• Title/Summary/Keyword: advanced daylighting systems

Search Result 9, Processing Time 0.022 seconds

Comparative Analysis on Configurations and Characteristics of IEA's Advanced Daylighting Systems (IEA 첨단채광시스템의 형상 및 특성에 관한 비교분석)

  • Kim, Jeong-Tai;Chung, Yu-Gun;Ahn, Hyun-Tai;Ahn, Hyug-Keun
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • New and innovative technologies for utilizing daylight in buildings have been developed for saving energies and improving visual environments. This study describes the most up-to date information available about the application and evaluation of advanced daylighting systems to enhance daylighting in non-residential buildings from IEA's Task 21. IEA's Task 21 consists on 4 subtasks such as "Performance Evaluation of Daylighting Systems(subtask A)", "Daylighting Responsive Controls(subtask B)", "Daylighting Design Tools(subtask C)" and "Case Studies(subtask D)". For the study, the configurations and characteristics of IEA's advanced daylighting systems are comparatively analyzed. As results, innovative daylighting systems are designed to redirect sunlight or skylight to areas which it is required without glare. These systems use optical devices that initiate reflection or refraction of sunlight and skylight. And they can be designed to actively track the sun or passively control the direction of sunlight and skylight. The comprehensive overview of innovative daylighting systems presented in this study helps designer to understand the advantages of daylighting in building and choose a suitable system for building in the earliest stage of the design process.

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

A Study on Daylighting Systems for Therapeutic Environments of Healthcare Facilities (의료시설의 치유적 환경을 위한 자연광조명시스템에 관한 연구)

  • Jung, Hee-Boon
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.139-148
    • /
    • 2016
  • Chronic patients and staffs in healthcare facilities cannot avoid long-term stays indoors. Therefore, they need to get adequate amounts of sunlight to prevent diseases caused by vitamin D deficiency. This is a case study on the advanced daylighting systems installed to healthcare facilities for therapeutic environments as serving natural light therapy and a pleasant atmosphere. This paper shows daylighting devices that overcome the structural limits of architectural design solutions for inducing natural light. This study presents appropriate daylighting technologies to the purpose and types of healthcare facilities by analyzing therapeutic environmental factors. Natural light delivered through daylighting devices help directly patients recover. In addition, it can improve healthcare providers' performance and productivity, and reduce their errors, thereby creating therapeutic environments for patients, indirectly. Excellent color rendering of solar illumination is also a powerful tool for navigation and wayfinding in the buildings, and for aesthetic treatment in dental office. Furthermore, daylighting systems are streamlined and require the least material and space to attract sunlight up to the deeper inside. But because of expensive cost, they have not yet been widespread. Though daylighting devices are typically more expensive than artificial illuminations to install, the running cost savings can compensate for the initial installation cost. With the development of technology in the future, the market price of them is expected to be formed properly.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Application of Lightself to Buildings as a Integrated Daylighting System (건축물 일체형으로서 광선반형 자연채광시스템의 건축물 적용기법에 관한 연구)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.17-24
    • /
    • 2002
  • For sustainable building design, using day lighting is considered a variable technique to save energy and create comfort indoor environments. Specially, the lightself as a integrated daylighting system is one of the most important techniques due to it's durability, availability and lighting performance. This paper aims to analyze the development and architectural application of a lightself system to buildings as a integrated day lighting system. For the study, advanced lightself systems developed in abroad such as "Integrated Enveloped and Lighting System", "Anidolic Daylighting System" and etc. are analyzed. Also, the architectural examples are investigated. As results, the new technologies such as optically treated reflective and sun-tracking are adopted to improve daylight performance. And, lots of environmentally friendly buildings are installed on integrated lightself system.

Comparative Performance Evaluation of Advanced Daylighting Glazing Systems by Scale Model Measurements (축소모형을 이용한 가변 유리투과체의 채광유형별 성능평가 비교)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • The conventional way to acquire sufficient amount of daylight in interiors is to provide large openings with clear glass. The use of clear glass on the whole facade, however, might cause a sort of visual problem because of the harness of direct sun and brighter sky surface than expected. They should be filtered in opticalway or bounced in the architectural. One of the common solutions for the problem might be the use of photometric glasses with various transmittances for the glass walls. This paper deals with performance data related to the impact of various transmittal glazing materials for window systems in terms of daylighting. A series of scale model measurements was carried out with the fundamental configuration of a commonly used all-glass facades. Additionally some experimental performance index was issued for the better expression of the need of natural lighting.

Energy Efficient Lighting Control Facilities Related to Daylight Levels (주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능)

  • Kim, Jeong-Tai;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-15
    • /
    • 2006
  • To reduce costs and address other practical concern related to architectural lighting, we have been involved in various aspects of advanced daylighting design and control. If we look toward future building trends, we see that the advanced has already successfully deployed such complex lighting control systems. This paper takes a broad view of what advanced manufacturers have done to develop energy efficient lighting control technologies such as sensors, lumen maintenance, time of day scheduling, peak demand reduction and so forth. First of all strategies, daylighting controls would also need to be commissioned to respond to the specific daylighting signature of the zone. To translate the daylight in term of the amount of energy savings, an electric lighting system is designed and automatic on-off control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. The lighting analysis program, Lumen-Micro predicts the optimal layout of conventional fluorescent and incandescent lighting fixtures to meet the designed lighting level and calculates unit power density, which translates the demanded amount of lighting energy.

An Analysis on Applications of Mirror Sunlighting Systems to the Contemporary Buildings with Different Spatial Types (거울형 태양광 채광시스템의 공간유형별 적용현황 분석)

  • Jung, Joo Hee;Lee, Jong Soo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.27-38
    • /
    • 2008
  • Sunlighting offers the high quality of life and has potential to improve environment, economy and human comfort. Especially mirror sunlighting system has competitive power in price, saving energy and solving problems of sunshine lack. This study aims to analyze the adequate applications of mirror type sunlighting systems available in Korea to enhance the living environment. For the purpose, contemporary applications were analyzed by spatial characteristics, size and usage in Germany, Switzerland, Australia, Japan and Korea. As the results, they are being applied for the place with lack of sunshine in housings. For culture complex, they are usually applied for atrium. Nowadays, application of complex systems is increasing to solve sunshine lack and make uniform illuminance. Therefore both aesthetic and technical consideration is needed to apply the advanced mirror sunlighting systems in various spaces.

Sustainable Tall Buildings: Summary of Energy-Efficient Design

  • Kheir Al-Kodmany;Mir M. Ali;Paul J. Armstrong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.107-120
    • /
    • 2023
  • Tall buildings are frequently decried as unsustainable due to their excessive energy usage. Early skyscrapers used natural light and ventilation to facilitate human comfort and applied organic materials such as stone, glass, wood, concrete, and terra cotta for cladding and finishes. With the advent of fluorescent lighting, modern heating, ventilation, air-conditioning (HVAC) systems, and thermally sealed curtain walls, tall office buildings no longer had to rely on natural light and ventilation to provide comfort. Energy efficiency was not a significant factor when the operational costs of buildings were relatively inexpensive. However, today's skyscrapers must become more energy-efficient and sustainable due to energy crises and climate change. This paper highlights vital energy-efficient design principles and demonstrates with illustrative case studies how they are applied to tall buildings in various parts of the world. It shows how sustainable environmental systems do not act alone but are integrated with advanced curtain wall systems, sky gardens, and atria, among others, to regulate and sustain thermal comfort and conserve energy.