• Title/Summary/Keyword: active domain

Search Result 561, Processing Time 0.023 seconds

Impact Damage Detection in a Composite Stiffened Panel Using Built-in Piezoelectric Active Sensor Arrays (배열 압전 능동 센서를 이용한 복합재 보강판의 충격 손상 탐지)

  • Park, Chan-Yik;Cho, Chang-Min
    • Composites Research
    • /
    • v.20 no.6
    • /
    • pp.21-27
    • /
    • 2007
  • Low-velocity impact damage in a composite stiffened panel was detected using built-in piezoelectric active sensor arrays. Using these piezoelectric active sensors, various diagnostic signals were generated to propagate Lamb waves through the structure and the responses were picked up to detect changes in the structure's vibration signature due to the damage. Three algorithms - ADI(Active Damage Interrogation), TD RMS (Time Domain Root Mean Square) and STFT (Short Time Fourier Transform) - were examined to express the features of the signal changes as one damage index. From damage detecting tests, two impact induced delaminations were detected and the location was estimated with the algorithms and diagnostic signals.

Active Control System of a Vehicle Suspension for improving Ride Quality (승차감향상을 위한 자동차현가장치의 능동제어시스템)

  • Park, Ho;Jeon, Euy-Sik;Roh, Byung-Ok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.102-109
    • /
    • 1998
  • As the fundamental study of an active suspension system, computer simulation is performed using a quarter model. Design data for the development of active suspension system are presented through performance estimation of active control laws in the time and frequency domain. The verification of compromise between ride quality and handling characteristics is carried out.

  • PDF

Frequency Characteristics of the Synchronous-Frame Based D-Q Methods for Active Power Filters

  • Wang, Xiaoyu;Liu, Jinjun;Hu, Jinku;Meng, Yuji;Yuan, Chang
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.91-100
    • /
    • 2008
  • The d-q harmonic detecting algorithms are dominant methods to generate current references for active power filters (APF). They are often implemented in the synchronous frame and time domain. This paper researches the frequency characteristics of d-q synchronous transformations, which are closely related to the analysis and design issues of control system. Intuitively, the synchronous transformation is explained with amplitude modulation (AM) in this paper. Then, the synchronous filter is proven to be a time-invariant and linear system, and its transfer function matrix is derived in the stationary frames. These frequency-domain models imply that the synchronous transformation has an equivalent effect of frequency transformation. It is because of this feature, the d-q method achieves band-pass characteristics with the low pass filters in the synchronous frame at run time. To simplify these analytical models, an instantaneous positive-negative sequence frame is proposed as expansion of traditional symmetrical components theory. Furthermore, the synchronous filter is compared with the traditional bind-pass filters based on these frequency-domain analytical models. The d-q harmonic detection methods are also improved to eliminate the inherent coupling effect of synchronous transformation. Typical examples are given to verify previous analysis and comparison. Simulation and experimental results are also provided for verification.

Analysis of Time Domain Active Sensing Data from CX-100 Wind Turbine Blade Fatigue Tests for Damage Assessment

  • Choi, Mijin;Jung, Hwee Kwon;Taylor, Stuart G.;Farinholt, Kevin M.;Lee, Jung-Ryul;Park, Gyuhae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • This paper presents the results obtained using time-series-based methods for structural damage assessment. The methods are applied to a wind turbine blade structure subjected to fatigue loads. A 9 m CX-100 (carbon experimental 100 kW) blade is harmonically excited at its first natural frequency to introduce a failure mode. Consequently, a through-thickness fatigue crack is visually identified at 8.5 million cycles. The time domain data from the piezoelectric active-sensing techniques are measured during the fatigue loadings and used to detect incipient damage. The damage-sensitive features, such as the first four moments and a normality indicator, are extracted from the time domain data. Time series autoregressive models with exogenous inputs are also implemented. These features could efficiently detect a fatigue crack and are less sensitive to operational variations than the other methods.

A Quantitative Analysis of Activation Pattern of Active Elbow Muscles (주관절 근육의 활성화 유형에 대한 정량적 분석)

  • Lee, Du-Hyoung;Lee, Young-Seock;Lee, Jin;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.413-420
    • /
    • 1997
  • In this paper, we analyzed the contraction patterns of active elbow muscles during isometric, concentric and eccentric contraction. The analysis parameters consist of frequency domain parameters (mean frequency, median frequency, peak frequency, peak power, skewness, kurtosis) and time domain paraseters (zero crossing, positive maxima, integrated EMG). The results of this study were as follows; The BR/BB of isometric contraction appeared to be Venter as the elbow joint was more extended. The BR /BB during concentric and eccentric contraction tended to increase with more extension of the elbow joint angle, but there was no significant difference between concentric and eccentric contraction. Further, the EMG power spectrum due to the type of contraction were different betwen eccentric and concentric contraction. According to the results, it was found that the activation pattern in elbow flexor muscles was different during three different muscle contraction pattern. Therefore, elbow flexor muscles should not be considered a single functioning unit. Especially, at the time domain analysis, IEMG is a dominant parameter for analysis of activation patterns, and the skewness kurtosis can be useful parameters in functional recognition for prosthesis control purpose.

  • PDF

A Multiband Shunt Hybrid Active Filter with Sensorless Control

  • Kumar S, Surendra;Sensarma, Partha Sarathi
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper proposes a Multiband Shunt Hybrid Active Filter (SHAF) with sensorless control. A plant is modeled in the discrete- time domain and a controller is designed using the Pole shifting law in the polynomial domain. This control approach is very useful for filtering the load harmonics with reduced sensor counts where a low cost solution like SHAF is required. Multiple Synchronous Reference Frames (MSRF) and low pass filters are used to measure the $5^{th}$ and $7^{th}$ harmonic components separately from the load and filter currents. Individual current controllers are designed for the $5^{th}$ and $7^{th}$ harmonic currents. Control is realized in the stationary, three-phase (abc) reference frame. Performance of the controller is validated through simulation, using realistic plant and controller models, as well as experimentally on a full-scale distribution system.

Implementation of a Line-voltage Sensorless Active Power Filter (입력전원 센서리스 능동형 전력필터의 구현)

  • Jeong, Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.189-191
    • /
    • 2005
  • This paper proposes an implementation of a line- voltage sensorless three-phase active power filter. The line synchronization for an active power filter does not require any additional hardware. It can be properly operated under various line-voltage variation. Current compensation is done in the time domain allowing fast time response. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. It is shown via experimental results that the proposed controller gives good performance for the line-voltage sensorless active power filter.

  • PDF

Power Tracking Visualization Program Development (Power Tracking 시각화 프로그램 개발)

  • Oh, Sea-Seung;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.266-268
    • /
    • 2006
  • Power tracking은 발전기가 생산하는 전력의 흐름을 추적함으로써 특정 발전기가 특정 부하에 공급하는 전력의 양, 측정 송전선 점유율, 계통손실에 기여량 등을 결정할 수 있게 해준다. 본 논문에서는 loop화되어 있는 실계통을 여러 domain으로 나누고 하나의 domain 또는 중첩된 domain 간의 교류송전선의 대체 안으로 FACTS나 HVDC과 같은 active 소자의 설치위치를 선정하기 위해 power tracking을 이용하였으며 이를 효과적으로 시각화 하기위한 프로그램을 개발하였다.

  • PDF

Synthesis of Active Filers Using Linear Transformation (선형변환기법을 이용한 능동여파기의 구성에 관한 연구)

  • 이태원;조용현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.2
    • /
    • pp.41-51
    • /
    • 1983
  • An efficient method for the desist of active filters from doubly terminated lossless ladder type passive filters is presented. This technique is based on the linear transformation of network variables from the voltage-current domain to a new domain for the active realization of the passive networks. The method developed herein applies the linear transformation to a ladder building block which contains both a shunt and a series reactive arm, resulting in the minimization of the number of operational amplifiers required for the active realization. The validity and efficiency of this method are verified by the design of the 8th-order Chebyshev low-pass filter followed by the measurement of its frequency characteristics which fairly agree with the theoretic ones.

  • PDF

Intelligent hybrid controlled structures with soil-structure interaction

  • Zhang, X.Z.;Cheng, F.Y.;Lou, M.L.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.573-591
    • /
    • 2004
  • A hybrid control system is presented for seismic-resistant building structures with and without soil-structure interaction (SSI). The hybrid control is a damper-actuator-bracing control system composed of passive and active controllers. An intelligent algorithm is developed for the hybrid system, in which the passive damper is designed for minor and moderate earthquakes and the active control is designed to activate when the structural response is greater than a given threshold quantity. Thus, the external energy for active controller can be optimally utilized. In the control of a multistory building, the controller placement is determined by evaluating the optimal location index (OLI) calculated from six earthquake sources. In the study, the soil-structure interaction is considered both in frequency domain and time domain analyses. It is found that the interaction can significantly affect the control effectiveness. In the hybrid control algorithm with intelligent strategy, the working stages of passive and active controllers can be different for a building with and without considering SSI. Thus SSI is essential to be included in predicting the response history of a controlled structure.