• 제목/요약/키워드: active filter

검색결과 1,114건 처리시간 0.038초

멀티미디어용 고주파 Active Filter개발에 관한 연구 (Development of High Frequency Active Filter for Multimedia)

  • 윤종남
    • 마이크로전자및패키징학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2002
  • 본 연구에서는 이동통신 시스템의 키부품으로 필수적인 멀티미디어용 고주파 Active Filter 및 초소형 설계기술(SMD타입)을 개발하였으며, 멀티미디어 고주파 능동필터의 카오프 주파수는 2.5 mHz, 이득은100 kHz에서 0.5d B, 통과대역 리플은 100 kHz에서 2 MHz까지 최고1.2dB, GDT는 100 kHz에서 2.0 MHz까지 최고 60 nsec이며, 감쇄는 3.7 MHz에서 최소 40dB임.

  • PDF

Series Hybrid Active Filter

  • 김원호;김종수;강유리;임근회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 1995
  • Hybrid active filters utilize passive filters to reduce the voltage rating and hence the VA rating of the active filter converter. A novel hybrid active filter topoloty to minimize utility current harmonics at high power levels is presented in this paper. The proposed topology combines both passive and active filters to obtain the lowest converter VA rating as compared to the converter rating in the active filter and the series-active hybrid filter configurations. This is demonstrated with experimental results from a laboratory model. Simulation results showing the effect of passive filter impedance are presented.

  • PDF

새로운 능동EMI필터의 결합회로에 관한 연구 (A Study on the Combining Circuit of New Active EMI Filter)

  • 최민환;신동석;이동호;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.78-89
    • /
    • 2015
  • Conventional EMI filters have tried to use an active EMI filter as a series by the series connection of two EMI filters for CM and DM noise. However, the proposed filter is formed into one circuit by using the active EMI filter which is able to filter CM and DM noise components together. As a result, the active EMI filter showed the outstanding quality in mass and volume under 50% and electric characteristics have been compared to the passive EMI filter in approximately 150kHz~10MHz. Furthermore, the proposed circuit has simple circuit components by comparing with the series EMI filters, and electrical characteristics are similar. The noise have been attenuated to maximum 20dBuV.

전력 능동 필터의 설계 및 시뮬레이션 (Design and Simulation of Active Power Filter)

  • 정동열;박종연;방선배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2629-2632
    • /
    • 2003
  • This paper presents the harmonics rejection technique and the simulation of a active power filter using power operational amplifier. The proposed active power filter consists of CT(current transformer), harmonics detector and harmonics amplifier. The harmonics detector is a high pass filter using a GIC(Generalized Impedance Converter). The harmonics amplifier consists of a power operational amplifier and passive filters. The simulation has been implemented by OR-CAD program. It is examined whether the proposed active power filter can be realized or not through simple experiments.

  • PDF

외란관측기를 사용한 복합형능동전력필터의 Deadbeat 제어에 관한 연구 (Deadbeat control of Hybrid Active Power filter using Distrubance-observer)

  • 조광승
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.123-126
    • /
    • 2000
  • When LC filter is connected parallel to the Active Power Filter a problem of the resonance between the Active Power Filter(AF) and LC filte often arises. in this paper Deadbeat control of Hybrid Active Power Filter using Disturbance-observer is introduced to solve this problem. By the estimation of the harmonics disturbance using proposed disturbance observer the compensation characteristics of the AF is improved and the resonant current is suppressed. The validity of proposed disturbance observer is verified from simulation results using PSIM

  • PDF

3상 3선식 시스템의 고조파 저감을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire System)

  • 한윤석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.735-738
    • /
    • 2000
  • In this paper we propose a series active power filter and a simple calculation method acquiring the reference voltage. A series active power filter is suitable to suppress harmonics produced by voltage type harmonic source such as a diode rectifier with filter capacitor on the DC side The proposed series active power filter system is applied to 3-phase 3-wire power system including the voltage type harmonic source. Experimental result obtained from a laboratory model are shown to verify the viability and effectiveness of the proposed system.

  • PDF

역률 개선 컨버터용 고차 능동 필터의 설계 및 분석 (Design and Analysis of High-order Active Input Filter for Power Factor Correction(PFC) Converter)

  • 이동영;조보형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 1996
  • In this paper, active input filter for power factor correction(PFC) circuit employing ripple arrent and voltage cancellation is proposed to reduce filter's size and cost, and to make filter design easy. Switching ripple current and voltage can be sensed through the secondary windings of filter inductor. Single stage passive filter can achieve high order filter characteristics by using active ripple current and voltage cancellation technique. Conventional high order passive filter and its problems are suggested. Analysis of active filter and design procedure are detailed. Simulation result is presented to verify high order filter characteristics of proposed scheme.

  • PDF

능, 수동센서를 이용한 수중환경에서의 표적추적필터 구조 연구 (A Study on Target Tracking Filter Architecture in Underwater Environment using Active and Passive Sensors)

  • 임영택;서태일
    • 한국군사과학기술학회지
    • /
    • 제18권5호
    • /
    • pp.517-524
    • /
    • 2015
  • In this paper, we propose a new target tracking filter architecture using active and passive sensors in underwater environment. A passive sensor for target tracking needs a bearing measurement of target. And target tracking filter for using passive sensor has the observability problem. On the other hand, an active sensor does not have the problem associated with system observability problem because an active sensor uses bearing and range measurement. In this paper, the tracking filter algorithm that could be used in the active and passive sensor system is proposed to analyze maneuvering target and to improve target tracking performance. The proposed tracking filter algorithm is tested by a series of computer simulation runs and the results are analyzed and compared with existing algorithm.

Switched Capacitor를 사용한 능동 여파기 설계에 관한 연구 (A Study on Design of Active Filters Using Switched Capacitors)

  • 이문수;김상호
    • 한국통신학회논문지
    • /
    • 제4권1호
    • /
    • pp.25-31
    • /
    • 1979
  • All the resitors in the active RC filter networks can be relplaced by the switched capacitors. Therefore, An SC filter circuit can be fully integrated using MOS technology. A switched capacitor is much better than a resistor in temperature and linearity characteristics, and the former can be fabricated on the much smaller area then the latter. In this paper, It is given the generalized disign method of the active SC filter from the active RC filter using Bilinear Z-transformation. By SC filtering Techniques using Bilinear Z-transform, It enalbes us to realize the FDNR and Gyrator filters, which could not be realized in the exsisting designs, and it permits the processing of signals at much higher frequenies that many previous designs do. Experiments show that the response of the SC active filter is similiar to that of its prototype active RC filter.

  • PDF

무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터 (A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power)

  • 이우철;현동석;이택기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF