• Title/Summary/Keyword: adsorption and desorption

Search Result 672, Processing Time 0.033 seconds

A Study on the Characteristics of Activated Carbons Supported Metal by Microwave Irradiation (마이크로파 조사에 따른 금속이 담지 된 활성탄의 특성 연구)

  • Kim, Sung-Wook;Kim, Jung-Bae;Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.501-508
    • /
    • 2009
  • In this study, the characteristics of granular activated carbon (GAC) supported metal was investigated in an area influenced by flame discharge and temperature variation during irradiating microwave. The modified GAC was formulated by impregnating metal hydroxides of nickel (Ni/GAC), barium (Ba/GAC), copper (Cu/GAC), zinc (Zn/GAC), cobalt (Co/GAC) and lanthanum (La/GAC). Ba/GAC was selected as it showed lack of spark discharge and temperature increasing aspects. Comparison of adsorption and desorption amount of GAC and Ba/GAC showed that adsorption and desorption rate of the GAC were higher than those of Ba/GAC. The results show that the presence of barium can decrease adsorption/desorption rate because of plugging pore of GAC. Toluene regeneration rate of Ba/GAC was better than that of GAC due to barium loading. Finally, GAC with barium can be controled a rapid increasing temperature and spark discharge, increased the regeneration rate of toluene during desorption by irradiating microwave.

Adsorption/desorption of uranium on iron-bearing soil mineral surface

  • Ha, Seonjin;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • v.4 no.2
    • /
    • pp.135-142
    • /
    • 2015
  • In this study, we evaluated the adsorption/desorption of uranium (U) in pure soil environment using continuous column reactor. We additionally investigated the adsorption/desorption mechanism of U on vivianite surface in molecular scale using quantum calculation. We observed that below $0.1{\mu}M$ of U was detected after 20 d from U injection ($1{\mu}M$) in adsorption test. However, all of absorbed U was detached from vivianite surface in 24 h by injection of CARB solution ($1.44{\times}10^{-2}M\;NaHCO_3$ and $2.8{\times}10^{-3}M\;Na_2CO_3$). Based on exchange energy calculation, we found that $UO_2(CO_3)_2{^{2-}}$ and $UO_2(CO_3)_3{^{4-}}$ species have higher repulsive energy than $UO_2(OH)_2$ species. The results obtained from this study could be applied to predict the behavior of uranium in contaminated and remediation sites.

Separation of Vanadium and Tungsten from Simulated Leach Solutions using Anion Exchange Resins (음이온교환 수지를 이용한 바나듐/텅스텐 혼합용액으로부터 바나듐/텅스텐 분리회수에 관한 연구)

  • Jong Hyuk Jeon;Hong In Kim;Jin Young Lee;Rajesh Kumar Jyothi
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.25-35
    • /
    • 2022
  • The adsorption/desorption behavior and separation conditions of vanadium and tungsten ions were investigated using a gel-type anion-exchange resin. In the adsorption experiment with the initial acidity of the solution, the adsorption rate of vanadium was remarkably low in strong acids and bases. Additionally, the adsorption rate of tungsten was low in a strong base. An increase in the reaction temperature increased the adsorption reaction rate and maximum adsorption. The effect of tungsten on the maximum adsorption was minimal. The adsorption isotherms of vanadium and tungsten on the ion-exchange resin were suitable for the Langmuir adsorption isotherms of both the ions. For tungsten, the adsorption isotherms of vanadium and tungsten were polyoxometalate. Both ion-exchange resins were simulated using similar quadratic reaction rate models. Vanadium was desorbed in the aqueous solutions of HCl or NaOH, the desorption characteristics of vanadium and tungsten depended on the desorption solution, and tungsten was desorbed in the aqueous solution of NaOH. It was possible to separate the two ions using the desorption process. The desorption reaction reached equilibrium within 30 min, and more than 90% recovery was possible.

Adsorption/desorption of CO2 on Activated Carbon Fibers Using Electric Swing Adsorption (활성탄소섬유상에서 전기변동법을 이용한 CO2의 흡/탈착)

  • Shim, JaeWoon;Moon, SeungHyun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.432-437
    • /
    • 2005
  • An electric swing adsorption (ESA) process for recovering highly pure $CO_2$ from the mixed gases was tested. In this study, activated carbon fibers were used as an adsorbent. The activated carbon fibers showed fast adsorption rate and the high adsorption capacity for $CO_2$ adsorption under the condition of the ambient pressure. Activated carbon fiber with higher specific surface area was suitable to repeated adsorption-desorption cycle process, showing consistent breakthrough curve. Especially, the regeneration method by vacuum combined with ESA improved the performance of desorption process by an additional 17% regeneration efficiency compared to a vacuum only method, and showed the high regeneration efficiency at comparatively low 7-8 Wh energy.

Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent (유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성)

  • 원정일;김기환;신창섭
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.

A Study on Adsorption of Lead(II) in Wastewater Using Natural Kaolinite (천연 고령토의 폐수 중 납 흡착에 관한 연구)

  • 이종은
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.3
    • /
    • pp.77-86
    • /
    • 1995
  • Lead(II) removal efficiency by natural kaolinite was investigated through laboratory experiments. This study was conducted in two phases-sorption and desorption. In the adsorption study, the influence of sorption kinetics and sorption isotherm and various parameters such as pH, temperature, coexisting other heavy metal ions on the lead adsorption was investigated. And desorption study was carried out in order to find the re-usability of kaolinite as an adsorbent. The results of the study are as follows. 1. Sorption kinetics was investigated under the condition of 2.5 mg/l adsorbent concentration, pH 6.5$\pm$0.05, temperature $30\pm 0.5\circ$C, initial lead(II) concentration 25 mg/l. Adsorption rate was initially rapid and the extent of adsorption arrived at adsorption equilibrium with 73% adsorption efficiency in an hour. 2. The sorption isotherm experiment was made with different initial lead(II) concentration. A linearized Freundlich equation was used to fit the acquired experimental data. As a result, Freundlich constants, the sorption intensity (1/n) was 0.47 and the measure of sorption (k) was 2.44. So, it was concluded that sorption of lead(II) by kaolinite is effective. 3. The effect of pH on lead(II) sorption by kaolinite shows that at a pH of 3, only 6% of the total lead(II) was adsorbed and at a pH 9, 97% of the lead(II) was removed. And the effect of temperature on lead(II) sorption by kaolinite shows that as the temperature increased, the amount of lead(II) sorption per unit weight of kaolinite increased. But the effect was minor (p<0.05). 4. Sorption isotherm of lead coexisting cadmium (II) or zinc (II) was lower than that of lead itself. It was caused by the result of competitive sorption to adsorption site. And there was no difference between the sorption isotherm of cadmium and zinc. 5. In desorption studies, only 5.12% desorption took place in distilled water, while 52.08% in 0.1 N hydrochloric acid. Consequently used kaolinite could be regenerated by hydrochoric acid.

  • PDF

The Interaction of CO and W(111) Surface

  • Lee, S. Y.;Kim, Y. D.;Seo, S. N.;Park, C. Y.;Kwak, H. T.;Boo, J. H.;Lee, S. B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1061-1066
    • /
    • 1999
  • The adsorption of CO on W(111) surface in the range of adsorption temperature between 300 K and 1000 K has been studied using AES, LEED, and TDS in an UHV system. After CO saturation at 300 K, four desorption peaks are observed at temperatures (K) of about 400, 850, 1000, and 1100 in thermal desorption spectra, called as α, β1, β2, and β3 state, respectively. The state was attributed to molecular species of CO, which is well known. Because the CO in βstates (especially the β3 state) is still debated as to whether it is dissociative or non-dissociative, the β3 state is mainly discussed. By using the variation method of heating rate in the thermal desorption spectrometry, the desorption energy and pre-exponential factor for the β3 state are evaluated to be 280 kJ/mol and 1.5×10 12 s-1 , respectively. A lateral interaction energy of 5.7 kJ/mol can also be estimated by Bragg-Williams approximation. To interpret the thermal desorption spectra for the β3 state, moreover, those for the model of a first order and a second order desorption are simulated using quasi-chemical approximation. In this study, a model of lying-down CO species is proposed for the β3 state of CO adsorption.

Behaviors of Desorption Agents During Removal of Cs From Clay Minerals and Actual Soil

  • Park, Chan Woo;Kim, Ilgook;Yoon, In-Ho;Yang, Hee-Man;Seo, Bum-Kyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.39-49
    • /
    • 2021
  • The behaviors of various desorption agents were investigated during the desorption of cesium (Cs) from samples of clay minerals and actual soil. Results showed that polymeric cation exchange agents (polyethyleneimine (PEI)) efficiently desorbed Cs from expandable montmorillonite, whereas acidic desorption solutions containing HCl or PEI removed considerable Cs from hydrobiotite. However, most desorption agents could desorb only 54% of Cs from illite because of Cs's specific adsorption to selective adsorption sites. Cs desorption from an actual soil sample containing Cs-selective clay mineral illite (< 200 ㎛) and extracted from near South Korea's Kori Nuclear Power Plant was also investigated. Considerable adsorbed 137Cs was expected to be located at Cs-selective sites when the 137Cs loading was much lower than the sample's cation exchange capacity. At this low 137Cs loading, the total Cs amount desorbed by repeated washing varied by desorption agent in the order HCl > PEI > NH4+, and the highest Cs desorption amount achieved using HCl was 83%. Unlike other desorption agents with only cation exchange capabilities, HCl can attack minerals and induce dissolution of metallic elements. HCl's ability to both alter minerals and induce H+/Cs+ ion exchange is expected to promote Cs desorption from actual soil samples.

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

Organic Pollutant Transport in Unsaturated Porous Media by Atmospheric Breathing Process(II) Dispersion Coefficient (불포화토양에서 확산에 의한 유기오염물질의 이동)

  • 구자공;황종혁
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.79-82
    • /
    • 1997
  • 토양내에서 오염유기물질이 불포화토양내에 유입될 때의 dispersion coefficient를 adsorption과 desorption과정에 대해 알아보았다. apparent dispersion coefficient를 측정하기 위해 일상적인 상대습도(46%)조건에서 parametric analysis를 행하였다. 실험에 사용된 토양은 fine sand와 silt-clay혼합시료였고, 흐름방향은 상향과 하향으로 하였다. 그리고, Freon gas를adsorbing solute로 사용하였다. 오염물질로는 DCM, TCE, DCB를 사용하였다. 분석을 위해서 linear와 probability scale의 breakthrough curve를 사용하였다. 공기에서의 diffusion coefficient의 예측을 위하여 Graham's law를 계산에 사용하였고, DCM diffusion coefficient는 0.098$\textrm{cm}^2$/s로 계산되었다. 연구결과, adsorption과 desorption의 속도는 차이가 있는 것으로 나타났으며, diffusion이 flow regime을 좌우하는 것으로 나타났다. 그리고, desorption에서의 D$^{a}$ D$^{o}$ 는 1보다 클수도 있다. 또한, dispersion은 silt-clay혼합시료에서의 속도와 함께 증가한다. dispersion은 Freon의 sorption방향에 크게 의존한다.

  • PDF