• Title/Summary/Keyword: acquisition time

Search Result 2,020, Processing Time 0.022 seconds

Performance of PN Code Acquisition with Nonlinear Power Amplifier based on DMF for CDMA Mobile Communications

  • Park, Seung-Keun;Chung, Hee-Chang;Park, Se-Jun;Kim, Seong-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1E
    • /
    • pp.22-26
    • /
    • 2000
  • In this paper, the DS/CDMA PN code acquisition system with nonlinear transmitter power amplifier based on digital matched filter (DMF) which has the rapid acquisition time is presented and the performance is evaluated in terms of mean acquisition time, detection probability, and signal to interference under multiuser environment. The performance is presented with respect to the output backoff of the nonlinear amplifier and the correlation window.

  • PDF

An Efficient Code Acquisition Scheme for DSSS-based Real-Time Locating Systems

  • Lim, Jong-Tae;Park, Hyung-Rae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1A
    • /
    • pp.41-48
    • /
    • 2011
  • This paper proposes an efficient code acquisition scheme for direct-sequence spread spectrum (DSSS) based real-time locating systems (RTLS). The proposed scheme employs multiple bit integration to significantly decrease false alarms when no packet signal is transmitted and increase the detection probability when the RTLS tags are excited. The performance of the proposed code acquisition scheme is analyzed and numerically evaluated, and compared with those of single-dwell and traditional double-dwell code acquisition schemes. The simulation results show that the proposed multiple-bit integration scheme outperforms single-dwell and double-dwell schemes.

Development of real-time wireless data measurement technique on Centrifugal experiment (원심모형 실험기의 실시간 무선데이터 측정시스템 구축)

  • Lee, Jong-Pil;Kim, You-Seok;Park, Jin-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1289-1293
    • /
    • 2010
  • A slipring or FORJ are usually adopted in order for power supply of Geo-centrifuge and input/output data acquisition. Since using slipring causes quite a lot electrical noise, an optical communication using FORJ becomes more general for data acquisition. Such data acquisition devices, however, require frequent maintenance and replacement due to deterioration by long term usage. DICT has set up a real-time wireless date acquisition system using wireless communication technology instead of FORJ. The system enables a remote measurement at any inertial acceleration field up to 100g level and provides as same performance as FORJ. The priority of this system is to use a normal modem substituting a special FORJ.

  • PDF

Enhancement of acquisition performance using interference suppression filter in a microcellular environment (마이크로셀 환경에서 간섭억압여파기를 이용한 포착성능의 향상)

  • 김진영;이재홍
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.8
    • /
    • pp.10-19
    • /
    • 1997
  • In this paper, perfodrmance of matched-filter (MF) acquisition scheme is analyzed for a direct-sequence/code-division-multiple-access (DS/CDMA) system in a microcellular environment. Mean acquistion time is used as a performance measure. It is demonstrated that acquisition performance is enhanced using interference suppression filter in a Rician fading channel. To apply for multiuser environments, multiple access interference is considered in the performance analysis. From the numerical results, it is shown that mean acquistion time decreases with the increasing SNR/chip, and acquisition performance is improved as the number of taps of interference suppression filter. It is also shown that mean acquisition time increases with the number of users in the system, and acquistion performance is degraded as the icrease of narrowband interference bandwidth. The analysis in this paper can be applied to a DS/CDMA overlay environment.

  • PDF

O-CDMA Code Acquisition Algorithm Based on Magnitude and Sign of Correlation Values (상관값의 크기와 부호에 기반한 O-CDMA 부호 획득 알고리즘)

  • Chong, Da-Hae;Yoon, Tae-Ung;Lee, Young-Po;Lee, Young-Yoon;Song, Chong-Han;Park, So-Ryoung;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6C
    • /
    • pp.649-655
    • /
    • 2009
  • Mean acquisition time (MAT) is the most important performance measure for code acquisition systems, where a shorter MAT implies a better code acquisition performance. Keshavarzian and Salehi proposed the multiple-shift (MS) algorithm for code acquisition in optical code division multiple access (O-CDMA) systems. Performing two steps acquisition, the MS algorithm has a shorter MAT than that of the conventional serial-search (SS) algorithm. In this paper, we propose a rapid code acquisition algorithm for O-CDMA systems. By using an efficient combination of local signals, correlation value, and the sign of correlation value, the proposed algorithm can provide a shorter MAT compared with that of the MS algorithm. The simulation results show that the proposed algorithm presents a shorter MAT than that of the MS algorithm.

A Four State Rotational Frequency Detector for Fast Frequency Acquisition

  • Yeo, Hyeop-Goo
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.3
    • /
    • pp.305-309
    • /
    • 2011
  • This paper proposes a new rotational frequency detector (RFD) for phase-locked loop (PLL) or clock and data recovery (CDR) applications for fast frequency acquisition. The proposed RFD uses the four states finite state machine (FSM) model to accelerate the frequency acquisition time. It is modeled and simulated with MATLAB Simulink. The functionalities of the proposed RFD are examined and the results are compared to those of a conventional RFD. The proposed RFD's frequency acquisition time is four times faster than that of a conventional one. The proposed RFD incorporated with a phase detector (PD) in PLL or CDR is expected to improve the frequency and phase acquisition performance later greatly.

Systems Engineering Application of Imaginary WIG(Wing-In-Ground Effect) Ship Acquisition Project (가상 함정획득사업의 Systems Engineering 적용 (INCOSE SE Handbook ver. 3.1 중심으로))

  • Lee, Su Oek;Shin, Seung Chun;Choi, Nag Jun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2009
  • The purpose of Defense Acquisition Project is that the superior weapons validated needs and performance are supplied to military user with limited financial resources and time. The Warship Acquisition Project is not only like this, But also has special characteristics of long project period and first-constructed ship's operation employment. So, The Warship Acquisition Project need systematic and efficient procedure & management. And this paper researches System engineering application of imaginary WIG(Wing-In-Ground Effect) ship acquisition project based Systems Engineering Handbook ver.3.1 published by INCOSE, the lead of field. The Imaginary WIG(Wing-In-Ground Effect) ship acquisition project applied the four processes(technical project, Enterprise & Agreement, Enabling Systems), the basis of INCOSE Engineering Handbook ver.3.1, and the each process output compared with DAPA(Defense Acquisition Program Administration)'s warship acquisition procedure.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

A Dynamic Camera Actuation System for Simultaneous in Situ Image Acquisition on a Lab-on-a-disk (랩-온-어-디스크를 위한 실시간 영상 조절 및 이미지 획득 시스템)

  • La, Moonwoo;Park, Sang Min;Park, Sung Jea;Kim, Dong Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1211-1216
    • /
    • 2013
  • In this study, a dynamic camera actuation system for simultaneous in situ image acquisition is developed to achieve real-time observation of transient liquid flow on a lab-on-a-disk. A disk-type electric circuit, namely circuit-on-a-disk, co-rotated with the lab-on-a-disk improves the dynamic image acquisition ability in terms of a frame rate. The circuit-on-a-disk is comprised of a camera connected with a motor, a microprocessor and a wireless communication module. The camera connected with the motor enables to realize dynamic tracking of a transient flow and real-time image acquisition. The obtained images can be simultaneously transferred by a video/audio transmitter unit to a personal computer. Also, the microprocessor receives signals from the personal computer, and then controls the focusing position of the camera. We are expecting that heaters, sensors, and light sources also can be integrated on the circuit-on-a-disk, and they will enable various functional actuations as well as precise image acquisition.

Hybrid PN Code Search with Soft-decision Technique (연판정 하이브리드 PN 코드 동기 획득 기법)

  • Lee Seong-Joo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7A
    • /
    • pp.682-688
    • /
    • 2006
  • In this paper, a soft-decision method for initial PN code acquisition in pilot-channel aided Direct Sequence Code Division Multiple Access (DS-CDMA) systems is proposed in order to improve the acquisition performance. We apply this technique to the conventional hybrid search algorithm and analyze it in terms of mean code acquisition time. For the analysis, we present mathematical model of proposed algorithm and also perform the simulation under IMT-2000 channel models. Numerical results show that our proposed scheme outperforms the conventional one by 0.2 - 0.4 sec with respect to the mean code acquisition time because the soft decision technique can mitigate the possible decline in search performance caused by the use of a hard-decision technique.