• Title/Summary/Keyword: active pressure

Search Result 959, Processing Time 0.022 seconds

FLOW DISTRIBUTION IN THE CORE OF HANARO AFTER SUPPRESSING THE JET FLOW IN THE GUIDE TUBE USED FOR LOADING FISSION MOLY TARGET (Fission Moly 표적을 장전하기 위한 안내관의 제트유동 억제 후 하나로 노심 유량분포)

  • Park Yong Chul;Lee Byung Chul;Kim Bong Soo;Kim Kyung Ryun
    • Journal of computational fluids engineering
    • /
    • v.10 no.4 s.31
    • /
    • pp.66-71
    • /
    • 2005
  • HANARO, a multi-purpose research reactor, 30 MWth open-tank-in-pool type, is planning to produce a fission moly-99 of radio isotopes, a mother nuclide of Tc-99m, a medical isotope and a target handling tool is under development for loading and unloading it in a circular flow tube (OR-5) of HANARO. A guide tube is extended from the reactor core to the top of the reactor chimney for easily loading the target under a normal operation of the reactor. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube. The jet flow was suppressed in the guide tube after reducing the inner diameter of a flow restriction orifice installed in the OR-5 flow tube for adding the pressure difference in the flow tube. This paper describes an analytical analysis to calculate the flow distribution in the core of HANARO after suppressing the jet flow of the guide tube. As results, it was confirmed through the analysis results that the flow distribution in the core of HANARO were not adversely affected.

General Pharmacology of ADP

  • Ban, Ju-Yeon;Lee, Bo-Young;Hong, Eun-Kyung;Jung, Young-shin;Seong, Yeon-Hee
    • Biomolecules & Therapeutics
    • /
    • v.11 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • General pharmacological properties of ADP, a new pharmaceutical composition, which contains a mixed water extract obtained from the mixture of Phellodendron cortex (Phellodendron amurense) and Anemarrhena rhizoma (Anemarrhena asphodeloides), as the active ingredients, were investigated in experimental animals administering orally and in vitro test system. ADP had no influences on general behavior, pentobarbital sleeping time, spontaneous motor activity, motor coordination of mice, normal body temperature, chemoshock produced by pentylenetetrazole and writhing syndromes induced by 0.8% acetic acid at the dose of 150 and 1500 mg/kg. Gastric secretion of rats and intestinal motility of mice were not also influenced by the administration of ADP at doses of 150 and 1500 mg/kg, with the exception of the significant decrease of free HCI concentration at a dose of 1500 mg/kg in rats. ADP (150 and 1500 mg/kg) did not alter mean arterial blood pressure and heart rate in conscious rats. ADP given to anesthetized rats showed no effect on respiratory rate at the same doses. In in vitro experiments, ADP at the concentration of 150 mg/L did not show direct effect and inhibitory or augmentative action on histamine- or acetylcholine-induced contractions in the isolated ileum of guinea-pig. Taken together, these results indicate that ADP does not induce any adverse effects in experimental animals.

An Experimental Study of Verification for PEMFC's 1-Dimensional Simulation (PEMFC 1차원 시뮬레이션 검증을 위한 실험적 연구)

  • Moon, Cheor-Eon;Ahn, Seong-Yool;Yang, Jang-Sik;Choi, Gyung-Min;Kim, Duck-Jool
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.191-195
    • /
    • 2007
  • In this study, we estimated the performance of PEMFC's unit cell as changing operating temperature in different inlet humidity condition at cathode side but anode dry, and tried to match experimental results with 1-dimensional simulation. We used $Nafion^{\circledR}112$ membrane and a self-manufactured PEMFC with active area of $25cm^{2}$ was used in this study. The range of operating temperature was $40{\sim}70^{\circ}C$ and oxygen through bubbled humidity chamber was supplied $0{\sim}80$% humidity condition as changing water temperature in humidity chamber. For figuring out governing equations, represent water contents in electrolyte membrane, the linear forward difference method was applied about time progress and quadratic central difference method was used about space progress. It was assumed that pressure terms were linearly changed due to thin electrolyte membrane. In low operating temperature condition, $40{\sim}60^{\circ}C$, increasing temperature rarely effected cell performance but we can see performance drop at $70^{\circ}C$. By modifying Henrry's constant and/or diffusion coefficient, the modified one-dimensional model was accomplished for calculation.

  • PDF

Control of Combustion Instabilities in a Gas Turbine Combustors Through Secondary Fuel Injection (가스터빈 연소기내 2차연료분사에 의한 연소 불안정성의 제어)

  • Jeon, C.H.;Santavicca, Domenic A.
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.1
    • /
    • pp.59-69
    • /
    • 1998
  • The results of study on the active control of naturally occurring combustion oscillations with a single dominant frequency in an atmospheric dump combustor are presented. Control was achieved by an oscillatory infection of secondary fuel at the dump plane. A high speed solenoid valve with a maximum frequency of 250Hz was used as the actuator and a sound level meter, located at the combustor exit, measured the pressure fluctuations which served as the feedback signal for the control loop. Instability characteristics were mapped over a range of mean mixing section velocities from 6.7 m/s-9.3 m/s and with three mixing conditions. Different fuel/air mixing conditions were investigated by introducing varying percentages of primary fuel at two locations, one at the entrance to the mixing section and one 6 mixing tube diameters upstream of the dump plane. Control studies were conducted at a mean velocity of 9.3 m/s, with an air temperature of $415^{\circ}C$, and from flame blowout to the stoichiometric condition.

  • PDF

A study on gas vent control of injection mold for the production of precision medical device parts (정밀 의료기기 부품 생산을 위한 사출금형의 가스벤트 제어에 관한 연구)

  • Lee, Jeong-Won;Son, Min-Kyu
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.34-41
    • /
    • 2020
  • Typical characteristics of medical device parts are that they can not be reused and there are many disposable products. Therefore, there is a need for an injection molding machine having excellent repeatability of molding conditions and a precision injection mold for mass production. Recently, the performance of an injection machine has made a remarkable evolution compared to the past. However, defects such as short-shot, flash, weld line, gas burning, warpage, and deformation, which are typical defects, still do not disappear at all. This is due to the lack of gas ventilation from the product cavities, even if the gas is smoothly vented from the sprue and runner of the mold. For this reason, the internal pressure of the cavity rises and is directly connected to the quality defects. In this study, an active gas vent system was designed to prevent defects due to trapped gas in the cavity. Since it can be easily adjustable in response to the molding conditions and the mold temperature changes, it is expected to improve productivity due to the reduction of the defective ratio.

Combustion Instability and Active Control in a Dump Combustor (덤프 연소기에서의 연소불안정과 능동제어에 대한 연구)

  • Ahn Kyu-Bok;Yu Kenneth;Yoon Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.445-449
    • /
    • 2005
  • The mixed acoustic-convective mode combustion instability and the possibility of combustion control using a loudspeaker to these instabilities were studied. By changing inlet velocity, combustor length and equivalence ratio, the dynamic pressure signals and the flame structures were simultaneously taken. The results showed that as the combustor length increased and the inlet velocity decreased, the instability frequency decreased and the maximum power spectral densities of the dynamic pressures generally decreased. The instability frequency could be affected by an equivalence ratio over the operating conditions. From the data of close-loop control, as the loudspeaker may work out-of-phase with the natural instability, the optimum time-delay controller was confirmed to be able to reduce the vortex shedding from the mixed acoustic-convective mode combustion instability.

  • PDF

Experimental Investigation of the Effect of Partial Admission Ratio on the Performance of Supersonic Impulse Turbine (초음속 충동형 축류터빈의 부분분사비 효과에 대한 실험적 연구)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.4
    • /
    • pp.59-66
    • /
    • 2007
  • In this paper, experimental investigation results of the effect of partial admission ratio on the performance of axial turbine was presented. A supersonic impulse turbine of gas generator cycle liquid rocket engine turbopump was used for the test. for experimental purpose, a nozzle block, in which total 14 number of axi-symmetric convergent-divergent nozzles are arranged circumferentially, was designed and manufactured. Partial admission ratio was controlled by changing the number of active nozzles. High pressure air was used as working medium for the test. The experimental result revealed that the performance of the supersonic impulse turbine does not much affected by the partial admission ratio for supersonic impulse turbine.

Leaf Temperature Characteristics being Affected by Light Regimes (광조건에 따른 식물의 엽온 특성)

  • Park, Yong-Mok
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1599-1605
    • /
    • 2011
  • To evaluate heat environment surrounding plants diurnal change of leaf temperature in the broad-leaved deciduous and evergreen trees was measured with microclimatic environmental factors including global solar radiation, and upward and downward long wave radiation. Maximum daily solar radiation was 961.2 and 976.3 w/$m^2$ in August 9 and 23, respectively. Upward long wave radiation was slightly higher than downward long wave radiation, showing 404.2 w/$m^2$ in August 9 and 394.5 w/$m^2$ in August 23. In addition, daily maximum vapor pressure deficit was 5.42 and 6.84 kPa in August 9 and 23, respectively, indicating high evaporative demand. Quercus glauca and Acer mono was differently responded to changing light regimes. On August 9, leaf temperature at the top-positioned leaves of Acer plants was higher than air temperature as well as those of Quercus plants in the morning. This indicates that stomata in Acer plants were closed by heat stress or water stress in the morning, while Quercus plant maintained active transpiration by opening stomata. These results indicated that improved light regimes such as gap opening in the closed forest may not always affect positively in the physiology of understory plants.

Development and Application of an Early Exercise Program for Open Heart Surgery Patients (개심술 환자를 위한 조기 운동프로그램의 개발 및 적용에 관한 연구)

  • Ha, Yi-Kyung;Jung, Yoen-Yi
    • Journal of Korean Critical Care Nursing
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • Purpose: This study was to develop and evaluate stability and effects of an early exercise program for patients with open heart surgery. Methods: The subjects of this study were 30 patients who had either a coronary bypass surgery or a valvular heart surgery at a tertiary hospital in Seoul. The data was collected by observation and measurement from October 1, 2004 to November 15, 2004. Results: The early exercise program developed for this study consisted of range of motion exercise and walking. Intensity of walking was 1~3 METs and increased progressively to daily target distance. During exercise, the subjects were monitored heart rate, blood pressure and RPE (Rating of Perceived Exertion). The mean FIM (Functional Independent Measurements) score of subjects was significantly improved after the early exercise program. However, several complaints such as dizziness or pain were also reported. Most complaints were associated with chest tube and RPE. Conclusion: The early exercise program can help to recover patients' physical activities after surgery, and can be applied to most patients. Patients' RPE, dizziness and pain was possible limitations, therefore, active pain control and prevention of accidents for patients would be needed.

  • PDF

Numerical study on the interaction between unsteady compression and unsteady expansion wave (비정상 압축파와 비정상 팽창파의 간섭에 관한 수치해석적 연구)

  • Kim, Hui-Dong;Setoguchi, Toshiaki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1413-1421
    • /
    • 1997
  • A new control method to alleviate the impulsive noise at the exit of high-speed railway tunnel was applied to the compression wave at the entrance of the tunnel. This method uses the interaction phenomenon of unsteady expansion wave and unsteady compression wave. Unsteady expansion wave was assumed to be made instantaneously by the simple theory of shock tube. Total Variation Diminishing method was employed to solve the axisymmetric unsteady compressible flow field with a specified compression wave. Numerical results show that the maximum pressure gradient of the propagating compression wave decreases with increase of the wave length of the unsteady expansion wave. It is found that the impulsive noise reduction can be obtained when the unsteady expansion wave with a large wave length is emitted just before the train enters the tunnel. The present results give the possibility to reduce the impulsive noise at the exit of tunnel.