• Title/Summary/Keyword: actual structures

Search Result 1,101, Processing Time 0.025 seconds

Automatic crack detection of dam concrete structures based on deep learning

  • Zongjie Lv;Jinzhang Tian;Yantao Zhu;Yangtao Li
    • Computers and Concrete
    • /
    • v.32 no.6
    • /
    • pp.615-623
    • /
    • 2023
  • Crack detection is an essential method to ensure the safety of dam concrete structures. Low-quality crack images of dam concrete structures limit the application of neural network methods in crack detection. This research proposes a modified attentional mechanism model to reduce the disturbance caused by uneven light, shadow, and water spots in crack images. Also, the focal loss function solves the small ratio of crack information. The dataset collects from the network, laboratory and actual inspection dataset of dam concrete structures. This research proposes a novel method for crack detection of dam concrete structures based on the U-Net neural network, namely AF-UNet. A mutual comparison of OTSU, Canny, region growing, DeepLab V3+, SegFormer, U-Net, and AF-UNet (proposed) verified the detection accuracy. A binocular camera detects cracks in the experimental scene. The smallest measurement width of the system is 0.27 mm. The potential goal is to achieve real-time detection and localization of cracks in dam concrete structures.

Propose an Improvement of Checklist for Actual Condition Survey for Designation of Class-lll Facilitie (제3종시설물 지정을 위한 실태조사 체크리스트 개선방안)

  • Yoon, Ji-Ho;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.100-101
    • /
    • 2021
  • Facilities with high risk of a disaster or requiring continuous safety management are designated as class-III facility. In order to designate a class-III facility, it is evaluated based on the safety status of the facility, the risk to the building users, and the number of years elapsed of the facility, etc. and this shall be referred to the actual condition survey for the designation of a class-III facility. In the actual condition survey conducted to designate the safety status is calculated by the checklist based on the evaluation scores consisting of five stages each item, and is evaluated in three stages by 'good', 'careful observation', and 'designated review' through the average of the combined scores. Currently, the actual condition survey being conducted applies only structural stability, and the risk factors such as damage to the finish, the risk of cracking, and the type and weight of major structures are not included in the checklist for the actual condition survey, so even if experts think it is dangerous, scores cannot be reflected. Therefore, this study aims to analyze the problems of checklist of the actual condition survey for the designation of class-III facility and to propose an improvement plan for the checklist for the actual condition survey.

  • PDF

Structural damage identification of plates based on modal data using 2D discrete wavelet transform

  • Bagheri, A.;Ghodrati Amiri, G.;Khorasani, M.;Bakhshi, H.
    • Structural Engineering and Mechanics
    • /
    • v.40 no.1
    • /
    • pp.13-28
    • /
    • 2011
  • An effective method for detection linear flaws in plate structures via two-dimensional discrete wavelet transform is proposed in this study. The proposed method was applied to a four-fixed supported rectangular plate containing damage with arbitrary length, depth and location. Numerical results identifying the damage location are compared with the actual results to demonstrate the effectiveness of the proposed method. Also, a wavelet-based method presented for de-noising of mode shape of plate. Finally, the performance of the proposed method for de-noising and damage identification was verified using experimental data. Comparison between the location detected by the proposed method, and the plate's actual damage location revealed that the methodology can be used as an accessible and effective technique for damage identification of actual plate structures.

The optimisation method of the elastic-plastic spatial grid structures

  • Karczewski, Jan
    • Steel and Composite Structures
    • /
    • v.3 no.4
    • /
    • pp.277-287
    • /
    • 2003
  • The low boundary of load carrying capacity of the elastic-plastic spatial grid structures depend on numerous values and their variability assumed in designing process. Analysed influence all this values in searching for optimal variant of the structure lead to too great problem even taking into consideration actual computational power we have in disposal. Therefore one can take only a few values which have greatest influence on the optimal choice. In optimal analysis of the elastic-plastic spatial grid structures the previously proposed method with subsequent modification (Karczewski 1980), (Karczewski, Barszcz and Donten 1996), (Karczewski and Donten 2001) as well as computer program which was worked out by Donten K. to make possible practical utilisation this method was employed. The paper deal with evaluation of influence dimensions of particular values for choice of optimal variant of the structure. One among this values is distribution of the struts in the structure.

A Case Study on the Method of High-rise Wall in Rammed Earth Construction (고층형 흙다짐 공법의 사례 연구)

  • Lee, JongKook;Kim, HoChun;Lee, SangWon
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.85-91
    • /
    • 2008
  • We intends to understand the rammed earth method and suggest the possibilities of adoption on high-rise rammed earth structures through the case study on the method. The rammed earth construction has been regarded as one of the solutions in the modern environmental-friendly construction field, thus according to such trend, this study tries to find out the limitations of the rammed earth structures to be multistory and grope for solutions in the attached wall construction method. The procedures of this research is to figure out the limitations of rammed earth structures through theoretical consideration on those structures and analyze the actual cases of them, and to assure the possibilities on the development of the rammed earth method that can make the structures multistory earthen structures in the rammed earth method and induce immediate issues for it.

Seismic Analysis of Spent Fuel Storage Structures for PHWR Plant (중수로형 핵연료 저장대의 내진해석 방법)

  • 신태명
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.338-344
    • /
    • 2003
  • The seismic analysis method of spent fuel storage structures for PHWR plant is introduced in comparison with the method for PWR plant. Investigating the structural characteristics of the storage structures, the former is vertically stacked fuel storage trays, while the latter is welded honeycomb type structure. However, as both structures are submerged and free standing, the analysis methods to anticipate the seismic response of both structures are complicated. For the better estimation of actual seismic response, how to model the dynamic properties and the structural behaviour is the key issue. In this paper, the overall procedures of the seismic modelling and stability check for seismic sliding and overturning of the two different storage structures are discussed in the viewpoint of analysis reliability

  • PDF

Earthquake Damage Monitoring for Underground Structures Based Damage Detection Techniques

  • Kim, Jin Ho;Kim, Na Eun
    • International Journal of Railway
    • /
    • v.7 no.4
    • /
    • pp.94-99
    • /
    • 2014
  • Urban railway systems are located under populated areas and are mostly constructed for underground structures which demand high standards of structural safety. However, the damage progression of underground structures is hard to evaluate and damaged underground structures may not effectively stand against successive earthquakes. This study attempts to examine initial damage-stage and to access structural damage condition of the ground structures using Earthquake Damage Monitoring (EDM) system. For actual underground structure, vulnerable damaged member of Ulchiro-3ga station is chosen by finite element analysis using applied artificial earthquake load, and then damage pattern and history of damaged members is obtained from measured acceleration data introduced unsupervised learning recognition. The result showed damage index obtained by damage scenario establishment using acceleration response of selected vulnerable members is useful. Initial damage state is detected for selected vulnerable member according to established damage scenario. Stiffness degrading ratio is increasing whereas the value of reliability interval is decreasing.

A Study on the Retail Competitive Structure When a Large Discount Store Enters Small Cities (대형할인점의 중소도시 진입에 따른 소매점 유통경쟁구조 분석)

  • 박성용
    • Journal of Distribution Research
    • /
    • v.7 no.2
    • /
    • pp.21-44
    • /
    • 2003
  • The entry of large discount stores into small cities such as Choonchun or Wonju have had a profound impacts on the businesses of small-sized retailers. The impacts of the entry by large discount store will be much larger than those of the entry by department store or other small-scale retailers. Most of research studies on the competitive retail structure focused on the change of retailing in the advanced countries dynamically and investigated macro-trends in sales and market share. As a result, they tend to overlook the micro aspects of consumers" perception and actual behaviors. Furthermore, they tend to limit their research scopes to relatively competitive retailers not to overall competitive structures. In this study, we analyze the overall competitive structures by investigating the retailers" characteristics, perceptions of consumers on retailers and actual purchase of products across different types of retailers We could obtain competitive retail structure. Based on that, we discuss the strategies on the revitalization and enhancement of small-sized retailers" productivities.

  • PDF

A Model for Activation Energy of Moisture Diffusion in Wood (수분확산(水分擴散)의 활성화(活性化)에너지 모델)

  • Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.21-30
    • /
    • 1992
  • An activation energy equation for moisture diffusion in wood was developed with an assumption that activation energy is directly proportional to wood specific gravity. Theoretical activation energies obtained from the activation energy equation were revealed to be always lower than actual activation energies, which implies that activation energy isn't affected only by wood specific gravity. The other affecting factors are possibly anatomical structures of wood which determine a ratio of vapor diffusion to bound water diffusion in wood. For the convenience of estimating actual activation energy by using the activation energy equation, thirteen kinds of species were categorized into three groups according to their anatomical structures.

  • PDF

An Experimental Study on a Bond Stress in Concrete Filled Circular Steel Tubular Column Strengthened by the Stiffener (스티프너로 보강한 콘크리트 충전 원형 강관기둥의 부착응력에 관한 실험적 연구)

  • Park, Sung-Moo;Kim, Sung-Su;Kim, Won-Ho;Lee, Hyung-Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.2 s.4
    • /
    • pp.51-58
    • /
    • 2002
  • This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.

  • PDF