• Title/Summary/Keyword: adjustable

Search Result 846, Processing Time 0.025 seconds

Design and Control of Adjustable Turn-ratio LLC Converter for High-efficiency Operation of Wired/Wireless Integrated Charging System for Electric Vehicles (전기자동차용 유·무선 통합 충전 시스템의 고효율 동작을 위한 권선비 가변형 LLC 컨버터 설계 및 제어 방안)

  • Jo, Hyeon-Woo;Sim, Dong-Hyeon;Lee, Ju-A;Son, Won-Jin;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.237-246
    • /
    • 2022
  • This paper proposes a method to adjust the turn ratio of a transformer for the high-efficiency operation of an LLC converter with a wide input range in a wired/wireless integrated charging system for electric vehicles. The characteristics of the inductive power transfer converter in the integrated charging system are analyzed to design the LLC converter, and the DC-link voltage range is derived. The aspect of voltage gain following each parameter of the LLC converter is analyzed, and the resonant network and transformer are designed. Based on the designed parameters, the feasibility of the design and control method is verified by implementing the operation of the LLC converter according to the DC-link and battery voltages.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Ergonomic Design of Office Chair (사무실 의자의 인간공학적 디자인)

  • 곽원모;홍성수;정석길;이상도;이동춘;윤훈용
    • Archives of design research
    • /
    • v.12 no.3
    • /
    • pp.73-80
    • /
    • 1999
  • Many domestic users complain about severe pain to the waist, neck, and shoulder as well as work performance because the domestic chair design was developed with western anthropometry dimension and design criteria. Ergonomic design standards are needed for office chair design to reduce stress and poor physical posture for various user body types. In this study, we have suggested design dimensions recommended from previous studies and Korean anthropometry data. We also have reviewed users' preference dimension through measured subjects and analyzed differences between users' preference dimension and the previous design criteria to verify physical appropriateness. We evaluated general office chairs and adjustable chairs which can adjust to fit each person. we also analyzed how each design dimension was reached and affected the human body by evaluation of physical discomfort and comfort. We have found seat height is very important in a workstation. If the seat height is high, it effects the thigh. If width, height, and angle of the backrest are wrong, fatigue to the shoulder, neck, and waist, etc.. As a result of this experiment, we suggested that the height of a seat for Koreans be 425mm for the fixed type and 365-484mm for the adjustable type. Also other design recommendations were suggested in the thesis. In conclusion, our research will be very important in the database because it provides adjustable ranges to fit user's body types in the various design fields.

  • PDF

Frequency Adjustable Dual Composite Right/Left Handed Transmission Lines (주파수 가변성을 갖는 D-CRLH 전송 선로)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1375-1382
    • /
    • 2008
  • Frequency adjustable D-CRLH(dual-composite right/left handed) transmission lines, which solve the problem of design complexity and uncontrolled frequency of the existing structures, are proposed in this paper. The first design(type I), consisting of defected ground structure(DGS), island pattern in DGS, fixed stub and varactor diodes, controls $C_L$ in the parallel resonant circuit, while the second structure(type 2) composed of fixed DGS, shunt stub and diode adjusts $C_R$ in the series resonant circuit. The dual band frequency points which correspond to the meaningful electrical length of +/-90 degree in the RH/LH region are adjustable according to the bias voltage. The measurement shows that the LH frequency point which has -90 degree of electrical length are adjusted over $4.22{\sim}5.39\;GHz$ and $4.21{\sim}5.05\;GHz$ for type 1 and type 2, respectively, under $1{\sim}12\;V$ of bias voltage. In addition, the frequency Woo where RH turns over LH is controled over $3.26{\sim}4.22\;GHz$ for type 2 with the same bias condition.

The Development of Height Adjustable Steel Manhole cover (높이조절이 가능한 강재 맨홀뚜껑의 개발)

  • Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.581-586
    • /
    • 2018
  • Cast iron manhole lids cause environmental pollution during the manufacturing process, and the work environment is very poor. In addition, if the height of the manhole cover does not match the height of the road surface, it causes considerable inconvenience and safety problems. This study proposes a height - adjustable steel manhole cover that can replace cast iron manhole covers and easily match the road surface with the upper surface of the manhole cover. Structural analysis was performed to grasp the design variable of the structure of the manhole cover, satisfying the required quality performance. To fabricate a manhole cover that satisfies the required load capacity, the optimal design for the U-shaped reinforcement structure was made. The cylindrical shape of the height adjustment part and the low frame were formed by bending the steel sheet into a circular shape and then welding. Reinforcing bars were also made by bending a steel plate. The height adjustment groove was machined by a CNC milling machine. Four prototypes were fabricated and a load bearing test was carried out, and new manhole cover was made reflecting results of the test. In the load bearing test, there was no breakage of the welded part, and deformation occurred mainly at the contact area between the groove and gusset plate. Deformation of 1 to 2.7mm occurred due to a load of 450kN. On the other hand, after removing the load, there was almost no residual deformation, and the load bearing evaluation was judged to be satisfactory because the manhole cover could be disassembled and reassembled.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Development of an Adjustable Beam Bracket for Beam Table Form - Conceptual Design and Structural Stability Analysis - (보 테이블 폼 전용 가변형 보 브라켓 개발 - 개념 디자인 제시 및 구조적 안정성 분석 -)

  • Hong, Yu-Na;Yeom, Dong-Jun;Yoo, Hyun-Seok;Kim, Young Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.5
    • /
    • pp.70-80
    • /
    • 2018
  • Recently, the construction industry has lively utilized system forms to improve the work productivity and safety of form work, and the beam table form is one of them. However, the beam table form is used limitedly for the construction of buildings where the same beam size is applied to every floor. To make it possible to apply the beam table form to a building where different beam sizes are designed according to the uses of floors, it was analyzed that among the components of the beam table form, the beam bracket, should be able to flexible adjust the size of the beam form only with simple operation. Therefore, the purpose of this study is to propose the conceptual design of "an adjustable beam bracket for beam table form" that allows the adjustment of beam form size with simple operation and has excellent applicability to construction sites as well. In case this study's conceptual design of adjustable beam bracket for beam table form is fabricated into a real thing, it is expected that the beam table form will be applicable to even buildings where different beam sizes are designed according to the uses of floors, thereby contributing to the improvement in the work productivity and safety of form work.

Design and Evaluation of Pulsed Electromagnetic Field Stimulation Parameter Variable System for Cell and Animal Models (세포 및 동물모델용 펄스형 전자기장 자극 파라미터 가변장치 설계 및 평가)

  • Lee, Jawoo;Park, Changsoon;Kim, Junyoung;Lee, Yongheum
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • An electromagnetic generator with variable stimulation parameters is required to conduct basic research on magnetic flux density and frequency for pulsed electromagnetic fields (PEMFs). In this study, we design an electromagnetic generator that can conduct basic research by providing parameters optimized for cell and animal experimental conditions through adjustable stimulation parameters. The magnetic core was selected as a solenoid capable of uniform and stable electromagnetic stimulation. The solenoid was designed in consideration of the experimental mouse and cell culture dish insertion. A voltage and current adjustable power supply for variable magnetic flux density was designed. The system was designed to be adjustable in frequency and pulse width and to enable 3-channel output. The reliability of the system and solenoid was evaluated through magnetic flux density, frequency, and pulse width measurements. The measured magnetic flux density was expressed as an image and qualitatively observed. Based on the acquired image, the stimulation area according to the magnetic flux density decrease rate was extracted. The PEMF frequency and pulse width error rates were presented as mean ± SD, and were confirmed to be 0.0928 ± 0.0934% and 0.529 ± 0.527%, respectively. The magnetic flux density decreased as the distance from the center of the solenoid increased, and decreased sharply from 60 mm or more. The length of the magnetic stimulation area according to the degree of magnetic flux density decrease was obtained through the magnetic flux density image. A PEMF generator and stimulation parameter control system suitable for cell and animal models were designed, and system reliability was evaluated.

A Low-Noise High Performance Amplifier for Low Input Signals (저입력신호를 위한 저잡음 고성능 증폭기)

  • 이대영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.4
    • /
    • pp.17-24
    • /
    • 1972
  • A simply constructed and inexpensive amplifier that exhibits unusually low noise is studied. The high-performance differential amplifier combines high input impedence, adjustable gain, low in put noise and low output impedance. The amplifier is particularly useful in applications which call for large amplificaions of very low level signals.

  • PDF

High-efficiency BIRA for embedded memories with a high repair rate and low area overhead

  • Lee, Joo-Hwan;Park, Ki-Hyun;Kang, Sung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.266-269
    • /
    • 2012
  • High-efficiency built-in redundancy analysis (BIRA) is presented. The proposed BIRA uses three techniques to achieve a high repair rate using spare mapping registers with adjustable fault tags to reduce area overhead. Simulation results show that the proposed BIRA is a reasonable solution for embedded memories.