• 제목/요약/키워드: adhesion materials

검색결과 1,678건 처리시간 0.031초

Adhesion of Cu/Interlayer/Polyimide Flexible Copper Clad Laminate Depending on the Ni-Cr-X Interlayers

  • Kim, Si Myeong;Jo, Yoo Shin;Kim, Sung June;Kim, Sang Ho
    • 한국표면공학회지
    • /
    • 제50권3호
    • /
    • pp.164-169
    • /
    • 2017
  • Ni-Cr-X ternary interlayers were investigated to improve the adhesion of Cu/Ni-Cr/Polyimide flexible copper clad laminates. The ternary compounds are sputtered Ni-Cr-X films (where X is one of Nb, V, Mo, or Ti), and the effect of third elements on the adhesion was evaluated and investigated chemically and mechanically. The feel strength was higher in the order of Ni-Cr-Nb > Ni-Cr-V > Ni-Cr > Ni-Cr-Mo > Ni-Cr-Ti. Nb, which has a comparable standard electrode potential to Cr, increased the adhesion, while Ti, with a low standard electrode potential, degraded the adhesion. The Ni-Cr-Nb interlayer was amorphous, while Ni-Cr-Ti was partially crystalline. The similar morphology structure of the Ni-Cr-Nb interlayer with polyimide resulted in a better adhesion.

Variation in adhesion of Streptococcus mutans and Porphyromonas gingivalis in saliva-derived biofilms on raw materials of orthodontic brackets

  • Park, So-Hyun;Kim, Kyungsun;Cho, Soha;Chung, Dong-Hwa;Ahn, Sug-Joon
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.278-286
    • /
    • 2022
  • Objective: To evaluate differences in the adhesion levels of the most common oral pathogens, Streptococcus mutans and Porphyromonas gingivalis, in human saliva-derived microcosm biofilms with respect to time and raw materials of orthodontic brackets. Methods: The samples were classified into three groups of bracket materials: 1) monocrystalline alumina ceramic (CR), 2) stainless steel metal (SS), and 3) polycarbonate plastic (PL), and a hydroxyapatite (HA) group was used to mimic the enamel surface. Saliva was collected from a healthy donor, and saliva-derived biofilms were grown on each sample. A real-time polymerase chain reaction was performed to quantitatively evaluate differences in the attachment levels of total bacteria, S. mutans and P. gingivalis at days 1 and 4. Results: Adhesion of S. mutans and P. gingivalis to CR and HA was higher than the other bracket materials (SS = PL < CR = HA). Total bacteria demonstrated higher adhesion to HA than to bracket materials, but no significant differences in adhesion were observed among the bracket materials (CR = SS = PL < HA). From days 1 to 4, the adhesion of P. gingivalis decreased, while that of S. mutans and total bacteria increased, regardless of material type. Conclusions: The higher adhesion of oral pathogens, such as S. mutans and P. gingivalis to CR suggests that the use of CR brackets possibly facilitates gingival inflammation and enamel decalcification during orthodontic treatment.

광개시제의 함량에 따른 UV 경화형 분체도료의 물리적 특성 (Physical Properties of UV-Curable Powder Coatings with Different Photoinitiator Contents)

  • 문제익;최재훈;황현득;김현중;김남홍
    • 접착 및 계면
    • /
    • 제9권2호
    • /
    • pp.32-37
    • /
    • 2008
  • 광개시제 함량이 0.5 wt%, 1 wt%, 2 wt%인 UV 경화형 분체도료를 배합하고 낮은 온도에서도 용융되는 수지를 선택하여 열민감성 기재에 적용이 가능함을 알아보았다. 열민감성 기재로는 PVC와 목재제품(MDF, 합판 등)을 선택하여 표면경도, 광택, 부착력을 통해서 기재와의 상관관계를 알아보았다. 광개시제 양이 증가할수록 가교밀도가 증가하여 도막이 brittle해지는 경향을 보였고, 그에 따라 부착력이 감소하였다. 열민감성 기재에 적용한 결과, 표면경도는 기재에 영향을 받지 않았지만 광택은 기재에 따라서 차이가 나타났다. 그리고 UV 경화형 분체도료의 부착력은 열민감성 기재에 적용하기에 충분하였다. 본 연구 결과, UV 경화형 분체도료에서 광개시제 함량이 중요한 인자이며 열민감성 기재에 적용이 가능함을 확인하였다.

  • PDF

경피흡수제제용 점착제 (Pressure Sensitive Adhesives for Transdermal Drug Delivery System(TDDS))

  • 김범준;김현중
    • 접착 및 계면
    • /
    • 제4권1호
    • /
    • pp.43-50
    • /
    • 2003
  • 점착제는 경피흡수제제(transdermal drug delivery system, TDDS)의 중요한 구성요소 중의 하나이다. TDDS용 점착제는 일반적인 점착제의 역할 외에도 부착되는 피부에 적합해야 하고, 이것에 포함되는 약물 및 첨가제들과 양립하면서 약물의 전달을 효과적으로 지속해야한다. 본 총설에서는 흔히 사용되는 TDDS용 점착제인 polyisobutylenes, polyacrylates, silicones와 최근에 개발된 제품들을 소개한다.

  • PDF

Adhesion Strength and Other Mechanical Properties of SBR Modified Concrete

  • Chmielewska, Bogumila
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.3-8
    • /
    • 2008
  • Polymer-cement composites are known repair materials. The aim of this work is to investigate the influence of various amount of dispersion of carboxylated styrene-butadience copolymer on the selected mechanical properties of polymer-cement concrete (PCC) and on its adhesion to ordinary concrete. The compressive, flexural and tensile strengths as well as frost resistance and fracture resistance of the composites are tested. Adhesion strength of PCC to ordinary concrete, as one of most important performance of good repair material is evaluated and analyzed using three test methods. The results obtained in standard pull-off test are compared with the two other tests. The first one, which is an adaptation of WST (wedge splitting test) characterizes crack propagation in the plane of bond created during repair. In the second test the resistance to shear is a measure of adhesion strength.

크롬/폴리이미드의 접착력에 미치는 폴리이미드 표면의 플라즈마 처리의 효과 (The effects of plasma treatment of polyimide surface on the adhesion of chromium/polyimide)

  • 정태경;김영호;유진
    • 한국표면공학회지
    • /
    • 제26권2호
    • /
    • pp.71-81
    • /
    • 1993
  • Thed effects of Ar or Oxygen RF plasma treatment on the adhesion behavior of Cr films to polyimide sub-strates have been investigated by using SEM, XRD, AES, and $90^{\circ}$peel test. By applying RF plasma treatment of the polyimide surface prior to metal deposition, the peel adhesion strength of Cu/Cr films sputtered onto the fully cured BPDA-PDA polyimide was highly increased from about 3g/mm to 90 ~ 100g/mm. Improved peel adhesion strength of Cr/polyimide interfaces due to RF plasma treatment was attributed to the contributions from surface cleaning, Cr-polyimide bonding at the interface, and force required for plastic deformation of the film. While the surface topology change of the polyimide caused by RF plasma treatment makes a little contri-bution to the improved adhesion.

  • PDF

접착층을 고려한 플라즈모닉 금 나노 디스크의 광산란 특성 (Effect of Adhesion layer on the Optical Scattering Properties of Plasmonic Au Nanodisc)

  • 김주영;조규만;이경석
    • 대한금속재료학회지
    • /
    • 제46권7호
    • /
    • pp.464-470
    • /
    • 2008
  • Metallic nanostructures have great potential for bio-chemical sensor applications due to the excitation of localized surface plasmon and its sensitive response to environmental change. Unlike the commonly explored absorption-based sensing, the optical scattering provides single particle detection scheme. For the localized surface plasmon resonance spectroscopy, the metallic nanostructures with controlled shape and size have been usually fabricated on adhesion-layer pre-coated transparent glass substrates. In this study, we calculated the optical scattering properties of plasmonic Au nanodisc using a discrete dipole approximation method and analyzed the effect of adhesion layer on them. Our result also indicates that there is a trade-off between the surface plasmon damping and the capability of supporting nanostructures in determining the optimal thickness of adhesion layer. Marginal thickness of Ti adhesion layer for supporting Au nanostructures fabricated on a silica glass substrate was experimentally analyzed by an adhesion strength test using a nano-indentation technique.

멜라민 첨가 순서에 따른 UMF 접착제의 경화거동과 접착력의 영향 (Curing Behavior and Adhesion Performance of Urea-Melamine-Formaldehyde (UMF) Resin by Staged Addition of Melamine)

  • ;엄영근;이영규;임동혁;이병호;김현중
    • 접착 및 계면
    • /
    • 제10권2호
    • /
    • pp.84-89
    • /
    • 2009
  • The objective of this research was to investigate the curing behavior and adhesion performance of urea-melamine-formaldehyde (UMF) resin for the four types of UMF-1, UMF-2, UMF-3, and UMF-4 which synthesized by the staged addition of melamine. Also, various network structures of these resin types were discussed based on their different curing behavior and adhesion performance. The curing behavior was evaluated by DMTA and thermal stability was checked by TGA. Adhesion performance was evaluated by dry and wet shear strengths and the pH value of each cured resin was checked to see its effect on the adhesion performance. The results indicated that the UMF-1 resin type by the addition of melamine initially with the urea and formaldehyde at the same F/(U+M) rate showed the lowest thermal stability, rigidity (${\Delta}E^{\prime}$), temperature of tan ${\delta}$ maximum ($T_{tan}\;_{\delta}$), and wet shear strength, and pH value of cured resin. In wet shear strength, however, the UMF-4 resin type appears to be slightly higher than UMF-1 resin type.

  • PDF

생체 적합성 재료를 이용한 수술후 유착 방지막의 제작과 응용 (Fabrication and application of post surgical anti-adhesion barrier using bio-compatible materials)

  • 박석희;김효찬;양동열;김택경;박태관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.203-204
    • /
    • 2006
  • Studies on some biodegradable polymers and other materials such as hydrogels have shown the promising potential for a variety of surgical applications. Postoperative adhesion caused by the natural consequence of surgical wound healing results in problems of the repeated surgery. Recently, scientists have developed absorbable anti-adhesion barriers that can protect a tissue from adhesion in case they are in use; however, they are dissolved when no longer needed. Although these approaches have been attempted to fulfill the criteria for adhesion prevention, none can perfectly prevent adhesions in all situations. Overall of this work, a new method to fabricate an anti-adhesion membrane using biodegradable polymer and hydrogel has been developed. The ideal barrier for preventing postoperative adhesion would have the following properties; it should be (i) resorbable (ii) non-reactive (iii) easy to apply (iv) capable of being fixed in position. In order to fulfill these properties, we adopted solid freeform fabrication method combined with surface modification which includes the hydrogel coating, therefore, inner or outer structure can be controlled and the property of anti adhesion can be improved.