• Title/Summary/Keyword: adhesive material

Search Result 746, Processing Time 0.023 seconds

A Study on Fracture Characteristics in Opening Mode of a DCB Specimen Using a Lightweight Material (경량 재료를 이용한 DCB 시험편의 열림 모드에서의 파손 특성에 관한 연구)

  • Kim, Jae-Won;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2021
  • Recently, many structures using lightweight materials have been developed. This study was conducted by using Al6061-T6 and carbon fiber reinforced plastic (CFRP), two common lightweight materials. In addition, the failure characteristics of an interface bonded between a single material and a heterogeneous bonding material were analyzed. The specimens bonded with CFRP and Al6061-T6 were utilized by the combination of the heterogeneous bonding material. The specimens had a double cantilevered shape and the bonding between the materials was achieved by applying a structural adhesive. The experiments were conducted in opening mode: the lower part of the samples was fixed, while their upper part was subjected to a forced displacement of 3 mm/min by using a tensile tester. Under the tested amount of strength, energy release rate, and considering the specimens' fracture characteristics in opening mode, the specimen "CFRP-Al" presented the maximum stress, followed by "Al" and "CFRP". We can hence conclude that the inhomogeneous material "CFRP-Al" is useful for the construction of lightweight structures bonded with structural adhesive.

A Study for Selection and Field Applicability of Asphalt Precast Pothole Repair Materials (아스팔트 프리캐스트 포트홀 보수재료의 선정과 현장 적용성에 관한 연구)

  • Kim, Jincheol;Bae, Sungho;Lee, Jinho;Yang, Jaebong;Kim, Jiwon
    • International Journal of Highway Engineering
    • /
    • v.16 no.4
    • /
    • pp.21-33
    • /
    • 2014
  • PURPOSES: The purpose of this study was to break away from the workforce method using cold-mix asphalt mixtures and has a constant quality and has develop repair materials of pre-production asphalt-precast types. METHODS: The selection of the repair material was determined as the results obtained through physical properties of materials and the field applicability. In case of repair materials, values obtained through Marshall stability test & the dynamic stability test & retained stability test as well as the site conditions was considered. In case of adhesive, test results were obtained through examination of the bond strength(tensile, shear) and the field applicability of the adhesive was examined through combined specimens to simulate field applications. RESULTS : According to the results of laboratory tests, in the case of repair materials, Marshall stability and dynamic stability, retained stability of cold-mix reaction type asphalt mixture is the highest. In the case of adhesive, two-component epoxy-urea has a very high bonding strength(tensile, shear) was most excellent. According to the results of field tests, when epoxy-urea was excellent workability. Also, the repair body through actual mock-up test did not occur large deformation and fracture after 12 months. CONCLUSIONS : A suitable repair material is cold-mix reaction type mixture of asphalt-precast, a suitable adhesive is a two-component epoxy-urea.

Effect Evaluation of Hole Defects in Adhesive on SIF of Interface Crack (접착층내 결함이 계면균열의 응력확대계수에 미치는 영향 평가)

  • Hyun, Cheol-Seung;Heo, Sung-Pil;Yang, Won-Ho;Ryu, Myung-Hae
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.299-303
    • /
    • 2001
  • Adherend-adhesive interface failure will occur on a macroscale when surface preparation or material quality are poor. It is well known that the stress singularity occurs at the edges of interface between the adhernds and the adhesive, and that crack will initiate from these positions. Also if bubbles are created and remained in the adhesive layer during the bonding process, the stress concentrates around these hole defects. In this paper, the effects of the hole defects on the SIF of interface crack were examined. From results, SIF increased with the hole defects near the interface crack and increased with an decreae in the upper adherend thickness, an increase in the center adhesive thickness.

  • PDF

Variation of fracture strength of adhesive joint according to the operating temperature (사용환경온도에 따른 접착이음의 인장전단강도 변화)

  • Kim, J.Y.;Lee, C.J.;Lee, S.K.;Park, G.W.;Jung, B.H.;Schafer, H.;Kim, B.M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.517-520
    • /
    • 2008
  • Recently, use of adhesive bonding technology is increased to achieve the multi-material design for lightweight structure in automobile industry. In this paper, the fracture strength of adhesive has been studied with the single lap shear test conducted at different temperatures. The joint specimens are made from Al 5052 and SPRC 440 bonded with structural epoxy adhesive. The operating temperature has been considered up to $150[^{\circ}C]$ and the single lap shear test has been conducted with 5mm/min tensile rate. Fracture strength of adhesive bonded joint has been decreased with increase of operating temperature. The fracture strength at the $100[^{\circ}C]$ was shown about half of that at room temperature.

  • PDF

A Study on Strength Evaluation of Adhesive Joints(1st Report, Stress Analysis and Fracture Strength of Adhesive Single-Lap Joint) (접착이음의 강도평가에 관한 연구 (제1보 겹치기 접착이음의 응력해석과 파괴강도))

  • 정남용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.667-674
    • /
    • 1992
  • Recently advantages in composite and light weight material technique have led to the increased use of structural adhesives in various industries. In spite of such wide application of the adhesive joints, the evaluation method of fracture strength and design methodology of them, have not been established. In this study finite element method, theoretical and experimental analyses were investigated according to changes of lap length and adhesive for adhesive single-lap joint. As the results, the strength evaluation of adhesive joint by conventional nominal stress, was pointed out inadequate strength evaluation and design method regardless stress singularity, stress distribution and crack propagation in its adhesive layer. Also, it was examined the problems to apply fracture mechanics by means of static and fatigue test.

Numerical analysis of the combined aging and fillet effect of the adhesive on the mechanical behavior of a single lap joint of type Aluminum/Aluminum

  • Medjdoub, S.M.;Madani, K.;Rezgani, L.;Mallarino, S.;Touzain, S.;Campilho, R.D.S.G.
    • Structural Engineering and Mechanics
    • /
    • v.83 no.5
    • /
    • pp.693-707
    • /
    • 2022
  • Bonded joints have proven their performance against conventional joining processes such as welding, riveting and bolting. The single-lap joint is the most widely used to characterize adhesive joints in tensile-shear loadings. However, the high stress concentrations in the adhesive joint due to the non-linearity of the applied loads generate a bending moment in the joint, resulting in high stresses at the adhesive edges. Geometric optimization of the bonded joint to reduce this high stress concentration prompted various researchers to perform geometric modifications of the adhesive and adherends at their free edges. Modifying both edges of the adhesive (spew) and the adherends (bevel) has proven to be an effective solution to reduce stresses at both edges and improve stress transfer at the inner part of the adhesive layer. The majority of research aimed at improving the geometry of the plate and adhesive edges has not considered the effect of temperature and water absorption in evaluating the strength of the joint. The objective of this work is to analyze, by the finite element method, the stress distribution in an adhesive joint between two 2024-T3 aluminum plates. The effects of the adhesive fillet and adherend bevel on the bonded joint stresses were taken into account. On the other hand, degradation of the mechanical properties of the adhesive following its exposure to moisture and temperature was found. The results clearly showed that the modification of the edges of the adhesive and of the bonding agent have an important role in the durability of the bond. Although the modification of the adhesive and bonding edges significantly improves the joint strength, the simultaneous exposure of the joint to temperature and moisture generates high stress concentrations in the adhesive joint that, in most cases, can easily reach the failure point of the material even at low applied stresses.

Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

  • Komurcuoglu, Meltem Bektas;Sagirkaya, Elcin;Tulga, Ayca
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.439-446
    • /
    • 2017
  • PURPOSE. To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens ($4{\times}1.2{\times}12mm$) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (P<.001). For LDC, AS surface treatment showed the highest FPBS results ($100.31{\pm}10.7MPa$) and the lowest values were obtained in RNC ($23.63{\pm}9.0MPa$) for control group. SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. CONCLUSION. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

Failure Mode and Strength of Unidirectional Composite Single Lap Bonded Joints I. Experiments (일방향 복합재료 Single Lap접합 조인트의 파손 모드 및 강도 I. 실험)

  • Kim Kwang-Soo;Yoo Jae-Seok;An Jae-Mo;Jang Young-Soon
    • Composites Research
    • /
    • v.17 no.6
    • /
    • pp.14-21
    • /
    • 2004
  • Failure process, mode and strength of unidirectional composite single lap bonded joints were investigated experimentally with respect to bonding methods, those are, co-curing with and without adhesive and secondary bonding. The co-cured joint specimens without adhesive had the largest failure strength. Progressive failures along the adhesive layer occurred in the secondary bonded specimens. In the co-cured specimens with adhesive film which had better material strength and adhesion performance, delamination failure occurred and the joint strengths were less than those of secondary bonded specimens. Delamination failure did not occur in the secondary bonded specimens because of earlier crack growth and progressive failure in the adhesive layer. Therefore, failure strength of composite bonded Joints were not always proportionate to material strength and adhesion performance of the adhesive due to the weakness of delamination in composite materials. The effects of surface roughness, bondline thickness and fillets were also studied on secondary bonded specimens.

The Effects of the Combination of Calcium Carbonate and Fibrin Adhesive on the Periodontal Regeneration of Class II Furcation Defect in Dogs (Calcium carbonate와 fibrin adhesive의 병용이 성견 2급 치근 분지부 치주조직 재생에 미치는 영향)

  • Seo, Eun-Pyo;Chung, Hyun-Ju;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.229-242
    • /
    • 2000
  • The purpose of this study was to evaluate the effect of fibrin tissue adhesive and porous resorbable calcium carbonate on the periodontal regeneration of the class II furcation defect in dogs. Class II furcation defect was surgically created on the second, third, and fourth premolars bilaterally in the mandibles of six mongrel dogs. The experimental sites were divided into four groups according to the treatment modalities: Control-surgical debridement only; Group I-calcium carbonate grafting; Group II-application of fibrin adhesive only; Group III-application of fibrin adhesive after calcium carbonate grafting. The animals were sacrificed at the 2, 4, and 12 weeks after periodontal surgery and the decalcified specimens were prepared for histological and histometrical examination. The results are as follows : Clinically, there were no inflammatory response in all groups after 2, 4, 12 weeks. In the Control group, junctional epithelium was grown downward to the reference notch. In Group I, graft materials were exfoliated from the defect throughout the experimenta periods andnew bone was seen in the notch area at 4 and 12 week specimens. In Group II, fibrin adhesive was absorbed at 2 week specimens, and connective tissue attachment increased than that of control group. New cementum and new bone were seen above the notch area. In Group III, the graft material was maintained in the defect throughout the experimental period and inducing the amount of periodontal tissue regeneration was higher than other groups. These results suggest that the use of fibrin tissue adhesive in conjunction with porous resorbable calcium carbonate would improves the stability of graft material and inhibit the epithelial down growth and make it be a feasible method for periodontal regeneration.

  • PDF

Use Biologic Fibrin Adhesive in Otologic Surgery : Compared with Ammonium Sulfate Fibrin Adhesive and Tisseel$^{(R)}$ (중이수술에 인체에서 추출한 Fibrin 접착제의 이용 : Ammonium Sulfate fibrin 접착제와 Tisseel$^{(R)}$의 비교)

  • Lee, Hyung-Chul;Yang, Mi-Gyeung;Park, Mun-Heum
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.127-135
    • /
    • 1991
  • Successful middle ear surgery requires the availability of al safe, effective bonding material. Side effect caused by synthetic materials have led to the use of biologic adhesive. However, they carry the risk of transmission of infectious diseases if they are prepared from pooled human blood. The adhesive strength of ammonium sulfate fibrin adhesive produce an adhesive strength that is half that of the homologous commercial product. It is, however, good enough for use in several otolaryngological operations, tympanoplasty, facial nerve repair, reconstruction of ossicles, reconstruction of posterior wall of ear canal and obliteration of frontal sinus and mastoid antrum using bone dust.

  • PDF