ave time leg at the same depth the maximum had more the delay of $2\~4$ months at a depth if 20 meters than at the surface in all stations except for salinity at 307-05.

  • PDF

Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator (쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구)

  • Lee, Geum-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

Preparati on and Characterization of $LnTaO_4$ (Ln = La, Nd, Sm, Dy, Er and Tm)

  • Fujita, Atsushi;Matsushita, Hiroaki;Katsui, Akinori
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1116-1117
    • /
    • 2006
  • Lanthanide tantalite $LnTaO_4$ (Ln= La, Nd, Sm, Dy, Er and Tm) was synthesized by a solid state reaction between mixed powders of $Ln_2O_3$ and $Ta_2O_5$. The single-phase $LnTaO_4$ was prepared by sintering at temperatures of 1423-1673 K in air. The SEM observation showed that the particles were provided with the growth steps and the depeloped facets. The photocatalytic activity for water splitting of $LnTaO_4$ prepared was measured under UV light irradiation. The activity obtained was higher than that previously reported. These results suggested the crystallinity of $LnTaO_4$ photocatalysts correlates closely with the efficiency of water splitting.

  • PDF

Effect of firing temperatures on alkali activated Geopolymer mortar doped with MWCNT

  • Khater, H.M.;Gawwad, H.A. Abd El
    • Advances in nano research
    • /
    • v.3 no.4
    • /
    • pp.225-242
    • /
    • 2015
  • The current investigation aims to study performance of geopolymer mortar reinforced with Multiwalled carbon nanotubes upon exposure to $200^{\circ}C$ to $1000^{\circ}C$ for 2 hrs. MWCNTs are doped into slag Geopolymer mortar matrices in the ratio of 0.0 to 0.4, % by weight of binder. Mortar composed of calcium aluminosilicate to sand (1:2), however, binder composed of 50% air cooled slag and 50% water cooled slag. Various water / binder ratios in the range of 0.114-0.129 used depending on the added MWCNT, while 6 wt., % sodium hydroxide used as an alkali activator. Results illustrate reduction in mechanical strength with temperature except specimens containing 0.1 and 0.2% MWCNT at $200^{\circ}C$, while further increase in temperature leads to decrease in strength values of the resulting geopolymer mortar. Also, decrease in firing shrinkage with MWCNT up to 0.1% at all firing temperatures up to $500^{\circ}C$ is observed, however the shrinkage values increase with temperature up to $500^{\circ}C$. Further increase on the firing temperature up to $1000^{\circ}C$ results in an increase in the volume due to expansion.

An Analytical Study on a Heat Transfer Mechanism with Boiling Effect between Two Fluids in a Mini-channel (미세채널내 증발을 고려한 두 유체간 열전달현상에 대한 해석적인 연구)

  • Yoo, YoungJoon;Choi, Sangmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.114-121
    • /
    • 2013
  • In order to estimate the efficiency of an evaporative heat exchanger having mini channel, the equations to calculate heat exchanger properties, those are air temperatures and water temperatures etc, are derived from the governing equations based on the Navier-Stokes equation, even though there are several assumptions to make problem simplify. There are three heat transfer zones at the mini channel heat exchanger depending on the water condition. So, there are three governing equations and solutions to calculate the properties. As the results of this study, the equations to calculate a saturation point and a dry point are derived to evaluate an evaporative heat exchanger having micro channel. It is supposed to predict and evaluate the performance of a mini channel heat exchanger with evaporation of liquid.

The Activities of Human Autonomic Nervous System by Foot Bathing (족욕이 인체 자율 신경기능에 미치는 영향에 관한 연구)

  • Kim H.J.;Yu M.;Choi K.J.;Yang Y.S.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1929-1932
    • /
    • 2005
  • We investigated the activities of autonomic nervous system during foot bathing. The effect of foot bathing was evaluated for four subjects by observing the characteristic of heart rate variability and bodily temperatures. The foot bathing was done with a commercial foot spa (Duches Co.) utilizing the four functional modes of the spa for two different temperatures of $35^{\circ}C\;and\;40^{\circ}C$. The four functional modes were clam, vibration, air bubbles, and both vibration and air bubbles. The experimental results showed that the temperature of foot and that of face right after foot bathing were not that different from each other. But, for heart rate variability, the activation of parasympathetic nerve showed distinctive increase at $40^{\circ}C$ of water temperature. In the analysis of heart rate variability for different functional modes, the change was not distinctive for different modes at $35^{\circ}$ of water temperature. However, at $40^{\circ}C$, the activation of sympathetic nerve showed distinctive increases with the increase in the complexity of functional modes.

  • PDF

Effects of various cooling methods and drinking water temperatures on reproductive performance and behavior in heat stressed sows

  • Habeeb, Tajudeen;Joseph, Moturi;Abdolreza, Hosseindoust;SangHun, Ha;Jun Young, Mun;YoHan, Choi;SooJin, Sa;JinSoo, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.4
    • /
    • pp.782-791
    • /
    • 2022
  • The purpose of this study is to evaluate the effects of multiple cooling systems and different drinking water temperatures (DWT) on the performance of sows and their hair cortisol levels during heat stress. In this study, the effect of four different cooling systems: air conditioner (AC), cooling pad (CP), snout cooling (SC), and mist spray (MS), and two DWT, namely low water temperature (LWT) and high water temperature (HWT) on 48 multiparous sows (Landrace × Yorkshire; 242.84 ± 2.89 kg) was tested. The experiment is based on the use of eight replicas during a 21-days test. Different behaviors were recorded under different cooling treatments in sows. As a result, behaviors such as drinking, standing, and position change were found to be lower in sows under the AC and CP treatments than in those under the SC and MS treatments. Lying behavior increased under the AC and CP systems as compared with that under the SC and MS, systems. The average daily feed intake (ADFI) in sows and weight at weaning in piglets was higher under the AC, CP, and LWT treatments than under the SC, MS and HWT treatments. Sows subjected to SC and MS treatment showed higher hair cortisol levels, rectal temperature, and respiratory rate during lactation than those under AC and CP treatments. Hair cortisol levels, rectal temperature, and respiratory rate were also higher under the HWT than under the LWT treatment. As per the results of this study, the LWT has no significant effect on any of the behavioral factors. Taken together, the use of AC and CP cooling treatment is highly recommended to improve the behavior and to reduce the stress levels in lactating sows.

Studies on the Environmental Factors Affecting Growth and Tuber Formation of Eleocharis kuroguwai Ohwi (올방개(Eleocharis kuroguwai Ohwi)의 생장(生長)과 괴경형성(塊莖形成)에 미치는 환경요인(環境要因))

  • Ku, Y.C.;Choung, S.G.
    • Korean Journal of Weed Science
    • /
    • v.13 no.1
    • /
    • pp.44-54
    • /
    • 1993
  • This experiment was conducted to understand the environmental factors affecting growth and tuber formation such as temperature, day length, tight intensity, water condition and cutting time of Eleocharis kuroguwai Ohwi. Plant height, shoot number and dry weight of E. kuroguwai were higher at high temperature, 25/$25^{\circ}C$ (day/night), while nitrogen content was higher at low temperature, 20/$15^{\circ}C$. Plant height was more affected by water temperature, while shoot number and dry weight were more affected by air temperature. Contents and absorption of nitrogen, phosphorus, and potassium in top parts of E. kuroguwai were higher under greater difference between air and water temperatures, i.e., 18/$28^{\circ}C$ and 28/$18^{\circ}C$. The number and weight of tubers were increased under greater difference between air and water temperatures, i.e, 18/$28^{\circ}C$ and 28/$18^{\circ}C$, while they were inhibited at low or high air/water temperatures (18/$18^{\circ}C$ or 28/$28^{\circ}C$). Tubers of E. kuroguwai were formed at 8-or 12-hour day length, however, no tuber was formed at l6-hour day length. Photoinductive period for tuber initiation of E. kuroguwai was between 30 and 45 days after emergence, and the induction period of short-day treatment was less than 10 days. Tuber number and weight were reduced by shading due to inhibition of the growth of top and underground parts. Number of days from planting to tuber initiation was shortned as planting time was delayed and plant height, dry weight, and tuber number were also reduced by delayed planting. Tuber number at l0 to 15cm water depth was decreased 63 to 75% as compared with 1 to 5cm water depth. Tuber number and dry weight were not affected by the size of tubers at planting. Due to the reduced growth of top and underground parts, tuber number and dry weight of E. kuroguwai were decreased by delayed shoot cutting. The critical cutting time to inhibit the growth of E. kuroguwai was about 70 days after emergence.

  • PDF

Kinetics of Water Vapor Absorption by Sodium Alginate-based Films

  • Seog, Eun-Ju;Zuo, Li;Lee, Jun-Ho;Rhim, Jong-Whan
    • Preventive Nutrition and Food Science
    • /
    • v.13 no.1
    • /
    • pp.28-32
    • /
    • 2008
  • Water vapor sorption by sodium alginate-based films may result in swelling and conformational changes in the molecular structure and affecting the water vapor barrier properties. Sodium alginate film specimens were dried in a vacuum freeze dryer and their moisture content was determined by an air-oven method. The water vapor absorption was determined at two different levels of water activities (0.727 and 0.995) and at three temperatures (10, 20, and $30^{\circ}C$), and kinetics were analyzed using a simple empirical model. Reasonably good straight lines were obtained with plotting of 1/($m-m_0$) vs 1/t. It was found that water vapor absorption kinetics of sodium alginate films were accurately described by a simple empirical model. The rate of water vapor sorption increased with increase in temperature and it showed temperature dependency following the Arrhenius equation. The activation energies varied from 49.18$\sim$149.55 kJ/mol depending on the relative humidity.

Prediction of the Environmental Conditions in Underground Tunnelling Spaces (地下터널 굴착作業場內 作業環境豫測)

  • Park, Hee-Bong
    • Tunnel and Underground Space
    • /
    • v.2 no.1
    • /
    • pp.116-122
    • /
    • 1992
  • A comprehensive, nonsteady state, computer simulation program for the environmental conditions in advancing tunnels (the HEADSIM simulation program) is constructed and successfully validated with heat balance amongst all heat sources, and with mass conservation amongst various airflows including the leakage air from ducts, under timedependent variations of inlet air conditions. which include sudden, diurnal and seasonal changes. Heat conduction in the wall strata and face strata is simulated with most complicated boundary conditions using the finite difference method, and the climatic conditions in roadway sections which contain air ducts, booster fan, spray cooler, compressed air pipes, cold water pipes, return water pipes, machinery and broken rock are simulated taking into account the variations of face operation and the heat storage mechanism in the strata. The limitations of simulation time steps and roadway section lengths are defined according to the stability criteria satisfying the principles of thermodynamics. Variations of heat transfer coefficients, which are newly set, and those of wetness factors are taken into account according to the variations of other parameters and the stepwise advance of the face. Newly-derived formulae are used for computing the air duct leakage and the pressure inside of the duct. A new concept of an 'imaginary duct' is introduced to simulate the climatic conditions in tunnels during holiday periods, which directly affect conditions on subsequent working days under the consideration of natural convection. A subsidiary program (the WALLSIM simulation program) is made to compute the dimensionless tunnel surface temperatures and to compare the results with those from analytical approaches, and to demonstrate the stability, convergence and accuracy of the strata heat conduction simulation, adopting the finite difference method. The WALLSIM also has wide applications, including those for the computation of age coefficients.

  • PDF