• 제목/요약/키워드: aggregate resources

검색결과 559건 처리시간 0.029초

Physical Properties of Artificial Interior stone Using Waste Resources (폐자원을 활용한 내장용 인조석재의 물리적 특성)

  • Yoo, Yong-Jin;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • 제14권3호
    • /
    • pp.237-243
    • /
    • 2014
  • The environmental problem is serious due to global warming In a concrete industry, the effort to reduce the problem of the destruction of environment arising from the indiscriminate use of limestone that is the raw material of cement and aggregate and the exhaustion of resources are continually emphasized In this research, the waste porcelain and waste glass that are the natural aggregate substitute materials were mixed and were applied. In addition, the magnesia phosphate composite and fly ash are mixed with a cement substitute material and the properties of the artificial stone was examined. Density, water absorption, rate of aggregate on the surface, compressive strength, and flexural strength were performed. As a result of the test, it is that waste glass with 60% and waste porcelain with 70% are the most excellent mix to produce the artificial stone.

Evaluation of Mechanical Properties of Early-age Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로 산화슬래그를 혼입한 초기재령 콘크리트의 역학적 특성 평가)

  • Kwon, Seung-Jun;Hwang, Sang-Hyeon;Lim, Hee-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제7권2호
    • /
    • pp.93-100
    • /
    • 2019
  • In this study, the mechanical properties of early-age concrete were evaluated by mixing the electric arc furnace oxidizing slag fine aggregate with 30% and 50% replacement ratio. Slump test, air content test and unit volume weight test were performed for fresh concrete, and compressive strength test and chloride penetration experiments were carried out in hardened concrete. The compressive strength increased up to 7 days of curing age with increasing replacement ratio of the electric furnace oxidizing slag, but the strength decreased to 90% level of OPC concrete at 28 days of age. Regarding the result of chloride penetration test, no significant differences from OPC concrete were evaluated, which shows a feasibility of application to concrete aggregate.

Evaluation of Properties and Stability to use Floor Materials for Cogeneration Power Plant as Fine Aggregates for Concrete (열병합 발전소 바닥재를 콘크리트용 잔골재로 활용하기 위한 기초 물성 및 안정성 평가)

  • Kang, Suk-Pyo;Hong, Seong-Uk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제10권3호
    • /
    • pp.321-326
    • /
    • 2022
  • In this study, cogeneration power plants that use biomass as a raw material to convert them into energy have recently received a lot of attention worldwide and are gradually increasing in South Korea. Therefore, in order to confirm the possibility of using the generated floor material as a fine aggregate for concrete, properties and stability evaluation experiments were performed. Compared to standard sand, the compressive strength of wood chip aggregate was improved by 11 % to 111 %, the length change rate was 89 %, and the waste processing test results met all criteria for hazardous substances. All of these are satisfied, and it is judged that the floor materials by the cogeneration power plant can be used as a fine aggregate for concrete.

Performances of Prepacked-Type Thermal Conductive Backfills Incorporating Byproduct Powders and Aggregates (부산물 분체 및 굵은 골재를 활용한 프리팩트형 열전도성 되메움재의 성능)

  • Sang-Min Jeon;Young-Sang Kim;Ba-Huu Dinh;Jin-Gyu Han;Yong-Sun Ryu;Hyeong-Ki Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제11권3호
    • /
    • pp.169-176
    • /
    • 2023
  • This study aims to develop a thermally conductive backfill by applying the prepacked concrete concept, in which a coarse aggregate with relatively high thermal conductivity was first filled and then the voild filled with grout. Backfill with improved thermal conductivity can increase the heat exchange efficiency of underground heat exchangers or underground transmission facilities. The backfills was prepared by using crushed concrete as the coarse aggregate, fly ash-based grout, and a small amount of cement for solidification. The results of this study showed that the fly ash-cement-sand-based grout with a flow of at least 450 mm accor ding to ASTM D 6103 could fill the void of pr epactked coar se aggr egates with a maximum size of 25 mm. The thermal conductivity of the backfil with coarse aggregate was over 1.7 W/m·K, which was higher than that of grout-type backfills.

Consideration on the Application of Low-Heat Concrete with Ferronickel Slag Aggregate to LNG Storage Tank (페로니켈슬래그 골재를 활용한 저발열 콘크리트의 LNG 저장탱크 적용성 검토)

  • Sang Hyeon Cheong;Sukhoon Pyo;Hyeong-Ki Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제12권1호
    • /
    • pp.17-24
    • /
    • 2024
  • The characteristics of low-heat concrete, mixed with ground blast furnace slag and ferronickel slag aggregate, were analyzed. Moreover, the applicability of this concrete for mass concrete in LNG storage tanks was examined. Initially, the study investigated the characteristics of fresh and hardened concrete. Subsequently, the temperature rising curve was obtained. Utilizing the obtained parameters from the curves, a series of thermal stress analyses for the LNG storage tank were conducted to assess the risk of cracking. The results confirmed that concrete mixtures incorporating ground blast furnace slag and ferronickel slag aggregate not only exhibited sufficient workability but also achieved a compressive strength of approximately 40 MPa within 28 days. Furthermore, the concrete demonstrated a lower terminal heat rise and a faster heat generation rate compared to low-heat Portland cement concrete. An analysis of thermal stress in various sections of the LNG tank validated a low risk of cracking.

A Study on the Bearing Capacity of Rammed Aggregate Pier as the Intermediate Foundations (중간기초개념으로서 짧은 쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • CHUN BYUNG-SIK;KIM KYUNG-MIN;KIM JUN-HO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.247-252
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the bearing capacity and failure behavior characteristics was studied through soil laboratory tests in a model ground. In this study, soil laboratory tests use carried out to find the applicability of RAP method as the foundation of a structure. And bearing capacity and the failure mechanism of RAP method was studied according to relative density($60\%,\;70\%,\;90\%$), diameter(45mm, 60mm, 70mm) of each pier ana depth(5cm, l0cm, 15cm, 20cm, 25cm, 30cm). Earth pressure cell is set up approach RAP and 1.0D space at RAP center. Bearing acpacity and the failure mechanism of RAP is investigated by load test As a result, bulging failure was happened in $5\~10cm\;(1.0D\~2.00)$ depth which the maximum lateral earth pressure is acting. Especially, diameter changing of RAP are in inverse proportion to the relative density and the lateral stress is very much influenced by the lateral earth pressure in every layer and tends to decrease according to depth.

  • PDF

A Experimental Study on the Construction Material Using the Circulation Resources (폐콘크리트 순환자원을 이용한 건설재료의 특성연구)

  • Hong, Se-Hwa;Son, Ki-Sang;Choi, Jea-Nam
    • Journal of the Korean Society of Safety
    • /
    • 제25권2호
    • /
    • pp.41-46
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. This result has same decreasing proportion to tensile strength of the material. Resistant capacity change of beam varying with recycled powder mixture has been decreased down to 60% of normal concrete bean capacity, while there are 80% decrease of material strength. But strength and capacity change has same consistent decrease ratio. It is found that recycled powder with approximately 15% unit concrete volume can be replaced with cement in reasonable admixture mixing condition.

The Application of Copper Smelting Slag as Concrete aggregate (콘크리트용 동슬래그 골재의 활용 기술)

  • Ji, Seok-Won;Seo, Chee-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • 제2권2호
    • /
    • pp.68-75
    • /
    • 2006
  • The total production of the smelted copper reaches 450,000 tons per year, and the production of copper-related goods grows year by year owing to the extension of facilities and the development of production techniques. On the other hand, the volume of slag discharges by-produced at the time of copper smelting process is also on trend of increase. The by-produced copper smelting slag amounts to 700,000 tons a year, which is one and half times of the total smelted copper production. Accordingly nobody disagrees that comprehensive researches on how to deal with and how to reuse the accumulated smelting copper slag have to be encouraged. Even though the possible uses of the copper smelting slag have being made on various levels at present as materials for iron powder cement, sand-blasting and fire-proofing rock wool, but a considerable volume of the slag is abandoned as unnecessary by burying or piling up in careless in the open ground.

  • PDF

A Research on the Recycling of Ceramic Wastes as an Aggregate for Concrete (窯業廢棄物을 콘크리트용 骨材로 再活用하기 위한 硏究)

  • 문한영;김기형;신화철
    • Resources Recycling
    • /
    • 제10권2호
    • /
    • pp.41-49
    • /
    • 2001
  • In this study, the properties of cement mortar and concrete using ceramic wastes as fine aggregates and coarse aggregates are considered experimentally. Flow value of mortar using ceramic waste as fine aggregates is increased more or less, and the com- pressive strength of mortar using ceramic wastes as fine aggregates is increased with elapsed age. The slump value of concrete using ceramic wastes fine aggregates and coarse aggregates is somewhat decreased. The compressive strength of concrete using ceramic wastes as fine aggregates and coarse aggregates is lower than that of OPC concrete in early age, but has gradually increased in long ages.

  • PDF

Assessment of Environmental Contamination caused by the Stone-dust using Leaching Tests (용출실험에 의한 석분토의 지표환경 오염 평가)

  • Kang, Min-Ju;Lee, Pyeong-Koo;Youm, Seung-Jun
    • Journal of Soil and Groundwater Environment
    • /
    • 제15권3호
    • /
    • pp.52-60
    • /
    • 2010
  • The stone-dust is an unavoidable by-product of aggregate production, which is produced about 0.8~1.0 million $m^3$ annually. The stone-dust is currently regarded as a hazard material on environment because it is classified as an industrial waste in the Waste Management Law of Korea. At present, the stone-dust is considered as a environmentally hazardous material, and is classified as an industrial waste according to the Waste Management Law of Korea. In this study, we assessed the heavy-metal contamination of the stone-dust on surrounding environments by various leaching tests. Leaching experiments (such as Korea Standard Leaching Procedure (KSLP), Soil Environment Preservation Act of Korea (SEPAK), Toxicity Characteristic Leaching Procedure (TCLP), and Synthetic Precipitation Leaching Procedure (SPLP)) show that very low heavy metals (As, Cd, Cu, Pb, Zn, Hg) and CN are leached out, or much less than each regulatory thresholds. The resuts of the leaching test with time in acidic solution (initial pH 5 and 3) indicate that pH-buffering minerals are present in the stone-dust. These results suggest that the stone-dust can not potentially affect adverse impact on surrounding environments such as surface water, groundwater and soil etc..