• Title/Summary/Keyword: accuracy test

Search Result 4,855, Processing Time 0.035 seconds

3D Finite Element Analysis of Lateral Loaded Pile using Beam and Rigid Link (빔요소와 Rigid 링크를 이용한 수평하중에 대한 말뚝 거동 3차원 유한요소해석)

  • Park, Du-Hee;Park, Jong-Bae;Kim, Sang-Yeon;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.4 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • The BNWF (Beam on Nonlinear Winkler Foundation) model is one of the simplest idealizations for a pile embedded in soil as it ignores the continuity of the soil. This method is difficult to model the behavior of pile group foundation subjected to lateral loading. The limitation can be overcome with the utilization of the finite element method (FEM) or finite different method (FDM) to represent a pile element embedded in a soil medium. Both the ground and piles are modeled with soild elements. The solid elements, which do not have rotational degree of freedom, is not appropriate for modeling piles. It can be overcome by substantially increasing the number of elements, which can be prohibitive for 3D modeling. This paper used the beam element and rigid link incorporated in the OpenSees to model the pile. The accuracy of the model is validated through comparison with lateral load test and BNWF analysis. It is shown that the method can capture the measured behavior accurately. It is therefore recommended to be used in group pile analyses.

Comparison of Two Commercial Antibody Enzyme-Linked Immunosorbent Assays for Detection of Porcine Reproductive Respiratory Syndrome Virus Infection (돼지생식기호흡기증후군(PRRS) 바이러스 감염 항체 검출 ELISA 상용 키트의 정확도 비교)

  • Pak, Son-Il;Lee, Seung-Hwan;Park, Kyung-Ae
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.102-106
    • /
    • 2016
  • More than 20 years after the first report of porcine reproductive and respiratory syndrome virus (PRRSV) in Korea, the disease is still having major impact on domestic pig health and relevant industries. Although ELISA tests are commonly used by veterinarians to guide herd management, data on diagnostic performance of the test in field settings are very limited. The objective of this study was to evaluate two commercially available PRRSV ELISA (IDEXX PRRS X3 ELISA and Bionote PRRSV ELISA 4.0) to detect antibodies against PRRSV on serum samples. To this end, a total of 1,108 sera were recruited from 35 swine farms located in Gyeonggi province and tested at the Gyeonggi Province Veterinary Service Center. All tests were performed according to the manufacturer's instructions, by laboratory technicians who routinely perform PRRS testing on blood samples. Samples were collected from two sources of swine populations with different PRRS prevalence; 60 samples (5.4%) were originated from breeding farms and the remaining 1,048 samples (94.6%) were from farrow-to-finish farms. We applied Bayesian latent class model (LCM) for two-tests in the two-population when the accuracy of the gold standard is not available. The model estimated that Bionote ELISA was a bit more specific but slightly less sensitive. The estimated sensitivity and specificity of the IDEXX ELISA were 99.8% (95% CI 98.1-100%) and 86.4% (95% CI 81.4-96.5%), respectively. Sensitivity, specificity, positive predictive value and negative predictive value for Bionote kit were 98.7% (95% CI 92.8-100%), 89.8% (95% CI 86.2-93.1%), 93.8% (95% CI 91.5-96.0%), and 97.8% (95% CI 87.1-100%), respectively. Based on the Bayesian 95% credible intervals, the sensitivity and specificity of the two ELISAs were not significantly different each other when assuming that two kits were imperfect, indicating that two kits performed equally well in terms of sensitivity and specificity in our filed setting.

Clinical Features of Electrogastrogram in Dyspeptic Patients with Stomach Qi Deficiency (위기허증으로 진단된 소화불량 환자의 임상적 특징; 위전도 검사를 중심으로)

  • Jeong, Hae-in;Kim, Dong-yoon;Baek, So-young;Lee, Ha-nul;Lee, Hyun-jin;Cho, Yun-jae;Ha, Na-yeon;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.467-477
    • /
    • 2020
  • Objectives: This study investigated the cutaneous electrogastrogram (EGG) and other clinical characteristics of dyspeptic patients who have been diagnosed with Stomach Qi Deficiency (SQD) using the Scale for Stomach Qi Deficiency (SSQD). Methods: This study reviewed the clinical records of 38 patients with dyspepsia who were evaluated with SSQD and EGG at the Department of Digestive Diseases of Kyung Hee University Korean Medicine Hospital in Seoul, Korea from November 1, 2019 to February 29, 2020. We evaluated the EGG and other clinical characteristics of the SQD patients to determine if there was an association between the SSQD scores and the EGG. Results: In terms of the EGG, the SQD patients showed no significant increase in the percentage of normal slow wave after a meal and a slightly decreased power ratio at Channel 1 and Channel 2. We also found an association between the SSQD scores and the EGG parameters at Channel 1 and Channel 3. The average Ryodoraku score of the patients was 33.00±14.90 (μA). In the Heart Rate Variability (HRV) test, the average Total Power (TP) and Low Frequency/High Frequency (LF/HF)) ratio was 1356.60±13 6.41(ms2) and 1.68±2.25, respectively. Conclusions: The results of this study suggest that clinicians can use Electrogastrography to enhance accuracy when diagnosing the SQD pattern.

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

Determination of Free 4-hydroxyproline with Dansylchloride by HPLC in Human Urine (소변 중 4-hydroxyproline 분석에 관한 연구)

  • Lee, Keou-Weon;Cho, Young-Bong;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.4
    • /
    • pp.282-286
    • /
    • 2002
  • Objectives : The level of 4-hydroxyproline (4-Hyp) in human urine was measured using high performance liquid chromatography (HPLC) with a fluorescence detector. This method is useful for medical examinations and investigating the radicals induced by physical, chemical, mental stresses. This method is superior to many published several methods in terms of its low cost and ability to analyze many samples. Methods : The urine from workers in a tire manufacturing company (22 male pre- and post-shift workers) and 18 office-workers as controls were analyzed. Data concerning age, the cumulative drinking amount and the cumulative smoking amount was collected with a questionnaire. The optimum applied amount of dansyl-Cl, the optimum reaction temperature and time, the recoveries and the optimum pH of the eluent and buffer were determined.4-Hyp from human urine was derivatized with dansyl-Cl (dimethylamino-naphthalene-1-sulfonyl chloride) after removing the a-amino acid by a treatment with phthalic dicarboxaldehyde (OPA) and cleaned with Bond Elut C18 column. The 4-Hyp derivatives were separated on a reversed phase column by gradient elution with a phosphate buffer (5 mmol, pH 8.0) and acetonitrile, and detected by fluorescence measurements at 340 nm (excitation) and 538 nm (emission). Results : The detection limit for the urinary free 4-Hyp was $0.364{\mu}mol/l$. The recovery rate of 4-Hyp was 99.7%, and the effective pH of the phosphate buffer and borate buffer were 3.0 and 8.0, respectively. From statistical analysis, age, drinking and smoking did not affect the urinary free 4-Hyp in both the controls and workers. The range of urinary 4-Hyp in the controls, pre-shift, and post-shift workers were 0.33-16.44, N.D-49.06, and $0.32-56.27{\mu}mol/l$. From the pared-sample t-test, the urinary 4-Hyp levels in post-shift workers ($11.82{\pm}6.73\;nmmol/mg\;Cre$) were 2-fold higher than in pre-shift workers ($5.36{\pm}5.53\;nmol;/mg\;Cre$) and controls ($4.91{\pm}4.89\;nmol;/mg\;Cre$). Conclusions : This method was developed with high sensitivity, accuracy, and precision. The present method was effectively applied to analyze the urinary free 4-Hyp in both controls and workers.

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF

Pedestrian Dead Reckoning based Position Estimation Scheme considering Pedestrian's Various Movement Type under Combat Environments (전장환경 하에서 보행자의 다양한 이동유형을 고려한 관성항법 기반의 위치인식 기법)

  • Park, SangHoon;Chae, Jongmok;Lee, Jang-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.609-617
    • /
    • 2016
  • In general, Personal Navigation Systems (PNSs) can be defined systems to acquire pedestrian positional information. GPS is an example of PNS. However, GPS can only be used where the GPS signal can be received. Pedestrian Dead Reckoning (PDR) can estimate the positional information of pedestrians using Inertial Measurement Unit (IMU). Therefore, PDR can be used for GPS-disabled areas. This paper proposes a PDR scheme considering various movement types over GPS-disabled areas as combat environments. We propose a movement distance estimation scheme and movement direction estimation scheme as pedestrian's various movement types such as walking, running and crawling using IMU. Also, we propose a fusion algorithm between GPS and PDR to mitigate the lack of accuracy of positional information at the entrance to the building. The proposed algorithm has been tested in a real test bed. In the experimental results, the proposed algorithms exhibited an average position error distance of 5.64m and position error rate in goal point of 3.41% as a pedestrian traveled 0.6km.

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.

Real-time Hand Region Detection based on Cascade using Depth Information (깊이정보를 이용한 케스케이드 방식의 실시간 손 영역 검출)

  • Joo, Sung Il;Weon, Sun Hee;Choi, Hyung Il
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.10
    • /
    • pp.713-722
    • /
    • 2013
  • This paper proposes a method of using depth information to detect the hand region in real-time based on the cascade method. In order to ensure stable and speedy detection of the hand region even under conditions of lighting changes in the test environment, this study uses only features based on depth information, and proposes a method of detecting the hand region by means of a classifier that uses boosting and cascading methods. First, in order to extract features using only depth information, we calculate the difference between the depth value at the center of the input image and the average of depth value within the segmented block, and to ensure that hand regions of all sizes will be detected, we use the central depth value and the second order linear model to predict the size of the hand region. The cascade method is applied to implement training and recognition by extracting features from the hand region. The classifier proposed in this paper maintains accuracy and enhances speed by composing each stage into a single weak classifier and obtaining the threshold value that satisfies the detection rate while exhibiting the lowest error rate to perform over-fitting training. The trained classifier is used to classify the hand region, and detects the final hand region in the final merger stage. Lastly, to verify performance, we perform quantitative and qualitative comparative analyses with various conventional AdaBoost algorithms to confirm the efficiency of the hand region detection algorithm proposed in this paper.

Research and development on image luminance meter of road tunnel internal and external (도로터널 내/외부의 영상휘도 측정기 연구개발)

  • Jang, Soon-Chul;Park, Sung-Lim;Ko, Seok-Yong;Lee, Mi-Ae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • This paper introduces the development of imaging luminance meter which measures the luminances of external/internal road tunnel. The developed imaging luminance meter complies with both L20 method and Veiling luminance method of the international standards, CIE88. In this paper the L20 method is mainly presented because most of tunnels currently adapt L20 method. The developed system has an embedded computer to operate at stand-alone. The system has a ethernet port, a heater, a fan, a defroster, a wiper and sun shielder. Compensation algorithm is applied for correcting non-linear responses to the luminance and integration time. The accuracy of measurement is less than 1% when it calibrated at the public certification institute. The developed system was also tested at the real field, road tunnel. The test results were very similar with the reference luminance meter and showed that the developed system operates well at the real field. Partial sensor saturations were happened to show the less luminance, because there were the high reflecting objects in the real field. Further study should be followed for high luminance measurement.