• Title/Summary/Keyword: accuracy-study

Search Result 16,172, Processing Time 0.041 seconds

A Study on Direction Finding Accuracy Analysis for Airborne ESM (항공용 전자전장비의 방향탐지 정확도 분석기법)

  • Lee, Young-Joong;Kim, In-Seon;Park, Joo-Rae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.63-73
    • /
    • 2008
  • The helicopter position, heading data and the direction finding data of ESM are essentially required to compensate the parallax and analyze the direction finding accuracy of heliborne ESM in flight test phase. In the case of the long test range compared with small platform like as LYNX helicopter and Jisim Island test site, the parallax compensation for direction finding accuracy calculation and GPS position error can be neglected. In this paper, the direction finding accuracy on the basis of helicopter propeller was calculated by coordinate changing between helicopter and transmitting antenna from WGS84 coordinate to navigation coordinate using helicopter position and direction finding data.

Oil Spill Detection from RADARSAT-2 SAR Image Using Non-Local Means Filter

  • Kim, Daeseong;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.1
    • /
    • pp.61-67
    • /
    • 2017
  • The detection of oil spills using radar image has been studied extensively. However, most of the proposed techniques have been focused on improving detection accuracy through the advancement of algorithms. In this study, research has been conducted to improve the accuracy of oil spill detection by improving the quality of radar images, which are used as input data to detect oil spills. Thresholding algorithms were used to measure the image improvement both before and after processing. The overall accuracy increased by approximately 16%, the producer accuracy increased by 40%, and the user accuracy increased by 1.5%. The kappa coefficient also increased significantly, from 0.48 to 0.92.

A Study on the Optimal Structural Design and Computer Simulation of Delta Stage for ultra Precision Positioning (초정밀위치결정을 위한 델타스테이지의 최적 설계 및 컴퓨터 시뮬레이션에 관한 연구)

  • 김재열;김영석;송찬일;곽이구;한재호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.221-225
    • /
    • 2001
  • Recently, high accuracy and high precision are required in various industrial fields that are composed of semiconductor manufacturing apparatus and ultra precision positioning apparatus and information system and so on. The positioning technology is a very important one among them. This technology has been rapidly developed, its field needs for positioning accuracy to high as submicron. It is expected that accuracy with 10 nm in precision working and accuracy with 1 nm in ultra precision working are reached at the beginning of 2000s. Recently, to accomplish this positioning technology, many researches are concerned about it and make efforts it. This paper contain design technology of ultra precision 2-axis(X-Y Delta) stage for materialize to positioning accuracy with submicron, where, Delta stage is design as optimum against load and disturbance. And computer simulation is performed for stability and dynamic characteristic of Delta stage.

  • PDF

A Study on Practical PMM Test Technique for Ship Maneuverability Using System Identification Method (선박의 조종성능 추정에 있어서 시스템식별법을 이용한 PMM 시험 기법에 대한 연구)

  • 이태일;권순홍
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.6
    • /
    • pp.25-31
    • /
    • 2002
  • A system identification method is introduced to increase the prediction accuracy of a ship's maneuverability in PMM test, analysis. To improve the accuracy of linear hydrodynamic coefficients, the analysis techniques of pure sway and yaw tests are developed, and confirmed. In the analysis of sway tests, accuracy to linear hydrodynamic coefficients depends on the frequency of sway motion. To obtain nonlinear hydrodynamic coefficients for large drift angles, a combined yaw test is introduced. Using this system identification method, runs of PMM test can be reduced while retaining sufficient accuracy, compared to the Fourier integration method. Through the comparisons with sea trial results and the Fourier integration method, the accuracy and efficiency of the newly proposed system identification method, based on least square method, has been validated.

The Effect of Mental Practice on Motor Task Performance Accuracy (정신훈련이 운동과제 수행시 정확도에 미치는 효과)

  • Lee, Kyung-Sook;Jung, You-Jin;Cheon, Myung-Soon;Current, Marion E.
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.40-45
    • /
    • 1995
  • The purpose of this study was to investigate the effectiveness of mental practice in increasing accuracy of performance during motor task. Forty healthy students aged 17 years were randomly assigned to two groups. The experimental group(n=20) performed mental practice; the control group(n=20) performed nothing. The task was dotting. No significant change was seen between pre and post test subtest results following mental practice sessions(p>0.05). The experimental group's accuracy improved a little but this was not valuable statistically(p>0.05). We could not prove that mental practice was effective in increasing accuracy of motor task performance.

  • PDF

A Study on the Laser Measurement Experiment for Performance Advancement of Tilting Index Table (틸팅 인덱스 테이블의 성능 향상을 위한 레이저 측정 실험에 관한 연구)

  • Kim, Kwang-Sun;Lee, Tae-Ho;Lee, Choon-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.26-30
    • /
    • 2011
  • Currently, many researches are carried out about tilting index table, which is one of the main component of 5-axis machine tool. The performance of the tilting index table is associated the rotational accuracy which is very important factor for high precision machining because it have an effect on machining error. In this paper, a tilting index table is developed, and the rotational accuracy of the tilting index table using a laser measurement equipment is measured. In addition, a correction value is obtained from the measured value through compensation, and the correction value is used to improve the accuracy of the table. Comparative analysis is carried out for the accuracy of the table before and after compensation. This paper can be used by a reference for performance and reliability advancement of tilting index table.

The effect on the position precision by load in M.C. (머시닝 센터에서 하중이 위치결정정밀도에 미치는 영향)

  • 이승수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.143-147
    • /
    • 1998
  • As the accuracy of manufactured goods needed high-accuracy processing has made the efficiency of NC and measurment technology develop, the innovation of machine tools has influence the development of the semi-conductor and optical technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics - Stylus instrument method, STM, SEM, Laser interferometer method - which are used for measuring the movement accuracy of machine tools. The movement error factors in movement accuracy are expressed as yaw, roll, and pitch etc. Machining center has 21 movement error factors including of 3 axies joint errors because that has 3 axies and has been measured as the standard of the unloaded condition until now inspite of getting static, dynamic, and servo-gain errors in the case of expending the error range. Therefore, this study tries to measure position accuracy according to loading on the X-Y table of the machining center.

  • PDF

Accuracy Analysis of Sounding Data Caused by Speed of Robot-ship (원격 로봇선에 의한 운항속도에 따른 수심측량의 정확도 분석)

  • Choi, Byoung-Gil;Park, Hong-Gi;Cho, Kwang-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.111-116
    • /
    • 2007
  • This study is aimed to analyze the accuracy of depth information of reservoir using the robot-ship equipped with GPS and echosounder. The accuracy of depth measurements by sounding data was analyzed according to change of robot-ship's speed in the water. The field experiment results showed that as robot-ship's speeds were slow, accuracy of sounding data were increased. Until Robot-ship's speed was up to 5 km/hr, the accuracy of sounding data were included reliable section of normal distribution.

  • PDF

A study on application of dimension accuracy compensation by CAD (CAD에 의한 치수정밀 보정값 적용에 관한 연구)

  • Lee, Si-heon;Won, Si-tae
    • Design & Manufacturing
    • /
    • v.2 no.1
    • /
    • pp.11-14
    • /
    • 2008
  • we can save a development cost and time as computer was used in tool and die design of car fields in die manufacture process. Dimension accuracy errors such as springback, springgo, overcrown and twist were reduced product accuracy and caused trouble to assembly each parts of car. In this paper, CADCEUS was used to modify and optimize results of deflection for a tail gate panel of car parts in order to reduce dimension accuracy errors by springback in sheet metal forming. As CADCEUS was used to apply for a tail gate panel, the time for quality to improve was reduced to 30%.

  • PDF

A study on the diagonal error compensation and squareness measurement of linear motor (리니어 모터의 직각도 측정과 대각선 오차 보정에 관한 연구)

  • Kim J.H.;Lee C.W.;Song J.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.287-288
    • /
    • 2006
  • This paper introduces an approach of method to compensate accuracy error of diagonal direction. The measurement of squareness error is an important parameter in performance test of two axis Linear Motor and this exerts influence on accuracy error of diagonal test. However, previous knowledge management approaches are limited in deviation measurement of optical axis or restrictive elements of diagonal measurements using laser interferometer. But this proposed method calculated diagonal accuracy error which was occurred by squareness error and compensated squareness error using orthogonal correction method of PMAC. From this result, diagonal accuracy error is significantly reduced. This experimental results show that geometric error of squareness error is easily corrected by dynamic coordinate correction.

  • PDF